Literature DB >> 26390142

Automated 3D quantitative assessment and measurement of alpha angles from the femoral head-neck junction using MR imaging.

Ying Xia, Jurgen Fripp, Shekhar S Chandra, Duncan Walker, Stuart Crozier, Craig Engstrom.   

Abstract

To develop an automated approach for 3D quantitative assessment and measurement of alpha angles from the femoral head-neck (FHN) junction using bone models derived from magnetic resonance (MR) images of the hip joint.Bilateral MR images of the hip joints were acquired from 30 male volunteers (healthy active individuals and high-performance athletes, aged 18–49 years) using a water-excited 3D dual echo steady state (DESS) sequence. In a subset of these subjects (18 water-polo players), additional True Fast Imaging with Steady-state Precession (TrueFISP) images were acquired from the right hip joint. For both MR image sets, an active shape model based algorithm was used to generate automated 3D bone reconstructions of the proximal femur. Subsequently, a local coordinate system of the femur was constructed to compute a 2D shape map to project femoral head sphericity for calculation of alpha angles around the FHN junction. To evaluate automated alpha angle measures, manual analyses were performed on anterosuperior and anterior radial MR slices from the FHN junction that were automatically reformatted using the constructed coordinate system.High intra- and inter-rater reliability (intra-class correlation coefficients  >  0.95) was found for manual alpha angle measurements from the auto-extracted anterosuperior and anterior radial slices. Strong correlations were observed between manual and automatic measures of alpha angles for anterosuperior (r  =  0.84) and anterior (r  =  0.92) FHN positions. For matched DESS and TrueFISP images, there were no significant differences between automated alpha angle measures obtained from the upper anterior quadrant of the FHN junction (two-way repeated measures ANOVA, F  <  0.01, p  =  0.98).Our automatic 3D method analysed MR images of the hip joints to generate alpha angle measures around the FHN junction circumference with very good reliability and reproducibility. This work has the potential to improve analyses of cam-type lesions of the FHN junction for large-scale morphometric and clinical MR investigations of the human hip region.

Entities:  

Mesh:

Year:  2015        PMID: 26390142     DOI: 10.1088/0031-9155/60/19/7601

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  7 in total

1.  Automated Morphometric Analysis of the Hip Joint on MRI from the German National Cohort Study.

Authors:  Marc Fischer; Sven S Walter; Tobias Hepp; Manuela Zimmer; Mike Notohamiprodjo; Fritz Schick; Bin Yang
Journal:  Radiol Artif Intell       Date:  2021-06-02

2.  Cam deformity and the omega angle, a novel quantitative measurement of femoral head-neck morphology: a 3D CT gender analysis in asymptomatic subjects.

Authors:  Vasco V Mascarenhas; Paulo Rego; Pedro Dantas; Augusto Gaspar; Francisco Soldado; José G Consciência
Journal:  Eur Radiol       Date:  2016-08-30       Impact factor: 5.315

3.  MR arthrography of the hip: diagnostic performance and image quality of 3D-steady state free precession versus 2D turbo spin echo sequences.

Authors:  Mareen Sarah Kraus; Mike Notohamiprodjo; Sasan Partovi; Ahmed Sobieh; Andrea Baur-Melnyk; Joerg Hausdorf; Ulrich Grosse
Journal:  Skeletal Radiol       Date:  2018-01-12       Impact factor: 2.199

4.  Does 3DMR provide equivalent information as 3DCT for the pre-operative evaluation of adult Hip pain conditions of femoroacetabular impingement and Hip dysplasia?

Authors:  Kevin Yan; Yin Xi; Chayanit Sasiponganan; Joseph Zerr; Joel E Wells; Avneesh Chhabra
Journal:  Br J Radiol       Date:  2018-08-07       Impact factor: 3.039

5.  Automated measurement of alpha angle on 3D-magnetic resonance imaging in femoroacetabular impingement hips: a pilot study.

Authors:  Nastassja Pamela Ewertowski; Christoph Schleich; Daniel Benjamin Abrar; Harish S Hosalkar; Bernd Bittersohl
Journal:  J Orthop Surg Res       Date:  2022-07-30       Impact factor: 2.677

6.  Automated 3D Analysis of Clinical Magnetic Resonance Images Demonstrates Significant Reductions in Cam Morphology Following Arthroscopic Intervention in Contrast to Physiotherapy.

Authors:  Jessica M Bugeja; Ying Xia; Shekhar S Chandra; Nicholas J Murphy; Jillian Eyles; Libby Spiers; Stuart Crozier; David J Hunter; Jurgen Fripp; Craig Engstrom
Journal:  Arthrosc Sports Med Rehabil       Date:  2022-06-08

Review 7.  Imaging of femoroacetabular impingement-current concepts.

Authors:  Christoph E Albers; Nicholas Wambeek; Markus S Hanke; Florian Schmaranzer; Gareth H Prosser; Piers J Yates
Journal:  J Hip Preserv Surg       Date:  2016-11-10
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.