Literature DB >> 11347837

Salvage of humeral nonunions with onlay bone plate allograft augmentation.

F J Hornicek1, G A Zych, J J Hutson, T I Malinin.   

Abstract

Eight women and one man were treated for 10 established diaphyseal humeral nonunions. Six patients sustained fractures in motor vehicle accidents and two patients sustained fractures in a fall. Two of the fractures were open. One patient with multiple myeloma originally was treated conservatively and received local radiation, followed by open reduction and internal plate fixation. The other patients previously were treated with fracture braces, intramedullary nails, dynamic compression plates, or a combination of these techniques. After removal of the surgical hardware and fibrous tissue at the nonunion site, stable fixation was accomplished using a cortical long bone plate allograft (femoral and tibial) or fibular shaft allograft and a dynamic compression plate. All humeral nonunions had united at an average of 2.9 months. Radiographic incorporation of the allograft cortical bone plate and fibular shaft into the host cortex occurred in all but one patient by 3 months. Graft to host junction healing was accomplished by incorporation of the cortical allograft plate into the host cortex, resulting in an increased diameter of the bone. Cortical allograft bone plates and fibular grafts provide structural and probably osteoinductive support to enhance healing of these nonunions.

Entities:  

Mesh:

Year:  2001        PMID: 11347837     DOI: 10.1097/00003086-200105000-00026

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  22 in total

1.  Is tissue augmentation a reality in biosurgery? An experimental study of endothelial cell invasion into tissue filler.

Authors:  Tomaz Velnar; Vladimir Smrkolj; Marjan Slak Rupnik; Lidija Gradisnik
Journal:  Int Wound J       Date:  2012-04-09       Impact factor: 3.315

2.  Shape memory Ni-Ti alloy swan-like bone connector for treatment of humeral shaft nonunion.

Authors:  Jia-Can Su; Xin-Wei Liu; Bao-Qing Yu; Zhuo-Dong Li; Ming Li; Chun-Cai Zhang
Journal:  Int Orthop       Date:  2009-02-07       Impact factor: 3.075

3.  Humeral shaft aseptic nonunion: treatment with opposite cortical allograft struts.

Authors:  Alessandro Marinelli; Diego Antonioli; Enrico Guerra; Graziano Bettelli; Lorenzo Zaccarelli; Roberto Rotini
Journal:  Chir Organi Mov       Date:  2009-04

4.  Value of ultrasonography for observation of early healing of humeral shaft fractures.

Authors:  Hai-Qing Su; Xiao-Qiang Zhuang; Yu Bai; Hai-Hong Ye; Xiao-Hua Huang; Bing-Bing Lu; Sheng-Lin Lu; De-Yi Nong; Wei Wang
Journal:  J Med Ultrason (2001)       Date:  2013-03-15       Impact factor: 1.314

5.  A case series and review of salvage surgery for refractory humeral shaft nonunion following two or more prior surgical procedures.

Authors:  Todd A Borus; Edward H Yian; Madhav A Karunakar
Journal:  Iowa Orthop J       Date:  2005

6.  Results of non-union of humerus treated with retrograde humeral nail.

Authors:  Hinesh Bhatt; Bobin Varghese; Hannah Phillips; Rohit Rambani; Subhash Halder
Journal:  Eur J Orthop Surg Traumatol       Date:  2014-11-27

7.  "Sandwich technique" in the surgical treatment of primary complex fractures of the femur and humerus.

Authors:  A Gogus; C Ozturk; M Tezer; K Camurdan; A Hamzaoglu
Journal:  Int Orthop       Date:  2006-05-12       Impact factor: 3.075

8.  Locked intramedullary nailing for difficult nonunions of the humeral diaphysis.

Authors:  I Ilyas; D A Younge
Journal:  Int Orthop       Date:  2003-05-22       Impact factor: 3.075

9.  Plate mouse.

Authors:  Hitesh Lal; Deepak Kumar Sharma; Deepak Mittal
Journal:  J Clin Orthop Trauma       Date:  2012-09-21

10.  The use of a new locking 90 degree blade plate in the treatment of atrophic proximal humerus nonunions.

Authors:  Christian Allende; Bartolome T Allende
Journal:  Int Orthop       Date:  2008-10-31       Impact factor: 3.075

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.