Literature DB >> 26438414

Impact of endobronchial coiling on segmental bronchial lumen in treated and untreated lung lobes: Correlation with changes in lung volume, clinical and pulmonary function tests.

C Kloth1, W M Thaiss2, J Hetzel3, H Ditt4, U Grosse2, K Nikolaou2, M Horger2.   

Abstract

OBJECTIVES: To assess the impact of endobronchial coiling on the segment bronchus cross-sectional area and volumes in patients with lung emphysema using quantitative chest-CT measurements.
MATERIALS AND METHODS: Thirty patients (female = 15; median age = 65.36 years) received chest-CT before and after endobronchial coiling for lung volume reduction (LVR) between January 2010 and December 2014. Thin-slice (0.6 mm) non-enhanced image data sets were acquired both at end-inspiration and end-expiration using helical technique and 120 kV/100-150 mAs. Clinical response was defined as an increase in the walking distance (Six-minute walk test; 6MWT) after LVR-therapy. Additionally, pulmonary function test (PFT) measurements were used for clinical correlation.
RESULTS: In the treated segmental bronchia, the cross-sectional lumen area showed significant reduction (p < 0.05) in inspiration and tendency towards enlargement in expiration (p > 0.05). In the ipsilateral lobes, the lumina showed no significant changes. In the contralateral lung, we found tendency towards increased cross-sectional area in inspiration (p = 0.06). Volumes of the treated segments correlated with the treated segmental bronchial lumina in expiration (r = 0.80, p < 0.001). Clinical correlation with changes in 6MWT/PFT showed a significant decrease of the inspiratory volume of the treated lobe in responders only.
CONCLUSION: Endobronchial coiling causes significant decrease in the cross-sectional area of treated segment bronchi in inspiration and a slight increase in expiration accompanied by a volume reduction. KEY POINTS: • Endobronchial coiling has indirect impact on cross-sectional area of treated segment bronchi • Volume changes of treated lobes correlate with changes in bronchial cross-sectional area • Coil-induced effects reflect their stabilizing and stiffening impact on lung parenchyma • Endobronchial coiling reduces bronchial collapsing compensating the loss of elasticity.

Entities:  

Keywords:  Chronic obstructive pulmonary disease (COPD); Computed tomography densitometry; Endobronchial coiling; High-resolution CT (HRCT); Lung volume reduction (LVR)

Mesh:

Year:  2015        PMID: 26438414     DOI: 10.1007/s00330-015-4033-4

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  19 in total

1.  Efficacy predictors of lung volume reduction with Zephyr valves in a European cohort.

Authors:  Felix J F Herth; Marc Noppen; Arschang Valipour; Sylvie Leroy; Jean-Michel Vergnon; Joachim H Ficker; Jim J Egan; Stefano Gasparini; Carlos Agusti; Debby Holmes-Higgin; Armin Ernst
Journal:  Eur Respir J       Date:  2012-01-26       Impact factor: 16.671

Review 2.  The utility of superelasticity in medicine.

Authors:  T W Duerig; A R Pelton; D Stöckel
Journal:  Biomed Mater Eng       Date:  1996       Impact factor: 1.300

3.  Accurate measurement of small airways on low-dose thoracic CT scans in smokers.

Authors:  Barbara A Lutey; Susan H Conradi; Jeffrey J Atkinson; Jie Zheng; Kenneth B Schechtman; Robert M Senior; David S Gierada
Journal:  Chest       Date:  2013-05       Impact factor: 9.410

4.  Tracheobronchomalacia: comparison between end-expiratory and dynamic expiratory CT for evaluation of central airway collapse.

Authors:  Ronaldo H Baroni; David Feller-Kopman; Mizuki Nishino; Hiroto Hatabu; Stephen H Loring; Armin Ernst; Phillip M Boiselle
Journal:  Radiology       Date:  2005-03-29       Impact factor: 11.105

5.  MR Quantitative Equilibrium Signal Mapping: A Reliable Alternative to CT in the Assessment of Emphysema in Patients with Chronic Obstructive Pulmonary Disease.

Authors:  Wei-Juan Zhang; Penny L Hubbard Cristinacce; Eva Bondesson; Lars H Nordenmark; Simon S Young; Yu-Zhen Liu; Dave Singh; Josephine H Naish; Geoffrey J M Parker
Journal:  Radiology       Date:  2015-01-07       Impact factor: 11.105

6.  Effectiveness of endobronchial coil treatment for lung volume reduction in patients with severe heterogeneous emphysema and bilateral incomplete fissures: a six-month follow-up.

Authors:  Konstantina Kontogianni; Vasiliki Gerovasili; Daniela Gompelmann; Maren Schuhmann; Claus Peter Heussel; Felix J F Herth; Ralf Eberhardt
Journal:  Respiration       Date:  2014-05-10       Impact factor: 3.580

7.  Endoscopic lung volume reduction. A European perspective.

Authors:  Daniela Gompelmann; Ralf Eberhardt; Felix J F Herth
Journal:  Ann Am Thorac Soc       Date:  2013-12

8.  Description of a multidimensional classification system for patients with expiratory central airway collapse.

Authors:  Septimiu D Murgu; Henri G Colt
Journal:  Respirology       Date:  2007-07       Impact factor: 6.424

Review 9.  Effectiveness of bronchoscopic lung volume reduction using unilateral endobronchial valve: a systematic review and meta-analysis.

Authors:  Miyoung Choi; Worl Suk Lee; Min Lee; Kyeongman Jeon; Seungsoo Sheen; Sanghoon Jheon; Young Sam Kim
Journal:  Int J Chron Obstruct Pulmon Dis       Date:  2015-03-31

10.  Lung volume reduction coil treatment for patients with severe emphysema: a European multicentre trial.

Authors:  Gaëtan Deslee; Karin Klooster; Martin Hetzel; Franz Stanzel; Romain Kessler; Charles-Hugo Marquette; Christian Witt; Stefan Blaas; Wolfgang Gesierich; Felix J F Herth; Juergen Hetzel; Eva M van Rikxoort; Dirk-Jan Slebos
Journal:  Thorax       Date:  2014-06-02       Impact factor: 9.139

View more
  4 in total

Review 1.  Lung volume reduction with endobronchial coils for patients with emphysema.

Authors:  Jorrit B A Welling; Dirk-Jan Slebos
Journal:  J Thorac Dis       Date:  2018-08       Impact factor: 2.895

2.  Protocol of a Randomized Controlled Study of the PneumRx Endobronchial Coil System versus Standard-of-Care Medical Management in the Treatment of Subjects with Severe Emphysema (ELEVATE).

Authors:  Felix J F Herth; Dirk-Jan Slebos; Pallav L Shah; Martin Hetzel; Gerald Schmid-Bindert; Adam S LaPrad; Gaëtan Deslée; Arschang Valipour
Journal:  Respiration       Date:  2019-11-19       Impact factor: 3.580

3.  Prediction of response to endobronchial coiling based on morphologic emphysema characterization of the lung lobe to be treated and the ipsilateral non-treated lobe as well as on functional computed tomography-data: correlation with clinical and pulmonary function.

Authors:  Christopher Kloth; Wolfgang Maximilian Thaiss; Jan Fritz; Konstantin Nikolaou; Meinrad Beer; Jürgen Hetzel; Sorin Dumitru Ioanoviciu; Marius Horger
Journal:  J Thorac Dis       Date:  2019-01       Impact factor: 2.895

4.  Endobronchial coils for emphysema: Dual mechanism of action on lobar residual volume reduction.

Authors:  Jorine E Hartman; Pallav L Shah; Frank Sciurba; Felix J F Herth; Dirk-Jan Slebos
Journal:  Respirology       Date:  2020-04-08       Impact factor: 6.424

  4 in total