Literature DB >> 2639957

An in vitro comparison of five root canal length measuring instruments.

A F Fouad, K V Krell.   

Abstract

Several new root canal length measuring instruments (RCLMI) have recently been introduced claiming superiority over older systems. The purpose of this study was to compare five models of these instruments with respect to their accuracy under a given set of specified conditions. The five RCLMI tested were: the, Exact-a-pex, the Endocater, the Neosono-D, the Apex Finder, and the Sono-Explorer, Mark III. The conditions tested were the accuracy of the instruments in determining the working length, the consistency of measurement following canal instrumentation and with conductive gutta-percha points in place, and the operation of the RCLMI in the presence of fluids frequently found in root canals during endodontic treatment. An in vitro model was used to test these instruments. A set of 20 teeth was tested using the conditions specified above. All data were compared using the mean difference from the actual canal length of the teeth. The results indicated that there were no significant differences among measurements derived from the five instruments, under the specified conditions. There was a slight variation of the measurements by all instruments when they were used following instrumentation and with the use of conductive gutta-percha points. When fluids were present in the canals, the reliability of the RCLMI depended on the electrical conductivity of the fluid tested. The poorest results were obtained when either sodium hypochlorite or blood were present in the canals.

Entities:  

Mesh:

Substances:

Year:  1989        PMID: 2639957     DOI: 10.1016/S0099-2399(89)80152-9

Source DB:  PubMed          Journal:  J Endod        ISSN: 0099-2399            Impact factor:   4.171


  3 in total

1.  Accuracy of an Electronic Apex Locator for Working Length Determination in Primary Anterior Teeth.

Authors:  Zahra Bahrololoomi; Ali Asghar Soleymani; Jalil Modaresi; Mahsa Imanian; Malihe Lotfian
Journal:  J Dent (Tehran)       Date:  2015-04

2.  A comparative assessment of the accuracy of electronic apex locator (Root ZX) in the presence of commonly used irrigating solutions.

Authors:  Osama Khattak; Ebadullah Raidullah; Maria L Francis
Journal:  J Clin Exp Dent       Date:  2014-02-01

3.  Comparison of Accuracy in Determining the Root Canal Working Length by Using Two Generations of Apex Locators - An In Vitro Study.

Authors:  Kapil Golvankar; Mohammed Abdul Kader; Abhilash Abdul Latheef; Ahamed Babiker Mohammed Ali; Shahabe Saquib Abullais; Mohammed Sibagathullah
Journal:  Open Access Maced J Med Sci       Date:  2019-09-11
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.