Literature DB >> 26438090

[Ultrasound elastography].

R S Goertz1.   

Abstract

Noninvasive, ultrasound-based methods for visualizing and measuring tissue elasticity are becoming more and more common in routine practice. Using hepatic shear wave elastography, cut-off levels can help to detect the degree of relevant fibrosis (F ≥ 2) with a diagnostic accuracy using the area under the reader operating characteristic (AUROC) of 87 % and cirrhosis (F = 4, AUROC 93 %). Normal values virtually exclude liver cirrhosis (negative predictive value up to 97 %) and high shear wave velocities predict complications in the course of primary sclerosing cholangitis, liver cirrhosis and chronic hepatitis B or C. Elastography is of no relevant help in the differentiation of the dignity of hepatic lesions. Concerning thyroid or breast lesions, low shear wave velocities are indicative of benign lesions and in contrast, high velocities of malignant lesions. A differentiation between benign and malignant thyroid nodules is performed by elastography with a sensitivity of 89 % and a specificity of 82 %. In breast lesions a differentiation of nodes can be improved with elastography compared to B-mode ultrasound alone with a sensitivity of 97 % and a specificity of 83 %. Invasive biopsy punctures can therefore be specifically performed or can be omitted. Due to several influencing factors, in particular during liver elastography, the measurements need to be interpreted in the clinical context. In summary, ultrasound-based elastography provides helpful information for the detection of hepatic fibrosis and for further characterization of thyroid or breast lesions in addition to classical techniques, such as B-mode imaging and color Doppler.

Entities:  

Keywords:  Breast; Fibrosis; Liver; Shear wave velocity; Thyroid gland

Mesh:

Year:  2015        PMID: 26438090     DOI: 10.1007/s00117-015-0028-z

Source DB:  PubMed          Journal:  Radiologe        ISSN: 0033-832X            Impact factor:   0.635


  41 in total

1.  Characterization of focal liver lesions (FLL) with acoustic radiation force impulse (ARFI) elastometry.

Authors:  R Heide; D Strobel; T Bernatik; R S Goertz
Journal:  Ultraschall Med       Date:  2010-07-22       Impact factor: 6.548

2.  Shear-wave elastography improves the specificity of breast US: the BE1 multinational study of 939 masses.

Authors:  Wendie A Berg; David O Cosgrove; Caroline J Doré; Fritz K W Schäfer; William E Svensson; Regina J Hooley; Ralf Ohlinger; Ellen B Mendelson; Catherine Balu-Maestro; Martina Locatelli; Christophe Tourasse; Barbara C Cavanaugh; Valérie Juhan; A Thomas Stavros; Anne Tardivon; Joel Gay; Jean-Pierre Henry; Claude Cohen-Bacrie
Journal:  Radiology       Date:  2012-02       Impact factor: 11.105

3.  Unclear focal liver lesions in contrast-enhanced ultrasonography--lessons to be learned from the DEGUM multicenter study for the characterization of liver tumors.

Authors:  T Bernatik; K Seitz; W Blank; A Schuler; C F Dietrich; D Strobel
Journal:  Ultraschall Med       Date:  2010-08-25       Impact factor: 6.548

4.  [Summary of the updated stage 3 guideline for early detection of breast cancer in Germany 2008].

Authors:  U-S Albert; H Altland; V Duda; J Engel; M Geraedts; S Heywang-Köbrunner; D Hölzel; E Kalbheim; M Koller; K König; R Kreienberg; T Kühn; A Lebeau; I Nass-Griegoleit; W Schlake; R Schmutzler; I Schreer; H Schulte; R Schulz-Wendtland; U Wagner; I Kopp
Journal:  Rofo       Date:  2008-05

5.  EASL Clinical Practice Guidelines: management of hepatitis C virus infection.

Authors: 
Journal:  J Hepatol       Date:  2011-03-01       Impact factor: 25.083

6.  ARFI cut-off values and significance of standard deviation for liver fibrosis staging in patients with chronic liver disease.

Authors:  Ruediger S Goertz; Joerg Sturm; Lukas Pfeifer; Dane Wildner; David L Wachter; Markus F Neurath; Deike Strobel
Journal:  Ann Hepatol       Date:  2013 Nov-Dec       Impact factor: 2.400

7.  Magnetic resonance elastography and acoustic radiation force impulse for staging hepatic fibrosis: a meta-analysis.

Authors:  Yang Guo; Sudharshan Parthasarathy; Preeya Goyal; Robert J McCarthy; Andrew C Larson; Frank H Miller
Journal:  Abdom Imaging       Date:  2015-04

8.  WFUMB guidelines and recommendations for clinical use of ultrasound elastography: Part 3: liver.

Authors:  Giovanna Ferraioli; Carlo Filice; Laurent Castera; Byung Ihn Choi; Ioan Sporea; Stephanie R Wilson; David Cosgrove; Christoph F Dietrich; Dominique Amy; Jeffrey C Bamber; Richard Barr; Yi-Hong Chou; Hong Ding; Andre Farrokh; Mireen Friedrich-Rust; Timothy J Hall; Kazutaka Nakashima; Kathryn R Nightingale; Mark L Palmeri; Fritz Schafer; Tsuyoshi Shiina; Shinichi Suzuki; Masatoshi Kudo
Journal:  Ultrasound Med Biol       Date:  2015-03-20       Impact factor: 2.998

9.  Liver fibrosis in viral hepatitis: noninvasive assessment with acoustic radiation force impulse imaging versus transient elastography.

Authors:  Mireen Friedrich-Rust; Katrin Wunder; Susanne Kriener; Fariba Sotoudeh; Swantje Richter; Joerg Bojunga; Eva Herrmann; Thierry Poynard; Christoph F Dietrich; Johannes Vermehren; Stefan Zeuzem; Christoph Sarrazin
Journal:  Radiology       Date:  2009-08       Impact factor: 11.105

10.  Liver stiffness assessed by acoustic radiation force impulse (ARFI) technology is considerably increased in patients with cholestasis.

Authors:  L Pfeifer; D Strobel; M F Neurath; D Wildner
Journal:  Ultraschall Med       Date:  2014-05-13       Impact factor: 6.548

View more
  1 in total

1.  Comparative study on the diagnostic values of different ultrasound technologies for malignant thyroid nodules.

Authors:  Xiao-Zhu Jin; Wei-Wei Lu; Hai-Feng Zhang; Yuan-Yuan Yan; Xiao-Le Gu
Journal:  Oncol Lett       Date:  2018-05-14       Impact factor: 2.967

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.