Literature DB >> 26433352

Electrochemical lateral flow immunosensor for detection and quantification of dengue NS1 protein.

Prima Dewi Sinawang1, Varun Rai1, Rodica E Ionescu2, Robert S Marks3.   

Abstract

An Electrochemical Lateral Flow Immunosensor (ELFI) is developed combining screen-printed gold electrodes (SPGE) enabling quantification together with the convenience of a lateral flow test strip. A cellulose glassy fiber paper conjugate pad retains the marker immunoelectroactive nanobeads which will bind to the target analyte of interest. The specific immunorecognition event continues to occur along the lateral flow bed until reaching the SPGE-capture antibodies at the end of the cellulosic lateral flow strip. The rationale of the immunoassay consists in the analyte antigen NS1 protein being captured selectively and specifically by the dengue NS1 antibody conjugated onto the immunonanobeads thus forming an immunocomplex. With the aid of a running buffer, the immunocomplexes flow and reach the immuno-conjugated electrode surface and form specific sandwich-type detection due to specific, molecular recognition, while unbound beads move along past the electrodes. The successful sandwich immunocomplex formation is then recorded electrochemically. Specific detection of NS1 is translated into an electrochemical signal contributed by a redox label present on the bead-immobilized detection dengue NS1 antibody while a proportional increase of faradic current is observed with increase in analyte NS1 protein concentration. The first generation ELFI prototype is simply assembled in a cassette and successfully demonstrates wide linear range over a concentration range of 1-25 ng/mL with an ultrasensitive detection limit of 0.5 ng/mL for the qualitative and quantitative detection of analyte dengue NS1 protein.
Copyright © 2015 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Cellulose paper; Cyclic voltammetry; Dengue virus DENV NS1 protein; Electrochemical impedance spectroscopy (EIS); Electrochemical lateral flow immunosensor; Gold nanoparticles (AuNPs)

Mesh:

Substances:

Year:  2015        PMID: 26433352     DOI: 10.1016/j.bios.2015.09.048

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  19 in total

Review 1.  Dengue virus: a review on advances in detection and trends - from conventional methods to novel biosensors.

Authors:  Reza Eivazzadeh-Keihan; Paria Pashazadeh-Panahi; Tohid Mahmoudi; Karim Khanmohammadi Chenab; Behzad Baradaran; Mahmoud Hashemzaei; Fateme Radinekiyan; Ahad Mokhtarzadeh; Ali Maleki
Journal:  Mikrochim Acta       Date:  2019-05-04       Impact factor: 5.833

Review 2.  Recent Advances in Electrochemical Immunosensors.

Authors:  Benoît Piro; Steeve Reisberg
Journal:  Sensors (Basel)       Date:  2017-04-07       Impact factor: 3.576

3.  Hybrid paper and 3D-printed microfluidic device for electrochemical detection of Ag nanoparticle labels.

Authors:  Charuksha Walgama; Michael P Nguyen; Lisa M Boatner; Ian Richards; Richard M Crooks
Journal:  Lab Chip       Date:  2020-05-05       Impact factor: 6.799

4.  Tapered lateral flow immunoassay based point-of-care diagnostic device for ultrasensitive colorimetric detection of dengue NS1.

Authors:  Sanjay Kumar; Pulak Bhushan; Vinay Krishna; Shantanu Bhattacharya
Journal:  Biomicrofluidics       Date:  2018-05-14       Impact factor: 2.800

Review 5.  Tutorial: design and fabrication of nanoparticle-based lateral-flow immunoassays.

Authors:  Claudio Parolo; Amadeo Sena-Torralba; José Francisco Bergua; Enric Calucho; Celia Fuentes-Chust; Liming Hu; Lourdes Rivas; Ruslan Álvarez-Diduk; Emily P Nguyen; Stefano Cinti; Daniel Quesada-González; Arben Merkoçi
Journal:  Nat Protoc       Date:  2020-10-23       Impact factor: 13.491

Review 6.  Biosensing strategies for the electrochemical detection of viruses and viral diseases - A review.

Authors:  Laís Canniatti Brazaca; Pãmyla Layene Dos Santos; Paulo Roberto de Oliveira; Diego Pessoa Rocha; Jéssica Santos Stefano; Cristiane Kalinke; Rodrigo Alejandro Abarza Muñoz; Juliano Alves Bonacin; Bruno Campos Janegitz; Emanuel Carrilho
Journal:  Anal Chim Acta       Date:  2021-03-12       Impact factor: 6.911

Review 7.  Flavivirus NS1: a multifaceted enigmatic viral protein.

Authors:  Meghana Rastogi; Nikhil Sharma; Sunit Kumar Singh
Journal:  Virol J       Date:  2016-07-29       Impact factor: 4.099

Review 8.  Point-of-Care-Testing in Acute Stroke Management: An Unmet Need Ripe for Technological Harvest.

Authors:  Dorin Harpaz; Evgeni Eltzov; Raymond C S Seet; Robert S Marks; Alfred I Y Tok
Journal:  Biosensors (Basel)       Date:  2017-08-03

9.  Development of peptide biosensor for the detection of dengue fever biomarker, nonstructural 1.

Authors:  Ji Hong Kim; Chae Hwan Cho; Myung Yi Ryu; Jong-Gil Kim; Sei-Jung Lee; Tae Jung Park; Jong Pil Park
Journal:  PLoS One       Date:  2019-09-25       Impact factor: 3.240

Review 10.  Ultrasensitive detection of pathogenic viruses with electrochemical biosensor: State of the art.

Authors:  M Z H Khan; M R Hasan; S I Hossain; M S Ahommed; M Daizy
Journal:  Biosens Bioelectron       Date:  2020-07-16       Impact factor: 10.618

View more