Literature DB >> 26351930

Comparison of functional fibrinogen (FF/CFF) and FIBTEM in surgical patients - a retrospective study.

Florian Prüller, Andreas Münch, Astrid Preininger, Reinhard Bernd Raggam, Yvonne Grinschgl, Jakub Krumnikl, Wolfgang Toller, Hellfried Metzler, Elisabeth Mahla, Harald Mangge.   

Abstract

BACKGROUND: Fibrinogen-based clot firmness is reported as the maximum amplitude (MA) when using the citrated functional fibrinogen (CFF) assay in thrombelastography (TEG), and as the maximum clot firmness (MCF) together with several clot amplitude parameters when using the FIBTEM assay in thromboelastometry (ROTEM). Concern is currently being raised that these two tests have different platelet inhibiting performance and consequently provide different values. This is relevant for the clinical setting of fibrinogen replacement. We aim herein to compare the parameters of these two fibrinogen-based clot quality tests and their correlation with the plasma fibrinogen level as determined by the Clauss method.
METHODS: In total 261 whole blood samples taken from 163 clinical routine surgical patients were analyzed with TEG 5000 and ROTEM tests, and correlation with Clauss fibrinogen level was assessed.
RESULTS: Using TEG, the overall fibrin-based clot firmness measured in the CFF assay was significantly higher than the MCF measured by FIBTEM assay. Both assays showed significantly positive correlations with the fibrinogen levels measured using the Clauss method. However, individual values of Clauss fibrinogen concentration corresponded with different values for the two viscoelastometric tests; e.g. within the range of 1.9-2.1 g/L Clauss fibrinogen the median of CFF MA was 16.3 mm whereas FIBTEM MCF was 12.0 mm.
CONCLUSIONS: We showed herein by measurements of citrated whole blood samples from surgical patients that CFF MA values were different from FIBTEM MCF values measured in the same sample. Awareness that these whole blood assays provide different clot amplitude results is mandatory, particularly if they are being considered as tools for guiding fibrinogen supplementation. Thromboembolic side effects caused by a potentially too high fibrinogen substitution must also kept in mind in this context.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 26351930     DOI: 10.1515/cclm-2015-0345

Source DB:  PubMed          Journal:  Clin Chem Lab Med        ISSN: 1434-6621            Impact factor:   3.694


  4 in total

1.  Correlation of plasma coagulation tests and fibrinogenClauss with rotational thromboelastometry parameters and prediction of bleeding in dogs.

Authors:  Nathalie M Enk; Annette P N Kutter; Claudia Kuemmerle-Fraune; Nadja E Sigrist
Journal:  J Vet Intern Med       Date:  2018-12-11       Impact factor: 3.333

2.  Correlations between rotational thromboelastometry (ROTEM) and standard coagulation tests following viper snakebites.

Authors:  Xuan Thi Dang; Thanh Xuan Nguyen; Huong Thi Thu Nguyen; Hung Tran Ha
Journal:  J Int Med Res       Date:  2022-01       Impact factor: 1.671

3.  TEG6s Platelet Mapping assay for the estimation of plasma fibrinogen concentration during cardiovascular surgery: a single-center prospective observational study.

Authors:  Yudai Yamamoto; Yunosuke Sato; Miri Takahashi; Hiroto Yamamoto; Mayumi Echizen; Tokujiro Uchida
Journal:  J Anesth       Date:  2021-10-13       Impact factor: 2.078

Review 4.  Thromboelastography and Thromboelastometry in Assessment of Fibrinogen Deficiency and Prediction for Transfusion Requirement: A Descriptive Review.

Authors:  Henry T Peng; Bartolomeu Nascimento; Andrew Beckett
Journal:  Biomed Res Int       Date:  2018-11-25       Impact factor: 3.411

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.