Literature DB >> 26420695

Endoscopic closure of a refractory gastrocutaneous fistula using a novel over-the-scope Padlock clip following de-epithelialisation of the fistula tract.

Arun Abraham1, Dipesh H Vasant2, John McLaughlin2, Peter A Paine2.   

Abstract

Persistent gastrocutaneous fistula (GCF) is a difficult to manage complication following gastrostomy tube removal, with leakage resulting in distressing sequelae including cutaneous injury, infection and dehydration. Many such patients are high-risk for invasive surgery and, to date, endoscopic closure techniques, including clipping systems, have limitations. We present the case of a 62-year-old woman with persistently leaking GCF 6 months postgastrostomy tube removal, despite maximal antisecretory therapy and postpyloric feeding, and describe failed attempted endoscopic closure with conventional clips. Treatment options were discussed and informed consent was given for an attempt at endoscopic closure using a novel radial closure device ('Padlock clip') combined with surgical de-epithelialisation, with the understanding that this device has never previously been used in this setting. At follow-up 2 weeks postprocedure, the patient was asymptomatic with complete healing of the GCF. This approach has advantages over other endoscopic closure techniques and can be considered as an alternative approach to GCF closure. 2015 BMJ Publishing Group Ltd.

Entities:  

Mesh:

Year:  2015        PMID: 26420695      PMCID: PMC4593293          DOI: 10.1136/bcr-2015-211242

Source DB:  PubMed          Journal:  BMJ Case Rep        ISSN: 1757-790X


  17 in total

1.  Over-the-scope clip to close a fistula after removing a percutaneous endoscopic gastrostomy tube.

Authors:  J K Turner; J J Hurley; I Ketchell; S Dolwani
Journal:  Endoscopy       Date:  2010-09-15       Impact factor: 10.093

2.  Gastrotomy closure with the lock-it system and the Padlock-G clip: a survival study in a porcine model.

Authors:  David J Desilets; John R Romanelli; David B Earle; Christopher N Chapman
Journal:  J Laparoendosc Adv Surg Tech A       Date:  2010-10       Impact factor: 1.878

3.  Natural orifice transluminal endoscopic surgery gastrotomy closure in porcine explants with the Padlock-G clip using the Lock-It system.

Authors:  J R Romanelli; D J Desilets; D B Earle
Journal:  Endoscopy       Date:  2010-03-30       Impact factor: 10.093

4.  Combined endoscopic cautery and clip closure of chronic gastrocutaneous fistulas.

Authors:  Jonathan E Teitelbaum; Steven A Gorcey; Victor L Fox
Journal:  Gastrointest Endosc       Date:  2005-09       Impact factor: 9.427

5.  Persistent gastrocutaneous fistula after percutaneous gastrostomy tube removal.

Authors:  S Peter; M Geyer; C Beglinger
Journal:  Endoscopy       Date:  2006-05       Impact factor: 10.093

6.  Endoscopically assisted suturing of a persistent gastrocutaneous fistula by using a site closure device.

Authors:  Dipesh H Vasant; Arun Abraham; Peter A Paine
Journal:  Gastrointest Endosc       Date:  2013-09       Impact factor: 9.427

7.  Closure of persistent gastrocutaneous postpercutaneous endoscopic gastrostomy fistula by simple percutaneous suturing with endoscopic assist.

Authors:  Takako Tasaki; Yoshitatsu Arakaki; Kazunari Murakami; Toshio Fujioka
Journal:  Gastrointest Endosc       Date:  2012-09       Impact factor: 9.427

8.  The over-the-scope clip system--a novel technique for gastrocutaneous fistula closure: the first North American experience.

Authors:  Truptesh H Kothari; Gregory Haber; Niket Sonpal; Nithin Karanth
Journal:  Can J Gastroenterol       Date:  2012-04       Impact factor: 3.522

9.  Incidence and predictors of gastrocutaneous fistula in the pediatric patient.

Authors:  Ioana Bratu; Aamir Bharmal
Journal:  ISRN Gastroenterol       Date:  2010-12-01

10.  Endoscopic treatment of a gastrocutaneous fistula using the over-the-scope-clip system: a case report.

Authors:  Georgios Kouklakis; Petros Zezos; Nikolaos Liratzopoulos; Anthia Gatopoulou; Anastasia Oikonomou; Michail Pitiakoudis; Eleni Efremidou; Constantinos Simopoulos
Journal:  Diagn Ther Endosc       Date:  2011-05-29
View more
  2 in total

1.  Over-the-Scope Clip Closure of Persistent Gastrocutaneous Fistula After Percutaneous Endoscopic Gastrostomy Tube Removal: A Report of Two Cases.

Authors:  Shigenori Masaki; Keishi Yamada
Journal:  Cureus       Date:  2021-02-07

Review 2.  Prevention and management of major complications in percutaneous endoscopic gastrostomy.

Authors:  Kurt Boeykens; Ivo Duysburgh
Journal:  BMJ Open Gastroenterol       Date:  2021-05
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.