Literature DB >> 26394340

Time-Efficiency Analysis Comparing Digital and Conventional Workflows for Implant Crowns: A Prospective Clinical Crossover Trial.

Tim Joda, Urs Brägger.   

Abstract

PURPOSE: To compare time-efficiency in the production of implant crowns using a digital workflow versus the conventional pathway.
MATERIALS AND METHODS: This prospective clinical study used a crossover design that included 20 study participants receiving single-tooth replacements in posterior sites. Each patient received a customized titanium abutment plus a computer-aided design/computer-assisted manufacture (CAD/CAM) zirconia suprastructure (for those in the test group, using digital workflow) and a standardized titanium abutment plus a porcelain-fused-to-metal crown (for those in the control group, using a conventional pathway). The start of the implant prosthetic treatment was established as the baseline. Time-efficiency analysis was defined as the primary outcome, and was measured for every single clinical and laboratory work step in minutes. Statistical analysis was calculated with the Wilcoxon rank sum test.
RESULTS: All crowns could be provided within two clinical appointments, independent of the manufacturing process. The mean total production time, as the sum of clinical plus laboratory work steps, was significantly different. The mean ± standard deviation (SD) time was 185.4 ± 17.9 minutes for the digital workflow process and 223.0 ± 26.2 minutes for the conventional pathway (P = .0001). Therefore, digital processing for overall treatment was 16% faster. Detailed analysis for the clinical treatment revealed a significantly reduced mean ± SD chair time of 27.3 ± 3.4 minutes for the test group compared with 33.2 ± 4.9 minutes for the control group (P = .0001). Similar results were found for the mean laboratory work time, with a significant decrease of 158.1 ± 17.2 minutes for the test group vs 189.8 ± 25.3 minutes for the control group (P = .0001).
CONCLUSION: Only a few studies have investigated efficiency parameters of digital workflows compared with conventional pathways in implant dental medicine. This investigation shows that the digital workflow seems to be more time-efficient than the established conventional production pathway for fixed implant-supported crowns. Both clinical chair time and laboratory manufacturing steps could be effectively shortened with the digital process of intraoral scanning plus CAD/CAM technology.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 26394340     DOI: 10.11607/jomi.3963

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  19 in total

Review 1.  Production time, effectiveness and costs of additive and subtractive computer-aided manufacturing (CAM) of implant prostheses: A systematic review.

Authors:  Sven Mühlemann; Jenni Hjerppe; Christoph H F Hämmerle; Daniel S Thoma
Journal:  Clin Oral Implants Res       Date:  2021-10       Impact factor: 5.021

Review 2.  The complete digital workflow in fixed prosthodontics: a systematic review.

Authors:  Tim Joda; Fernando Zarone; Marco Ferrari
Journal:  BMC Oral Health       Date:  2017-09-19       Impact factor: 2.757

Review 3.  Intraoral scanners in dentistry: a review of the current literature.

Authors:  Francesco Mangano; Andrea Gandolfi; Giuseppe Luongo; Silvia Logozzo
Journal:  BMC Oral Health       Date:  2017-12-12       Impact factor: 2.757

4.  Conventional Vs Digital Impressions: Acceptability, Treatment Comfort and Stress Among Young Orthodontic Patients.

Authors:  Alessandro Mangano; Matteo Beretta; Giuseppe Luongo; Carlo Mangano; Francesco Mangano
Journal:  Open Dent J       Date:  2018-01-31

5.  Accuracy of four intraoral scanners in oral implantology: a comparative in vitro study.

Authors:  Mario Imburgia; Silvia Logozzo; Uli Hauschild; Giovanni Veronesi; Carlo Mangano; Francesco Guido Mangano
Journal:  BMC Oral Health       Date:  2017-06-02       Impact factor: 2.757

6.  Digital versus Analog Procedures for the Prosthetic Restoration of Single Implants: A Randomized Controlled Trial with 1 Year of Follow-Up.

Authors:  Francesco Mangano; Giovanni Veronesi
Journal:  Biomed Res Int       Date:  2018-07-18       Impact factor: 3.411

7.  Impact of Aging on the Accuracy of 3D-Printed Dental Models: An In Vitro Investigation.

Authors:  Tim Joda; Lea Matthisson; Nicola U Zitzmann
Journal:  J Clin Med       Date:  2020-05-12       Impact factor: 4.241

8.  Accuracy of Implant Casts Generated with Conventional and Digital Impressions-An In Vitro Study.

Authors:  Paulo Ribeiro; Mariano Herrero-Climent; Carmen Díaz-Castro; José Vicente Ríos-Santos; Roberto Padrós; Javier Gil Mur; Carlos Falcão
Journal:  Int J Environ Res Public Health       Date:  2018-07-27       Impact factor: 3.390

Review 9.  The direct digital workflow in fixed implant prosthodontics: a narrative review.

Authors:  George Michelinakis; Dimitrios Apostolakis; Phophi Kamposiora; George Papavasiliou; Mutlu Özcan
Journal:  BMC Oral Health       Date:  2021-01-21       Impact factor: 2.757

10.  The Prosthetic Workflow in the Digital Era.

Authors:  Lidia Tordiglione; Michele De Franco; Giovanni Bosetti
Journal:  Int J Dent       Date:  2016-10-18
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.