Literature DB >> 26396233

Point-of-care testing of electrolytes and calcium using blood gas analysers: it is time we trusted the results.

Mehdi Mirzazadeh1, Alireza Morovat1, Tim James1, Ian Smith1, Justin Kirby1, Brian Shine1.   

Abstract

BACKGROUND: Point-of-care testing allows rapid analysis of samples to facilitate prompt clinical decisions. Electrolyte and calcium abnormalities are common in acutely ill patients and can be associated with life-threatening consequences. There is uncertainty whether clinical decisions can be based on the results obtained from blood gas analysers or if laboratory results should be awaited.
OBJECTIVES: To assess the agreement between sodium, potassium and calcium results from blood gas and laboratory mainstream analysers in a tertiary centre, with a network consisting of one referral and two peripheral hospitals, consisting of three networked clinical biochemistry laboratories.
METHOD: Using the laboratory information management system database and over 11 000 paired samples in three hospital sites, the results of sodium, potassium and ionised calcium on blood gas analysers were studied over a 5-year period and compared with the corresponding laboratory results from the same patients booked in the laboratory within 1 h.
RESULTS: The Pearson's linear correlation coefficient between laboratory and blood gas results for sodium, potassium and calcium were 0.92, 0.84 and 0.78, respectively. Deming regression analysis showed a slope of 1.04 and an intercept of -5.7 for sodium, slope of 0.93 and an intercept of 0.22 for potassium and a slope of 1.23 with an intercept of -0.55 for calcium. With some strict statistical assumptions, percentages of results lying outside the least significant difference were 9%, 26.7% and 20.8% for sodium, potassium and calcium, respectively.
CONCLUSIONS: Most clinicians wait for the laboratory confirmation of results generated by blood gas analysers. In a large retrospective study we have shown that there is sufficient agreement between the results obtained from the blood gas and laboratory analysers to enable prompt clinical decisions to be made. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

Entities:  

Keywords:  clinical management; diagnosis; errors; interpretation; metabolic/diabetes/endocrine

Mesh:

Substances:

Year:  2015        PMID: 26396233     DOI: 10.1136/emermed-2015-204669

Source DB:  PubMed          Journal:  Emerg Med J        ISSN: 1472-0205            Impact factor:   2.740


  6 in total

1.  Sodium supply influences plasma sodium concentration and the risks of hyper- and hyponatremia in extremely preterm infants.

Authors:  Cornelia Späth; Elisabeth Stoltz Sjöström; Fredrik Ahlsson; Johan Ågren; Magnus Domellöf
Journal:  Pediatr Res       Date:  2016-12-09       Impact factor: 3.756

2.  Point of Care Testing of Serum Electrolytes and Lactate in Sick Children.

Authors:  Aashima Dabas; Shipra Agrawal; Vernika Tyagi; Shikha Sharma; Vandana Rastogi; Urmila Jhamb; Pradeep Kumar Dabla
Journal:  EJIFCC       Date:  2021-06-29

3.  Things We Do for No Reason™: Calculating a "Corrected Calcium" Level.

Authors:  Colin M Kenny; Caroline E Murphy; Dacia S Boyce; Deptmer M Ashley; Jay Jahanmir
Journal:  J Hosp Med       Date:  2021-08       Impact factor: 2.899

4.  Detection and Quantification of Tightly Bound Zn2+ in Blood Serum Using a Photocaged Chelator and a DNAzyme Fluorescent Sensor.

Authors:  Shige Xing; Yao Lin; Liangyuan Cai; Prem N Basa; Austin K Shigemoto; Chengbin Zheng; Feng Zhang; Shawn C Burdette; Yi Lu
Journal:  Anal Chem       Date:  2021-03-31       Impact factor: 8.008

5.  Point-of-Care Versus Central Laboratory Measurements of Hemoglobin, Hematocrit, Glucose, Bicarbonate and Electrolytes: A Prospective Observational Study in Critically Ill Patients.

Authors:  Jérôme Allardet-Servent; Melissa Lebsir; Christian Dubroca; Martine Fabrigoule; Sylvie Jordana; Thomas Signouret; Matthias Castanier; Guillemette Thomas; Rettinavelou Soundaravelou; Anne Lepidi; Laurence Delapierre; Guillaume Penaranda; Philippe Halfon; Jean-Marie Seghboyan
Journal:  PLoS One       Date:  2017-01-10       Impact factor: 3.240

6.  Performance evaluation of the i-Smart 300E cartridge for point-of-care electrolyte measurement in serum and plasma.

Authors:  Beomki Lee; Hyung-Doo Park
Journal:  J Clin Lab Anal       Date:  2022-02-14       Impact factor: 2.352

  6 in total