Literature DB >> 26362452

An adaptive real-time beat detection method for continuous pressure signals.

Xiaochang Liu1, Gaofeng Wang2,3, Jia Liu4.   

Abstract

A novel adaptive real-time beat detection method for pressure related signals is proposed by virtue of an enhanced mean shift (EMS) algorithm. This EMS method consists of three components: spectral estimates of the heart rate, enhanced mean shift algorithm and classification logic. The Welch power spectral density method is employed to estimate the heart rate. An enhanced mean shift algorithm is then applied to improve the morphologic features of the blood pressure signals and detect the maxima of the blood pressure signals effectively. Finally, according to estimated heart rate, the classification logic is established to detect the locations of misdetections and over detections within the accepted heart rate limits. The parameters of the algorithm are adaptively tuned for ensuring its robustness in various heart rate conditions. The performance of the EMS method is validated with expert annotations of two standard databases and a non-invasive dataset. The results from this method show that the sensitivity (Se) and positive predictivity (+P) are significantly improved (i.e., Se > 99.45 %, +P > 98.28 %, and p value 0.0474) by comparison with the existing scheme from the previously published literature.

Keywords:  Arterial blood pressure (ABP); Beat detection; Intracranial pressure (ICP); Mean shift; Pulse oximetry (SpO2); Slope sum function

Mesh:

Substances:

Year:  2015        PMID: 26362452     DOI: 10.1007/s10877-015-9770-z

Source DB:  PubMed          Journal:  J Clin Monit Comput        ISSN: 1387-1307            Impact factor:   2.502


  17 in total

1.  A real-time algorithm for the quantification of blood pressure waveforms.

Authors:  Michael A Navakatikyan; Carolyn J Barrett; Geoffrey A Head; James H Ricketts; Simon C Malpas
Journal:  IEEE Trans Biomed Eng       Date:  2002-07       Impact factor: 4.538

2.  Microcontroller-based real-time QRS detection.

Authors:  Y Sun; S Suppappola; T A Wrublewski
Journal:  Biomed Instrum Technol       Date:  1992 Nov-Dec

3.  An automatic beat detection algorithm for pressure signals.

Authors:  Mateo Aboy; James McNames; Tran Thong; Daniel Tsunami; Miles S Ellenby; Brahm Goldstein
Journal:  IEEE Trans Biomed Eng       Date:  2005-10       Impact factor: 4.538

4.  Blood pressure variability remains an elusive predictor of cardiovascular outcome.

Authors:  Tine W Hansen; Yan Li; Jan A Staessen
Journal:  Am J Hypertens       Date:  2009-01       Impact factor: 2.689

5.  A comparison of the noise sensitivity of nine QRS detection algorithms.

Authors:  G M Friesen; T C Jannett; M A Jadallah; S L Yates; S R Quint; H T Nagle
Journal:  IEEE Trans Biomed Eng       Date:  1990-01       Impact factor: 4.538

Review 6.  Noninvasive haemodynamic monitoring using finger arterial pressure waveforms.

Authors:  R M de Jong; B E Westerhof; A A Voors; D J van Veldhuisen
Journal:  Neth J Med       Date:  2009-12       Impact factor: 1.422

Review 7.  Blood pressure variability. Importance in research and in clinical hypertension.

Authors:  G Parati; A Frattola; M Di Rienzo; G Mancia
Journal:  Arq Bras Cardiol       Date:  1996-08       Impact factor: 2.000

8.  Quantitative investigation of QRS detection rules using the MIT/BIH arrhythmia database.

Authors:  P S Hamilton; W J Tompkins
Journal:  IEEE Trans Biomed Eng       Date:  1986-12       Impact factor: 4.538

9.  A digital filter for the QRS complex detection.

Authors:  M Okada
Journal:  IEEE Trans Biomed Eng       Date:  1979-12       Impact factor: 4.538

10.  A real-time pressure algorithm.

Authors:  P Kinias; H A Fozzard; M J Norusis
Journal:  Comput Biol Med       Date:  1981       Impact factor: 4.589

View more
  1 in total

Review 1.  Journal of Clinical Monitoring and Computing 2016 end of year summary: cardiovascular and hemodynamic monitoring.

Authors:  Bernd Saugel; Karim Bendjelid; Lester A Critchley; Steffen Rex; Thomas W L Scheeren
Journal:  J Clin Monit Comput       Date:  2017-01-07       Impact factor: 2.502

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.