Literature DB >> 26419895

Validation of a German version of the International Hip Outcome Tool (G-iHOT33) according to the COSMIN checklist: how much improvement is clinically relevant?

Florian Baumann1, Johannes Weber2, Florian Zeman3, Michael Müller2, Matthias Lahner4, Michael Nerlich2, Stefan Fickert5,6.   

Abstract

PURPOSE: The evaluation of the subjective health-related quality of life is especially for young, active patients with hip joint disorders important. The MAHORN study group has recently developed the "International Hip Outcome Tool" (iHOT33), a self-administered patient-reported outcome tool, which includes questions on the patient's symptoms, functional and sports limitations as well as social, emotional, and occupational limitations. The purpose of this study was to adapt and validate a German version of the iHOT33 according to the COSMIN checklist.
METHODS: To validate the G-iHOT33, we conducted a prospective multicenter cohort study on patients with hip disorders and a score ≥4 on the modified Tegner Activity Scale. The patients completed the G-iHOT33 questionnaire twice at intervals of at least 2 weeks. In addition, we recorded the Hip Outcome Score (HOS), a modified Tegner Activity Scale (TAS), the EuroQol-5D (EQ5-D), and a subjective assessment of the limitations. Evaluation of psychometric properties was conducted following the COSMIN checklist for validation of health status measurement instruments. The methodical testing for reliability included internal consistency, test-retest reliability, and measurement error. For testing of validity, we analyzed construct validity, hypotheses testing, interpretability, and responsiveness.
RESULTS: Between December 2013 and December 2014, eighty-three consecutive patients completed both questionnaires and were available for data analysis. Cronbach's α was 0.97 (95% CI 0.96, 0.99) confirming internal consistency and test-retest reliability of the G-iHOT-33 was high with an ICC = 0.88 (95% CI 0.80, 0.99). All a priori hypotheses were confirmed, further, no floor- or ceiling-effects occurred. The G-iHOT33 showed good responsiveness with a minimal important change (MIC) of 10 points.
CONCLUSIONS: The German translation of the iHOT-33 (G-iHOT-33) is a viable tool for the evaluation of active patients with a hip disorder. Following the complete COSMIN checklist, we could prove that G-iHOT33 is a reliable, valid, and responsive PRO measurement tool. We could show that the minimal important change, a change of health condition the patient discerns is 10 points in the G-iHOT33 scale. This is the first study providing results on psychometric properties of the iHOT33 subscales. Level of evidence 1b validating cohort study.

Entities:  

Keywords:  COSMIN checklist; Femoro-acetabular impingement syndrome (FAI); German International Hip Outcome Tool 33 (G-iHOT33); Hip arthroscopy; Patient-reported outcome (PRO); Responsiveness

Mesh:

Year:  2015        PMID: 26419895     DOI: 10.1007/s00402-015-2336-1

Source DB:  PubMed          Journal:  Arch Orthop Trauma Surg        ISSN: 0936-8051            Impact factor:   3.067


  9 in total

1.  Amorphous calcium deposits of the hip joint: current observations and state of the scientific discussion.

Authors:  Solveig Lerch; Alexander Zimmerer; Patrik Puljic; Oliver Rühmann
Journal:  Arch Orthop Trauma Surg       Date:  2022-09-08       Impact factor: 2.928

2.  Cross-cultural adaptation, and validation of the Turkish version of the Nonarthritic Hip Score.

Authors:  Zeynep Hazar Kanık; Uğur Sözlü; Sevim Beyza Ölmez; Selda Başar; Ulunay Kanatlı
Journal:  Acta Orthop Traumatol Turc       Date:  2020-07       Impact factor: 1.511

3.  A Registry for Evaluation of Efficiency and Safety of Surgical Treatment of Cartilage Defects: The German Cartilage Registry (KnorpelRegister DGOU).

Authors:  Julia Maurer; Birgit Grotejohann; Carolin Jenkner; Carla Schneider; Thomas Flury; Adrian Tassoni; Peter Angele; Jürgen Fritz; Dirk Albrecht; Philipp Niemeyer
Journal:  JMIR Res Protoc       Date:  2016-06-29

4.  Arthroscopic autologous chondrocyte implantation in the hip for the treatment of full-thickness cartilage defects - A case series of 29 patients and review of the literature.

Authors:  Steffen Thier; Christel Weiss; Stefan Fickert
Journal:  SICOT J       Date:  2017-12-19

5.  Validity and Reliability of the Thai Version of the International Hip Outcome Tool in Young to Middle-Aged Physically Active Adults With Hip Disorders.

Authors:  Pisit Lertwanich; Siwa Loog-In; Chaturong Pornrattanamaneewong; Phob Ganokroj
Journal:  Orthop J Sports Med       Date:  2021-09-28

6.  Which anatomical conditions are associated with limitations of the hip function after SCFE?

Authors:  Nils Wirries; Gesche Heinrich; Alexander Derksen; Michael Schwarze; Stefan Budde; Henning Windhagen; Thilo Floerkemeier
Journal:  J Orthop       Date:  2021-07-12

7.  Validation of a German version of the International Hip Outcome Tool 12 (iHOT12) according to the COSMIN checklist.

Authors:  Florian Baumann; Daniel Popp; Karolina Müller; Michael Müller; Paul Schmitz; Michael Nerlich; Stefan Fickert
Journal:  Health Qual Life Outcomes       Date:  2016-01-08       Impact factor: 3.186

8.  Parameters affecting baseline hip function in patients with cam-derived femoroacetabular impingement syndrome: data analysis from the German Cartilage Registry.

Authors:  Sebastian Serong; Moritz Schutzbach; Stefan Fickert; Philipp Niemeyer; Christian Sobau; Gunther Spahn; Wolfgang Zinser; Stefan Landgraeber
Journal:  J Orthop Traumatol       Date:  2021-08-04

9.  Outcome-Affecting Parameters of Hip Arthroscopy for Femoroacetabular Impingement with Concomitant Cartilage Damage-Data Analysis from the German Cartilage Registry.

Authors:  Sebastian Serong; Stefan Fickert; Philipp Niemeyer; Ingo J Banke; Jens Goronzy; Christian Sobau; Wolfgang Zinser; Stefan Landgraeber
Journal:  J Clin Med       Date:  2022-03-10       Impact factor: 4.241

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.