Literature DB >> 26352562

SMILE Procedures With Four Different Cap Thicknesses for the Correction of Myopia and Myopic Astigmatism.

Jose L Güell, Paula Verdaguer, Gloria Mateu-Figueras, Daniel Elies, Oscar Gris, Mostafa A El Husseiny, Felicidad Manero, Mercè Morral.   

Abstract

PURPOSE: To study the feasibility of performing myopic femtosecond small incision lenticule extraction (SMILE) with four different cap thicknesses (130, 140, 150, and 160 μm).
METHODS: In this retrospective, comparative, non-randomized clinical trial, a refractive lenticule of intrastromal corneal tissue was cut with the VisuMax femtosecond laser system (Carl Zeiss Meditec AG, Jena, Germany) using different depths of the non-refractive lenticule cut. Manifest refraction, uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), and Objective Scattering Index (OSI) were evaluated. Minimum follow-up time was 1 year.
RESULTS: Ninety-four eyes of 47 patients with myopia with (14 patients) and without (33 patients) astigmatism were treated. One year after the surgery, mean log-MAR UDVA, logMAR CDVA, SE, and OSI were 0.07 ± 0.12, 0.01 ± 0.37, 0.07 ± 0.57, and 0.88 ± 0.17, respectively (P < .05). There were no significant statistical differences in logMAR UDVA, logMAR CDVA, SE, or OSI (P > .05) variables when the different groups were compared for the same periods of time.
CONCLUSIONS: No differences in visual acuity, refractive outcomes in optical visual quality, or complications were observed when using SMILE at four different depths. Copyright 2015, SLACK Incorporated.

Entities:  

Mesh:

Year:  2015        PMID: 26352562     DOI: 10.3928/1081597X-20150820-02

Source DB:  PubMed          Journal:  J Refract Surg        ISSN: 1081-597X            Impact factor:   3.573


  7 in total

1.  Cap morphology after small-incision lenticule extraction and its effects on intraocular scattering.

Authors:  Dan Fu; Lin Wang; Xing-Tao Zhou; Zhi-Qiang Yu
Journal:  Int J Ophthalmol       Date:  2018-03-18       Impact factor: 1.779

2.  Mechanisms of corneal intrastromal laser dissection for refractive surgery: ultra-high-speed photographic investigation at up to 50 million frames per second.

Authors:  Sebastian Freidank; Alfred Vogel; Norbert Linz
Journal:  Biomed Opt Express       Date:  2022-04-26       Impact factor: 3.562

3.  Comparison of visual outcomes between 120-µm and 140-µm cap thicknesses 12 months after small incision lenticule extraction.

Authors:  Mehmet Gülmez; Özlem Ural Fatihoğlu; Abdülhakim Tekçe
Journal:  Lasers Med Sci       Date:  2022-02-26       Impact factor: 2.555

4.  Correction of hyperopia by intrastromal cutting and liquid filler injection.

Authors:  Sebastian Freidank; Alfred Vogel; R Rox Anderson; Reginald Birngruber; Norbert Linz
Journal:  J Biomed Opt       Date:  2019-05       Impact factor: 3.170

5.  Comparison of Two Cap Thickness in Small Incision Lenticule Extraction: 100μm versus 160μm.

Authors:  Miao He; Wei Wang; Hui Ding; Xingwu Zhong
Journal:  PLoS One       Date:  2016-09-21       Impact factor: 3.240

6.  Effect of Cap-Lenticule Diameter Difference on the Visual Outcome and Higher-Order Aberrations in SMILE: 0.4 mm versus 1.0 mm.

Authors:  Banu Torun Acar; Suphi Acar
Journal:  J Ophthalmol       Date:  2017-11-15       Impact factor: 1.909

7.  Optical Vortex Beam for Gentle and Ultraprecise Intrastromal Corneal Dissection in Refractive Surgery.

Authors:  Sebastian Freidank; Alfred Vogel; Norbert Linz
Journal:  Transl Vis Sci Technol       Date:  2020-09-23       Impact factor: 3.283