Literature DB >> 26403632

Plate mouse.

Hitesh Lal1, Deepak Kumar Sharma2, Deepak Mittal3.   

Abstract

Fracture shaft humerus when surgically fixed is known to go into non-union and one of the main reasons of this is implant failure. The causes of implant failure may lie in the fracture personality, faulty implant material or choice, dubious surgical technique & faulty mechanics of fixation. Implants may break and cut-through but a unique type of implant migration from one surgical compartment to the other or one anatomical part of body to the other has not been hitherto reported. A 45-year-old male, farmer by occupation, was operated for fracture shaft of humerus 15 years back. He presented to us because of pain due to subcutaneous presence of plate in forearm. X-ray of the elbow with forearm showed that the plate used for fixation of humerus had migrated from one body part to another that is from arm to forearm. The patient on deliberation regarding the pros and cons of surgical treatment options, chose not to get his humerus non-union resolved surgically. This was because he could do his activities related to farming reasonably well.

Entities:  

Keywords:  Humerus; Implant failure; Non-union fracture; Plate migration

Year:  2012        PMID: 26403632      PMCID: PMC3880503          DOI: 10.1016/j.jcot.2012.09.005

Source DB:  PubMed          Journal:  J Clin Orthop Trauma        ISSN: 0976-5662


  6 in total

1.  Open reduction and internal fixation of humeral nonunions : a biomechanical and clinical study.

Authors:  Iván F Rubel; Peter Kloen; Deirdre Campbell; Mark Schwartz; Alan Liew; Elizabeth Myers; David L Helfet
Journal:  J Bone Joint Surg Am       Date:  2002-08       Impact factor: 5.284

2.  Kirschner wire migration from the pelvis to the heart and a new method of fixation of articular fracture fragments, acetabular reconstruction.

Authors:  B R McCardel; L E Dahners; J B Renner
Journal:  J Orthop Trauma       Date:  1989       Impact factor: 2.512

3.  Acute median nerve injury due to migration of a Kirschner wire.

Authors:  I M Jou; K A Lai
Journal:  J Hand Surg Br       Date:  1998-02

4.  Humeral shaft nonunion: evaluation of uniform surgical repair in fifty-one patients.

Authors:  R K Marti; C C P M Verheyen; P P Besselaar
Journal:  J Orthop Trauma       Date:  2002-02       Impact factor: 2.512

5.  Salvage of humeral nonunions with onlay bone plate allograft augmentation.

Authors:  F J Hornicek; G A Zych; J J Hutson; T I Malinin
Journal:  Clin Orthop Relat Res       Date:  2001-05       Impact factor: 4.176

6.  Medial migration of lag screw with intrapelvic dislocation in gamma nailing--a unique problem? A report of 2 cases.

Authors:  Martin Lucke; Rolf D Burghardt; Sebastian Siebenlist; Andreas Ganslmeier; Ulrich Stöckle
Journal:  J Orthop Trauma       Date:  2010-02       Impact factor: 2.512

  6 in total
  1 in total

1.  SF-36 physical function and general health domains are independent predictors of acute hospital length of stay after hip fracture surgery.

Authors:  Craigven H S Sim; Rehena Sultana; Kenny X K Tay; C Y Howe; T S Howe; Joyce S B Koh
Journal:  Musculoskelet Surg       Date:  2022-07-07
  1 in total