Literature DB >> 26340436

Gd(III)-Gd(III) distance measurements with chirp pump pulses.

Andrin Doll1, Mian Qi2, Nino Wili1, Stephan Pribitzer1, Adelheid Godt2, Gunnar Jeschke3.   

Abstract

The broad EPR spectrum of Gd(III) spin labels restricts the dipolar modulation depth in distance measurements between Gd(III) pairs to a few percent. To overcome this limitation, frequency-swept chirp pulses are utilized as pump pulses in the DEER experiment. Using a model system with 3.4 nm Gd-Gd distance, application of one single chirp pump pulse at Q-band frequencies leads to modulation depths beyond 10%. However, the larger modulation depth is counteracted by a reduction of the absolute echo intensity due to the pump pulse. As supported by spin dynamics simulations, this effect is primarily driven by signal loss to double-quantum coherence and specific to the Gd(III) high spin state of S=7/2. In order to balance modulation depth and echo intensity for optimum sensitivity, a simple experimental procedure is proposed. An additional improvement by 25% in DEER sensitivity is achieved with two consecutive chirp pump pulses. These pulses pump the Gd(III) spectrum symmetrically around the observation position, therefore mutually compensating for dynamical Bloch-Siegert phase shifts at the observer spins. The improved sensitivity of the DEER data with modulation depths on the order of 20% is due to mitigation of the echo reduction effects by the consecutive pump pulses. In particular, the second pump pulse does not lead to additional signal loss if perfect inversion is assumed. Moreover, the compensation of the dynamical Bloch-Siegert phase prevents signal loss due to spatial dependence of the dynamical phase, which is caused by inhomogeneities in the driving field. The new methodology is combined with pre-polarization techniques to measure long distances up to 8.6 nm, where signal intensity and modulation depth become attenuated by long dipolar evolution windows. In addition, the influence of the zero-field splitting parameters on the echo intensity is studied with simulations. Herein, larger sensitivity is anticipated for Gd(III) complexes with zero-field splitting that is smaller than for the employed Gd-PyMTA complex.
Copyright © 2015 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Chirp pulses; Distance measurements; Sensitivity enhancement

Mesh:

Substances:

Year:  2015        PMID: 26340436     DOI: 10.1016/j.jmr.2015.08.010

Source DB:  PubMed          Journal:  J Magn Reson        ISSN: 1090-7807            Impact factor:   2.229


  14 in total

1.  Photonic band-gap resonators for high-field/high-frequency EPR of microliter-volume liquid aqueous samples.

Authors:  Sergey Milikisiyants; Alexander A Nevzorov; Alex I Smirnov
Journal:  J Magn Reson       Date:  2018-09-20       Impact factor: 2.229

2.  Gd3+-Gd3+ distances exceeding 3 nm determined by very high frequency continuous wave electron paramagnetic resonance.

Authors:  Jessica A Clayton; Mian Qi; Adelheid Godt; Daniella Goldfarb; Songi Han; Mark S Sherwin
Journal:  Phys Chem Chem Phys       Date:  2017-02-15       Impact factor: 3.676

3.  Enhancing sensitivity of Double Electron-Electron Resonance (DEER) by using Relaxation-Optimized Acquisition Length Distribution (RELOAD) scheme.

Authors:  Sergey Milikisiyants; Maxim A Voinov; Antonin Marek; Morteza Jafarabadi; Jing Liu; Rong Han; Shenlin Wang; Alex I Smirnov
Journal:  J Magn Reson       Date:  2018-12-05       Impact factor: 2.229

4.  Coherent pump pulses in Double Electron Electron Resonance spectroscopy.

Authors:  Claudia E Tait; Stefan Stoll
Journal:  Phys Chem Chem Phys       Date:  2016-06-24       Impact factor: 3.676

5.  Integration of a versatile bridge concept in a 34 GHz pulsed/CW EPR spectrometer.

Authors:  Alan Band; Matthew P Donohue; Boris Epel; Shraeya Madhu; Veronika A Szalai
Journal:  J Magn Reson       Date:  2018-02-02       Impact factor: 2.229

6.  Two closed ATP- and ADP-dependent conformations in yeast Hsp90 chaperone detected by Mn(II) EPR spectroscopic techniques.

Authors:  Angeliki Giannoulis; Akiva Feintuch; Yoav Barak; Hisham Mazal; Shira Albeck; Tamar Unger; Feng Yang; Xun-Cheng Su; Daniella Goldfarb
Journal:  Proc Natl Acad Sci U S A       Date:  2019-12-20       Impact factor: 11.205

7.  Distance measurements between paramagnetic ligands bound to parallel stranded guanine quadruplexes.

Authors:  M P Donohue; V A Szalai
Journal:  Phys Chem Chem Phys       Date:  2016-06-01       Impact factor: 3.676

8.  In-cell destabilization of a homodimeric protein complex detected by DEER spectroscopy.

Authors:  Yin Yang; Shen-Na Chen; Feng Yang; Xia-Yan Li; Akiva Feintuch; Xun-Cheng Su; Daniella Goldfarb
Journal:  Proc Natl Acad Sci U S A       Date:  2020-08-11       Impact factor: 11.205

9.  Substrate binding in the multidrug transporter MdfA in detergent solution and in lipid nanodiscs.

Authors:  Thorsten Bahrenberg; Eliane Hadas Yardeni; Akiva Feintuch; Eitan Bibi; Daniella Goldfarb
Journal:  Biophys J       Date:  2021-03-24       Impact factor: 4.033

10.  DEER Sensitivity between Iron Centers and Nitroxides in Heme-Containing Proteins Improves Dramatically Using Broadband, High-Field EPR.

Authors:  Claire L Motion; Janet E Lovett; Stacey Bell; Scott L Cassidy; Paul A S Cruickshank; David R Bolton; Robert I Hunter; Hassane El Mkami; Sabine Van Doorslaer; Graham M Smith
Journal:  J Phys Chem Lett       Date:  2016-04-01       Impact factor: 6.475

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.