PURPOSE: To evaluate clinical safety and effectiveness of a novel calcium-incorporated titanium implant surface (Xpeed, MegaGen Implant Co., Gyeongbuk, South Korea). MATERIALS AND METHODS:Sixty patients were randomised to receive one to six implants in the maxilla with either calcium-incorporated (Xpeed) or control resorbable blasted media (RBM) surfaces, according to a parallel group design at two centres. Implants were submerged and exposed at three different endpoints in equal groups of 20 patients, each at 12, 10 and 8 weeks, respectively. Within 2 weeks, implants were functionally loaded with provisional or definitive prostheses. Outcome measures were prosthesis failures, implant failures, any complications and peri-implant marginal bone level changes. RESULTS: Thirty patients received 45 calcium-incorporated implants and 30 patients received 42 control titanium implants. Three years after loading four patients dropped-out from the Xpeed group and one from the RBM group. No prosthesis or implant failures occurred. There were no statistically significant differences between the groups for complications (P = 0.91; difference in proportions = 0.79 %; 95% CI -0.71 to 2.29) and mean marginal bone level changes (P = 0.88; mean difference = -0.02 mm; 95% CI -0.26 to 0.22). CONCLUSIONS: Both implant surfaces provided good clinical results and no significant difference was found when comparing titanium implants with a nanostructured calcium-incorporated surface versus implants with RBM surfaces.
RCT Entities:
PURPOSE: To evaluate clinical safety and effectiveness of a novel calcium-incorporated titanium implant surface (Xpeed, MegaGen Implant Co., Gyeongbuk, South Korea). MATERIALS AND METHODS: Sixty patients were randomised to receive one to six implants in the maxilla with either calcium-incorporated (Xpeed) or control resorbable blasted media (RBM) surfaces, according to a parallel group design at two centres. Implants were submerged and exposed at three different endpoints in equal groups of 20 patients, each at 12, 10 and 8 weeks, respectively. Within 2 weeks, implants were functionally loaded with provisional or definitive prostheses. Outcome measures were prosthesis failures, implant failures, any complications and peri-implant marginal bone level changes. RESULTS: Thirty patients received 45 calcium-incorporated implants and 30 patients received 42 control titanium implants. Three years after loading four patients dropped-out from the Xpeed group and one from the RBM group. No prosthesis or implant failures occurred. There were no statistically significant differences between the groups for complications (P = 0.91; difference in proportions = 0.79 %; 95% CI -0.71 to 2.29) and mean marginal bone level changes (P = 0.88; mean difference = -0.02 mm; 95% CI -0.26 to 0.22). CONCLUSIONS: Both implant surfaces provided good clinical results and no significant difference was found when comparing titanium implants with a nanostructured calcium-incorporated surface versus implants with RBM surfaces.
Authors: Matteo Albertini; Federico Herrero-Climent; Carmen María Díaz-Castro; Jose Nart; Ana Fernández-Palacín; José Vicente Ríos-Santos; Mariano Herrero-Climent Journal: Int J Environ Res Public Health Date: 2021-01-29 Impact factor: 3.390
Authors: Carlo Mangano; Jamil Awad Shibli; Jefferson Trabach Pires; Giuseppe Luongo; Adriano Piattelli; Giovanna Iezzi Journal: Biomed Res Int Date: 2017-02-09 Impact factor: 3.411