Literature DB >> 26384753

A comparison of conventional surgery, transcatheter aortic valve replacement, and sutureless valves in "real-world" patients with aortic stenosis and intermediate- to high-risk profile.

Claudio Muneretto1, Ottavio Alfieri2, Bruno Mario Cesana3, Gianluigi Bisleri4, Michele De Bonis2, Roberto Di Bartolomeo5, Carlo Savini5, Gianluca Folesani5, Lorenzo Di Bacco4, Manfredo Rambaldini6, Juan Pablo Maureira7, Francois Laborde8, Maurizio Tespili9, Alberto Repossini4, Thierry Folliguet7.   

Abstract

OBJECTIVE: We sought to investigate the clinical outcomes of patients with isolated severe aortic stenosis and an intermediate- to high-risk profile treated by means of conventional surgery (surgical aortic valve replacement), sutureless valve implantation, or transcatheter aortic valve replacement in a multicenter evaluation.
METHODS: Among 991 consecutive patients with isolated severe aortic stenosis and an intermediate- to high-risk profile (Society of Thoracic Surgeons score >4 and logistic European System for Cardiac Operative Risk Evaluation I >10), a propensity score analysis was performed on the basis of the therapeutic strategy: surgical aortic valve replacement (n = 204), sutureless valve implantation (n = 204), and transcatheter aortic valve replacement (n = 204). Primary end points were 30-day mortality and overall survival at 24-month follow-up; the secondary end point was survival free from a composite end point of major adverse cardiac events (defined as cardiac-related mortality, myocardial infarction, cerebrovascular accidents, and major hemorrhagic events) and periprosthetic regurgitation greater than 2.
RESULTS: Thirty-day mortality was significantly higher in the transcatheter aortic valve replacement group (surgical aortic valve replacement = 3.4% vs sutureless = 5.8% vs transcatheter aortic valve replacement = 9.8%; P = .005). The incidence of postprocedural was 3.9% in asurgical aortic valve replacement vs 9.8% in sutureless vs 14.7% in transcatheter aortic valve replacement (P< .001) and peripheral vascular complications occurred in 0% of surgicalaortic valve replacement vs 0% of sutureless vs 9.8% transcatheter aortic valve replacement (P< .001). At 24-month follow-up, overall survival (surgical aortic valve replacement = 91.3% ± 2.4% vs sutureless = 94.9% ± 2.1% vs transcatheter aortic valve replacement = 79.5% ± 4.3%; P < .001) and survival free from the composite end point of major adverse cardiovascular events and periprosthetic regurgitation were significantly better in patients undergoing surgical aortic valve replacement and sutureless valve implantation than in patients undergoing transcatheter aortic valve replacement (surgical aortic valve replacement = 92.6% ± 2.3% vs sutureless = 96% ± 1.8% vs transcatheter aortic valve replacement = 77.1% ± 4.2%; P < .001). Multivariate Cox regression analysis identified transcatheter aortic valve replacement as an independent risk factor for overall mortality hazard ratio (hazard ratio, 2.5; confidence interval, 1.1-4.2; P = .018).
CONCLUSIONS: The use of transcatheter aortic valve replacement in patients with an intermediate- to high-risk profile was associated with a significantly higher incidence of perioperative complications and decreased survival at short- and mid-term when compared with conventional surgery and sutureless valve implantation.
Copyright © 2015 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  aortic valve replacement; sutureless bioprosthesis; transcatheter valve implantation

Mesh:

Year:  2015        PMID: 26384753     DOI: 10.1016/j.jtcvs.2015.08.052

Source DB:  PubMed          Journal:  J Thorac Cardiovasc Surg        ISSN: 0022-5223            Impact factor:   5.209


  18 in total

Review 1.  Ten-year experience with the Perceval S sutureless prosthesis: lessons learned and future perspectives.

Authors:  Vincent Chauvette; Amine Mazine; Denis Bouchard
Journal:  J Vis Surg       Date:  2018-05-03

2.  Transcatheter aortic valve implantation (TAVI) versus sutureless aortic valve replacement (SUAVR) for aortic stenosis: a systematic review and meta-analysis of matched studies.

Authors:  Nelson Wang; Yi-Chin Tsai; Natasha Niles; Vakhtang Tchantchaleishvili; Marco Di Eusanio; Tristan D Yan; Kevin Phan
Journal:  J Thorac Dis       Date:  2016-11       Impact factor: 2.895

Review 3.  Cardiac surgery 2015 reviewed.

Authors:  Torsten Doenst; Constanze Strüning; Alexandros Moschovas; David Gonzalez-Lopez; Yasin Essa; Hristo Kirov; Mahmoud Diab; Gloria Faerber
Journal:  Clin Res Cardiol       Date:  2016-06-29       Impact factor: 5.460

4.  Simulated transcatheter aortic valve deformation: A parametric study on the impact of leaflet geometry on valve peak stress.

Authors:  Kewei Li; Wei Sun
Journal:  Int J Numer Method Biomed Eng       Date:  2016-07-26       Impact factor: 2.747

5.  Comparison of hemodynamic and clinical outcomes of transcatheter and sutureless aortic bioprostheses: how to make the right choice in intermediate risk patients.

Authors:  Augusto D'Onofrio; Assunta Fabozzo; Gino Gerosa
Journal:  Ann Cardiothorac Surg       Date:  2017-09

6.  Sutureless valves-are we there yet? Evidence from the PERSIST-AVR trial.

Authors:  Pradeep Narayan
Journal:  Indian J Thorac Cardiovasc Surg       Date:  2021-11-23

7.  Meta-Analysis Comparing the Frequency of Stroke After Transcatheter Versus Surgical Aortic Valve Replacement.

Authors:  Kuldeep Shah; Zakeih Chaker; Tatiana Busu; Vinay Badhwar; Fahad Alqahtani; Muhammad Alvi; Amelia Adcock; Mohamad Alkhouli
Journal:  Am J Cardiol       Date:  2018-07-05       Impact factor: 2.778

8.  Transcatheter, sutureless and conventional aortic-valve replacement: a network meta-analysis of 16,432 patients.

Authors:  Declan Lloyd; Jessica G Y Luc; Ben Elias Indja; Vannessa Leung; Nelson Wang; Kevin Phan
Journal:  J Thorac Dis       Date:  2019-01       Impact factor: 2.895

9.  Need for permanent pacemaker implantation following implantation of the rapid deployment valve in combined procedures: a single centre cohort study.

Authors:  Oliver Deutsch; Isabell Deisenhofer; Katharina Koch-Buettner; Rüdiger Lange; Markus Krane
Journal:  J Thorac Dis       Date:  2021-04       Impact factor: 2.895

10.  Quality of life, satisfaction and outcomes after ministernotomy versus full sternotomy isolated aortic valve replacement (QUALITY-AVR): study protocol for a randomised controlled trial.

Authors:  Emiliano A Rodríguez-Caulo; Ana Guijarro-Contreras; Juan Otero-Forero; María José Mataró; Gemma Sánchez-Espín; Arantza Guzón; Carlos Porras; Miguel Such; Antonio Ordóñez; José María Melero-Tejedor; Manuel Jiménez-Navarro
Journal:  Trials       Date:  2018-02-17       Impact factor: 2.279

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.