Literature DB >> 12744395

A comparison of the performance of time-delay estimators in medical ultrasound.

Francesco Viola1, William F Walker.   

Abstract

Time-delay estimation (TDE) is a common operation in ultrasound signal processing. In applications such as blood flow estimation, elastography, phase aberration correction, and many more, the quality of final results is heavily dependent upon the performance of the time-delay estimator implemented. In the past years, several algorithms have been developed and applied in medical ultrasound, sonar, radar, and other fields. In this paper we analyze the performances of the widely used normalized and non-normalized correlations, along with normalized covariance, sum absolute differences (SAD), sum squared differences (SSD), hybrid-sign correlation, polarity-coincidence correlation, and the Meyr-Spies method. These techniques have been applied to simulated ultrasound radio frequency (RF) data under a variety of conditions. We show how parameters, which include center frequency, fractional bandwidth, kernel window size, signal decorrelation, and signal-to-noise ratio (SNR) affect the quality of the delay estimate. Simulation results also are compared with a theoretical performance limit set by the Cramér-Rao lower bound (CRLB). Results show that, for high SNR, high signal correlation, and large kernel size, all of the algorithms closely match the theoretical bound, with relative performances that vary by as much as 20%. As conditions degrade, the performances of various algorithms differ more significantly. For signals with a correlation level of 0.98, SNR of 30 dB, center frequency of 5 MHz with a fractional bandwidth of 0.5, and kernel size of 2 micros, the standard deviation of the jitter error is on the order of few nanoseconds. Normalized correlation, normalized covariance, and SSD have an approximately equal jitter error of 2.23 ns (the value predicted by the CRLB is 2.073 ns), whereas the polarity-coincidence correlation performs less well with a jitter error of 2.74 ns.

Entities:  

Mesh:

Year:  2003        PMID: 12744395     DOI: 10.1109/tuffc.2003.1197962

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  31 in total

1.  Volumetric elasticity imaging with a 2-D CMUT array.

Authors:  Ted G Fisher; Timothy J Hall; Satchi Panda; Michael S Richards; Paul E Barbone; Jingfeng Jiang; Jeff Resnick; Steve Barnes
Journal:  Ultrasound Med Biol       Date:  2010-06       Impact factor: 2.998

2.  Ultrasound echoes as biometric navigators.

Authors:  Benjamin M Schwartz; Nathan J McDannold
Journal:  Magn Reson Med       Date:  2012-05-30       Impact factor: 4.668

3.  Ultrasonic tracking of acoustic radiation force-induced displacements in homogeneous media.

Authors:  Mark L Palmeri; Stephen A McAleavey; Gregg E Trahey; Kathryn R Nightingale
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2006-07       Impact factor: 2.725

4.  Computationally efficient spline-based time delay estimation.

Authors:  Francesco Viola; William F Walker
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2008-09       Impact factor: 2.725

5.  Two-dimensional simulations of displacement accumulation incorporating shear strain.

Authors:  Matthew Bayer; Timothy J Hall; Lucio P Neves; A A O Carneiro
Journal:  Ultrason Imaging       Date:  2014-01       Impact factor: 1.578

6.  MUlti-Dimensional Spline-Based Estimator (MUSE) for motion estimation: algorithm development and initial results.

Authors:  Francesco Viola; Ryan L Coe; Kevin Owen; Drake A Guenther; William F Walker
Journal:  Ann Biomed Eng       Date:  2008-09-20       Impact factor: 3.934

7.  Nondestructive measurement of esophageal biaxial mechanical properties utilizing sonometry.

Authors:  Johnathon M Aho; Bo Qiang; Dennis A Wigle; Daniel J Tschumperlin; Matthew W Urban
Journal:  Phys Med Biol       Date:  2016-06-08       Impact factor: 3.609

8.  Ultrasound 2D Strain Estimator Based on Image Registration for Ultrasound Elastography.

Authors:  Xiaofeng Yang; Mylin Torres; Stephanie Kirkpatrick; Walter J Curran; Tian Liu
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2014-03-20

9.  Variance and covariance of accumulated displacement estimates.

Authors:  Matthew Bayer; Timothy J Hall
Journal:  Ultrason Imaging       Date:  2013-04       Impact factor: 1.578

10.  Harmonic motion detection in a vibrating scattering medium.

Authors:  Matthew W Urban; Shigao Chen; James Greenleaf
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2008-09       Impact factor: 2.725

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.