Literature DB >> 2598418

Assessment of left-to-right atrial shunting after percutaneous mitral valvuloplasty by transesophageal color Doppler flow-mapping.

K Yoshida1, J Yoshikawa, T Akasaka, Y Yamaura, M Shakudo, T Hozumi, T Fukaya.   

Abstract

To evaluate left-to-right shunts after percutaneous balloon mitral valvuloplasty, we studied 15 consecutive patients by using transesophageal color Doppler flow-imaging system. Transesophageal color Doppler examinations were performed five times in each patient (before valvuloplasty and 1 day, 1 week, 1 month, and 6 months after valvuloplasty). No shunt flow was observed before valvuloplasty. On 1 day after mitral valvuloplasty, transesophageal color Doppler echocardiography demonstrated left-to-right shunts in 13 (87%) of 15 patients. However, a significant oxygen step-up was present in the right heart in only one patient. The mean diameter of the interatrial septal defect detected by transesophageal two-dimensional echocardiography was 1.8 +/- 1.0 mm. The mean velocity of left-to-right shunting flow measured by high-pulse repetition frequency Doppler technique was 0.83 +/- 0.38 m/sec. One week after the procedure, left-to-right shunt flow was detected in 11 (73%) patients. One month after valvuloplasty, left-to-right shunting flow was detected in seven (47%) of 15 patients. There was a significant decrease in the diameter of an interatrial septal defect between 1 day and 1 week (p less than 0.01), between 1 week and 1 month (p less than 0.01), and between 1 month and 6 months (p less than 0.05). Six months after valvuloplasty, left-to-right shunting flow remained in three (20%) patients. By using transthoracic color Doppler echocardiography, we detected left-to-right shunting flow in two patients on 1 day after the procedure.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1989        PMID: 2598418     DOI: 10.1161/01.cir.80.6.1521

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  7 in total

1.  Long-term follow-up of iatrogenic atrial septal defect: after percutaneous mitral balloon valvuloplasty.

Authors:  Sule Korkmaz; Burcu Demirkan; Yesim Guray; Mehmet Birhan Yilmaz; Hatice Sasmaz
Journal:  Tex Heart Inst J       Date:  2011

2.  Catheter ablation of ventricular tachycardia associated with remote myocardial infarction: utility of the atrial transseptal approach.

Authors:  D Schwartzman; D J Callans; C D Gottlieb; F E Marchlinski
Journal:  J Interv Card Electrophysiol       Date:  1997-02       Impact factor: 1.900

3.  Persistent iatrogenic atrial septal defect after pulmonary vein isolation : incidence and clinical implications.

Authors:  Andreas Rillig; Udo Meyerfeldt; Ralf Birkemeyer; Fabian Treusch; Markus Kunze; Werner Jung
Journal:  J Interv Card Electrophysiol       Date:  2008-05-07       Impact factor: 1.900

4.  Real Time 3D Echocardiographic Evaluation of Iatrogenic Atrial Septal Defects After Percutaneous Transvenous Mitral Commissurotomy.

Authors:  Sarath Babu Devarakonda; Boochi Babu Mannuva; Rajasekhar Durgaprasad; Vanajakshamma Velam; Vidya Sagar Akula; Latheef Kasala
Journal:  J Cardiovasc Thorac Res       Date:  2015

Review 5.  Haemodynamic and functional consequences of the iatrogenic atrial septal defect following Mitraclip therapy.

Authors:  E A Hart; K Zwart; A J Teske; M Voskuil; P R Stella; S A J Chamuleau; A O Kraaijeveld
Journal:  Neth Heart J       Date:  2017-02       Impact factor: 2.380

6.  Direct visualization of an iatrogenic septal defect in a reanimated human heart.

Authors:  Stephen A Howard; Ryan P Goff; David G Benditt; Paul A Iaizzo
Journal:  HeartRhythm Case Rep       Date:  2015-09-25

7.  Editorial: Percutaneous mitral valvotomy: Balloon made in Japan still dominates the world.

Authors:  Nozomi Watanabe
Journal:  J Cardiol Cases       Date:  2016-04-08
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.