Literature DB >> 26386839

Intrarater reliability of goniometry and hand-held dynamometry for shoulder and elbow examinations in female team handball athletes and asymptomatic volunteers.

Georg Fieseler1, Thomas Molitor2, Lars Irlenbusch2, Karl-Stefan Delank2, Kevin G Laudner3, Souhail Hermassi4, Rene Schwesig2.   

Abstract

INTRODUCTION: To evaluate the intrarater reliability for examining active range of motion (ROM) and isometric strength of the shoulder and elbow among asymptomatic female team handball athletes and a control group using a manual goniometer and hand-held dynamometry (HHD).
MATERIALS AND METHODS: 22 female team handball athletes (age: 21.0 ± 3.7 years) and 25 volunteers (13 female, 12 male, age: 21.9 ± 1.24 years) participated to determine bilateral ROM for shoulder rotation and elbow flexion/extension, as well as isometric shoulder rotation and elbow flexion/extension strength. Subjects were assessed on two separate test sessions with 7 days between sessions. Relative (intraclass correlation coefficients (ICC) and standard error of measurement (SEM) reliability were calculated.
RESULTS: Reliability for ROM and strength were good to excellent for both shoulders and groups (athletes: ICC = 0.94-0.97, SEM 1.07°-4.76 N, controls: ICC = 0.96-1.00, SEM = 0.00 N-4.48 N). Elbow measurements for both groups also showed good-to-excellent reliability (athletes: ICC = 0.79-0.97, SEM = 0.98°-5.94 N, controls: ICC = 0.87-1.00, SEM = 0.00 N-5.43 N).
CONCLUSIONS: It is important to be able to reliably reproduce active ROM and isometric strength evaluations. Using a standardized testing position, goniometry and HHD are reliable instruments in the assessment of shoulder and elbow joint performance testing. We showed good-to-excellent reproducible results for male and female control subjects and female handball athletes, although the single parameters in ROM and strength were different for each group and between the shoulders and elbows.

Entities:  

Keywords:  Elbow; Goniometry; Hand-held dynamometry; Range of motion; Reliability; Shoulder; Strength

Mesh:

Year:  2015        PMID: 26386839     DOI: 10.1007/s00402-015-2331-6

Source DB:  PubMed          Journal:  Arch Orthop Trauma Surg        ISSN: 0936-8051            Impact factor:   3.067


  12 in total

1.  The Self-Assessment Corner for Shoulder Strength: Reliability, Validity, and Correlations With Upper Extremity Physical Performance Tests.

Authors:  Philippe Decleve; Joachim Van Cant; Ellen De Buck; Justine Van Doren; Julie Verkouille; Ann M Cools
Journal:  J Athl Train       Date:  2020-02-13       Impact factor: 2.860

2.  Normalized Isometric Shoulder Strength as a Predictor of Ball Velocity in Youth Baseball Players.

Authors:  Amanda J Arnold; Charles A Thigpen; Paul F Beattie; Stacy L Fritz; Michael J Kissenberth; John M Tokish; Ellen Shanley
Journal:  Int J Sports Phys Ther       Date:  2022-02-01

3.  Isometric strength of upper limb muscles in youth using hand-held and hand-grip dynamometry.

Authors:  Guillermo Mendez-Rebolledo; Arturo Ruiz-Gutierrez; Sebastian Salas-Villar; Eduardo Guzman-Muñoz; Sergio Sazo-Rodriguez; Eric Urbina-Santibáñez
Journal:  J Exerc Rehabil       Date:  2022-06-27

4.  Normative values and affecting factors for the elbow range of motion.

Authors:  Elisa L Zwerus; Nienke W Willigenburg; Vanessa A Scholtes; Matthijs P Somford; Denise Eygendaal; Michel Pj van den Bekerom
Journal:  Shoulder Elbow       Date:  2017-09-11

5.  CLINICAL REASONING IN THE FACE OF UNCERTAINTY: CONSERVATIVE PHYSICAL THERAPY MANAGEMENT OF A TEENAGE ATHLETE DIAGNOSED WITH A PROXIMAL HUMERAL NON-OSSIFYING FIBROMA.

Authors:  Timothy J Reynolds; Joseph Paul Coviello; Michael Costello
Journal:  Int J Sports Phys Ther       Date:  2018-12

Review 6.  The reliability and validity of goniometric elbow measurements in adults: A systematic review of the literature.

Authors:  Suzanne F van Rijn; Elisa L Zwerus; Koen Lm Koenraadt; Wilco Ch Jacobs; Michel Pj van den Bekerom; Denise Eygendaal
Journal:  Shoulder Elbow       Date:  2018-06-03

7.  Inter- and intrarater reliability of goniometry and hand held dynamometry for patients with subacromial impingement syndrome.

Authors:  Georg Fieseler; Kevin G Laudner; Lars Irlenbusch; Henrike Meyer; Stephan Schulze; Karl-Stefan Delank; Souhail Hermassi; Thomas Bartels; René Schwesig
Journal:  J Exerc Rehabil       Date:  2017-12-27

8.  Validity and Reliability of Elbow Range of Motion Measurements Using Digital Photographs, Movies, and a Goniometry Smartphone Application.

Authors:  Renée Keijsers; Elisa L Zwerus; Dagmar R M van Lith; Koen L M Koenraadt; Pjotr Goossens; Bertram The; Michel P J van den Bekerom; Denise Eygendaal
Journal:  J Sports Med (Hindawi Publ Corp)       Date:  2018-11-29

9.  Accuracy and reliability of tridimensional electromagnetic sensor system for elbow ROM measurement.

Authors:  Kohei Yamaura; Yutaka Mifune; Atsuyuki Inui; Hanako Nishimoto; Takeshi Kataoka; Takashi Kurosawa; Shintaro Mukohara; Yuichi Hoshino; Takahiro Niikura; Kouki Nagamune; Ryosuke Kuroda
Journal:  J Orthop Surg Res       Date:  2022-01-29       Impact factor: 2.359

10.  Validity and reliability of the DiCI for the measurement of shoulder flexion and abduction strength in asymptomatic and symptomatic subjects.

Authors:  Javier González-Rosalén; Alba Cuerda-Del Pino; Mariana Sánchez-Barbadora; Rodrigo Martín-San Agustín
Journal:  PeerJ       Date:  2021-06-09       Impact factor: 2.984

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.