| Literature DB >> 26430495 |
Sarath Babu Devarakonda1, Boochi Babu Mannuva1, Rajasekhar Durgaprasad1, Vanajakshamma Velam1, Vidya Sagar Akula1, Latheef Kasala1.
Abstract
INTRODUCTION: Percutaneous transvenous mitral commissurotomy (PTMC) is a safe and effective procedure for relief of severe mitral stenosis. PTMC is being done widely and many transseptal procedures requiring large diameter catheters, sheaths are becoming popular. The knowledge of iatrogenic atrial septal defect (iASD) is vital. This study assessed the use of real-time 3D echocardiography (RT3DE) and incidence of iASD in a cohort of patients undergoing transseptal catheterization during PTMC.Entities:
Keywords: PTMC; RT3DE; iASD
Year: 2015 PMID: 26430495 PMCID: PMC4586604 DOI: 10.15171/jcvtr.2015.20
Source DB: PubMed Journal: J Cardiovasc Thorac Res ISSN: 2008-5117
Figure 1
Figure 2
Demographic and Echocardiographic Parameters
|
|
|
| Age (y) | |
| Mean ± SD | 35.21 ± 10.26 |
| Range | 13-61 |
| Sex | |
| Males | 36 (32.72%) |
| Females | 74 (67.27%) |
| Height (cm) | |
| Mean ± SD | 156.54± 9.47 |
| Range | 130 to 180 |
| Weight (kg) | |
| Mean ± SD | 49.90 ± 10.78 |
| Range | 21 to 75 |
| Previous PTMC | 9 (8.10%) |
| Previous OMV/CMV | 2 (1.8%) |
| Atrial Fibrillation | 11 (10%) |
| LVEF (%) | |
| Mean±SD | 60.15± 5.75 |
| Range | 42-70 |
| LA size (mm) | |
| Mean ± SD | 45.55 ± 6.31 |
| Range | 33 to 65 |
| RVSP (mm) | |
| Mean±SD | 53.03 ± 24.53 |
| Range | 16-130 |
| Wilkins Score | |
| Mean±SD | 7.09 ± 1.21 |
| Range | 5 to 10 |
| TR Grade | |
| Trivial TR {1+} | 25 (22.7%) |
| Mild TR {2+} | 56 (50.9%) |
| Moderate TR {3+} | 17 (15.5%) |
|
Severe TR {4+} | 12 (10.9%) |
Abbreviations: SD, standard deviation; PTMC, percutaneous transvenous mitral commissurotomy; OMC, open mitral commissurotomy; CMC, closed mitral commissurotomy; LVEF, left ventricular ejection fraction; LA, left Atrium; RVSP, right ventricular systolic pressure; TR, tricuspid regurgitation.
iASD Detection by 2DE; 3D Color, 3D Zoom, 3D Full Volume and 3D Live
|
|
|
| |
|
|
| ||
| 3D color | 16 | 94 | 85.45 |
| 3D zoom | 28 | 82 | 74.55 |
| 3D full volume | 20 | 90 | 81.82 |
| 3D Live | 22 | 88 | 80.00 |
| 2DE | 36 | 74 | 67.27 |
Cochran’s Q test= 40.5333, n = 110, df = 4, P < .001
Figure 3
Passing and Bablok regression iASD by RT3DE and 2D
|
| |
| Systematic differences | |
| Intercept A | 1.6000 |
| 95% CI | 1.1000 to 2.1200 |
| Proportional differences | |
| Slope B | 1.0000 |
| 95% CI | 0.9000 to 1.0909 |
| Random differences | |
| Residual standard deviation (RSD) | 0.7990 |
| ± 1.96 RSD Interval | -1.5661 to 1.5661 |
| Linear model validity | |
| Cusum test for linearity | No significant deviation from linearity (P = .20) |
Analysis of the Reliability of Measurements by RT3DE
| No. of Subjects (n) | 110 | |
| No. of raters (k) | 2 | |
| Model |
The same raters for all subjects. | |
| Type | Consistency | |
| Measurements |
DIAMETER RT3DE | |
| Intraclass correlation coefficient | ||
| Intraclass correlationa | 95% CI | |
| Single measuresb | 0.9183 | 0.8830 to 0.9433 |
| Average measuresc | 0.9574 | 0.9379 to 0.9708 |
a The degree of consistency among measurements; b Estimates the reliability of single ratings; c Estimates the reliability of averages of k ratings.
iASD (RT3DE) correlation with demographic, Procedural (Cath) and echocardiographic parametersa
|
|
|
|
|
| Age (y, mean) | Yes | 35.77 | .19 |
| No | 32.00 | ||
| Height (cm, mean) | Yes | 157.34 | .03b |
| No | 151.88 | ||
| Weight (kg, mean) | Yes | 49.91 | .98 |
| No | 49.88 | ||
| EF (%) | Yes | 60.33 | .44 |
| No | 59.13 | ||
| Pre-LVEDP (mm Hg) | Yes | 5.70 | .29 |
| No | 5.00 | ||
| Post-LVEDP(mm Hg) | Yes | 8.99 | .01b |
| No | 6.94 | ||
| Pre-A (mm Hg) | Yes | 23.95 | .61 |
| No | 22.56 | ||
| Post-A (mm Hg) | Yes | 13.45 | .67 |
| No | 12.69 | ||
| Pre-V(mm Hg) | Yes | 28.74 | <.0001b |
| No | 18.94 | ||
| Post-V(mm Hg) | Yes | 15.41 | .007b |
| No | 10.81 | ||
| Pre-M (mm Hg) | Yes | 21.55 | .001b |
| No | 15.38 | ||
| Post-M (mm Hg) | Yes | 10.66 | .01b |
| No | 7.75 | ||
| Inflations (no.) | Yes | 1.07 | .32 |
| No | 1.00 | ||
| Inflation pressure (mm Hg) | Yes | 24.27 | .27 |
| No | 24.06 | ||
| LA (mm) | Yes | 45.77 | .03b |
| No | 42.25 | ||
| Pre-MVA (mm) | Yes | 0.82 | .62 |
| No | 0.84 | ||
| Post-MVA (mm) | Yes | 1.73 | .01b |
| No | 1.85 | ||
| MVA Change (mm) | Yes | 0.90 | .06b |
| No | 1.00 | ||
| Wilkins score | Yes | 7.27 | .004b |
| No | 6.31 | ||
| RVSP (mm) | Yes | 54.77 | .07 |
| No | 42.81 |
a Postprocedure; b Indicates a significant P value (P < .05)
iASD on Follow up by RT3DE and 2DE
|
|
|
|
|
| 3D Color | |||
| Yes | 94 (85.5%) | 61 (55.5%) | 21 (19.09%) |
| No | 16 (14.5%) | 49 (44.5%) | 89 (80.90%) |
| 3D Full Volume | |||
| Yes | 90 (81.8%) | 61 (55.5%) | 21 (19.09%) |
| No | 20 (18.2%) | 49 (44.5%) | 89 (80.90%) |
| 3D Live | |||
| Yes | 88 (80%) | 57 (51.8%) | 16 (14.5%) |
| No | 22 (20%) | 53 (48.2) | 94 (85.5%) |
| 3D Zoom | |||
| Yes | 82 (74.5%) | 49 (44.5%) | 21 (19.1%) |
| No | 28 (25.5%) | 61 (55.5%) | 89 (80.9%) |
| 2D Echo | |||
| Yes | 74 (67.3%) | 45 (40.9%) | 11 (10%) |
| No | 36 (32.7%) | 65 (59.1) | 99 (90%) |
Abbreviations: iASD, iatrogenic atrial septal defect; RT3DE, real time three dimensional echocardiography; 2DE, two dimensional echocardiography.
Follow up of iASD in Previous PTMC Group
|
|
|
|
|
|
|
|
| Postprocedure | ||||||
| No | 16 (14.5%) | 0 (0%) | .16 | 16 | 0 | .16 |
| Yes | 83 (75.5%) | 11 (10%) | 83 | 11 | ||
| 6 months | ||||||
| No | 49 (44.5%) | 0 (0%) | .01a | 49 | 0 | .02a |
| Yes | 50 (45.5%) | 11 (10%) | 50 | 11 | ||
| 1 year | ||||||
| No | 69 (62.7%) | 5 (4.5%) | .10 | 72 | 2 | <.0001a |
| Yes | 30 (2.3%) | 6 (5.5%) | 27 | 9 |
Abbreviations: AF, atrial fibrillation; PTMC; percutaneous transvenous mitral commissurotomy.
a Indicates a significant P value (P < .05)
Comparison With Previous Studies
|
|
|
|
|
|
|
Yoshida et al[ | PBMV; 14-Fr septal dilator | TEE, TTE, and oximetry | 15 | 87% postprocedure iASDs day 1; 73% at 1 week, 47% at 1 month, 20% at 6 months by TEE |
|
Ishikura et al[ | PBMV; 14-Fr septal dilator | TTE | 46 | 15.2% postprocedure iASDs on day 1; 6.5% at 3 months; 4.3% at 12 months; iASD directly correlated to longer procedure time |
|
Cequier et al[ | PBMV single (2 patients) or double balloon (66 patients) | Venovenous indicator dilution and oximetry | 68 |
62% iASDs postprocedure; iASD present in 48% of 33 patients that had follow-up at 6 months (24% of initial 68 patients); |
|
Casale et al[ | PBMV single (n=27) or double balloon (n=123); 8-mm dilating atrial balloon, | Oximetry, TTE, and/or operative findings | 150 |
19% iASDs at time of procedure; 41% of iASDs were persistent in those that had 10-month follow-up (6% of initial 150 patients); |
|
Hammerstingl et al.[ | PVI/atrial fibrillation ablation; 8-Fr sheaths | TEE with Doppler or Contrast | 42 | 19% iASDs at 9 months; iASD with RLS associated with preprocedure increased PAP and single TS puncture |
|
Liu et al[ | Diagnostic, 6 Fr; RFA, 7 Fr; PBMV, 14-Fr catheter | Oximetry, TTE, and TEE with color Doppler | 176 | All iASDS were after PBMV; iASD incidence 19% and 15% at 6 and 18 months, respectively for all TS procedures; iASDs associated with smaller MV area, higher transmitral gradient, and PAP |
|
Rillig et al[ | PVI/AF, double TS puncture; two 8-Fr sheaths | TEE with color Doppler or contrast | 31 | 87% iASDs day 1; 3.7% at 3, 6, 12 months |
|
Manjunath et al[ | PTMC | TEE with color Doppler | 209 | Mean diameter of the iASD by TEE was 4.47 ± 1.7 mm; most common site of septal puncture was the inferior vena caval side; residual ASD was seen in 11 patients (8.7%) at 6-months |
|
Smith et al[ |
MitraClip | TTE with color Doppler | 52 | Mean diameter was 6.0 ± 2.3 mm; At 6 months and 12 months, iASDs were identified in 27% significant difference in TR grade; persistent MR >2+ was more significant in the iASD group |
| Present study | PTMC | RT3DE 2DTTE | 110 |
85% iASD post procedure, 56% at 6 month, 19% at 1yr follow up.
|