Full-arch implant fixed prostheses: a comparative study on the effect of connection type and impression technique on accuracy of fit.

Panos Papaspyridakos1,2, Hiroshi Hirayama1, Chun-Jung Chen3, Chung-Han Ho4, Vasilios Chronopoulos2,5, Hans-Peter Weber1.   

Abstract

PURPOSE: The aim of this study was to assess the effect of connection type and impression technique on the accuracy of fit of implant-supported fixed complete-arch dental prostheses (IFCDPs).
MATERIALS AND METHODS: An edentulous mandibular cast with five implants was fabricated to serve as master cast (control) for both implant- and abutment-level baselines. A titanium one-piece framework for an IFCDP was milled at abutment level and used for accuracy of fit measurements. Polyether impressions were made using a splinted and non-splinted technique at the implant and abutment level leading to four test groups, n = 10 each. Hence, four groups of test casts were generated. The impression accuracy was evaluated indirectly by assessing the fit of the IFCDP framework on the generated casts of the test groups, clinically and radiographically. Additionally, the control and all test casts were digitized with a high-resolution reference scanner (IScan D103i, Imetric, Courgenay, Switzerland) and standard tessellation language datasets were generated and superimposed. Potential correlations between the clinical accuracy of fit data and the data from the digital scanning were investigated. To compare the accuracy of casts of the test groups versus the control at the implant and abutment level, Fisher's exact test was used.
RESULTS: Of the 10 casts of test group I (implant-level splint), all 10 presented with accurate clinical fit when the framework was seated on its respective cast, while only five of 10 casts of test group II (implant-level non-splint) showed adequate fit. All casts of group III (abutment-level splint) presented with accurate fit, whereas nine of 10 of the casts of test group IV (abutment-level non-splint) were accurate. Significant 3D deviations (P < 0.05) were found between group II and the control. No statistically significant differences were found between groups I, III, and IV compared with the control. Implant connection type (implant level vs. abutment level) and impression technique did affect the 3D accuracy of implant impressions only with the non-splint technique (P < 0.05).
CONCLUSION: For one-piece IFCDPs, the implant-level splinted impression technique showed to be more accurate than the non-splinted approach, whereas at the abutment-level, no difference in the accuracy was found.
© 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

Entities:  

Keywords:  accuracy of fit; connection type; digital dentistry; edentulous; full-arch prostheses; implant impressions

Mesh:

Substances:

Year:  2015        PMID: 26374268     DOI: 10.1111/clr.12695

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  8 in total

1.  [Application evaluation of prefabricated rigid connecting bar in implants immediate impression preparation of edentulous jaw].

Authors:  J Wang; H J Yu; J D Sun; L X Qiu
Journal:  Beijing Da Xue Xue Bao Yi Xue Ban       Date:  2022-02-18

2.  Effect of Scanner Type and Scan Body Location on the Accuracy of Mandibular Complete-Arch Digital Implant Scans: An In Vitro Study.

Authors:  Gülce Çakmak; Hakan Yilmaz; Alejandro Treviño Santos; Ali Murat Kökat; Burak Yilmaz
Journal:  J Prosthodont       Date:  2021-09-21       Impact factor: 3.485

3.  Three-Dimensional Accuracy of Digital Impression versus Conventional Method: Effect of Implant Angulation and Connection Type.

Authors:  Marzieh Alikhasi; Hakime Siadat; Alireza Nasirpour; Mahya Hasanzade
Journal:  Int J Dent       Date:  2018-06-04

4.  In Vivo Complete-Arch Implant Digital Impressions: Comparison of the Precision of Three Optical Impression Systems.

Authors:  Jaime Orejas-Perez; Beatriz Gimenez-Gonzalez; Ignacio Ortiz-Collado; Israel J Thuissard; Andrea Santamaria-Laorden
Journal:  Int J Environ Res Public Health       Date:  2022-04-03       Impact factor: 3.390

5.  Influence of Implant Impression Methods, Polymer Materials, and Implant Angulation on the Accuracy of Dental Models.

Authors:  Daniela Djurovic Koprivica; Tatjana Puskar; Igor Budak; Mario Sokac; Milica Jeremic Knezevic; Aleksandra Maletin; Bojana Milekic; Djordje Vukelic
Journal:  Polymers (Basel)       Date:  2022-07-11       Impact factor: 4.967

6.  Restoring a post-traumatic partial edentulous mandible with the Toronto prosthesis: a clinical report.

Authors:  Fatemeh Nematollahi; Marzieh Alikhasi; Elaheh Beyabanaki
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2018-06-20

7.  Accuracy of new implant impression technique using dual arch tray and bite impression coping.

Authors:  Shin-Eon Lee; Sung-Eun Yang; Cheol-Won Lee; Won-Sup Lee; Su Young Lee
Journal:  J Adv Prosthodont       Date:  2018-08-17       Impact factor: 1.904

8.  A prospective clinical study on implant impression accuracy.

Authors:  Motaz Osman; Hassan Ziada; Ahmed Suliman; Neamat Hassan Abubakr
Journal:  Int J Implant Dent       Date:  2019-11-19
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.