Literature DB >> 26336560

Feasibility and accuracy of a new mobile electrocardiography device, ER-2000(®), in the diagnosis of arrhythmia.

Yae Min Park1, Dae In Lee2, Hwan Cheol Park3, Jaemin Shim2, Jong-Il Choi2, Hong Euy Lim2, Sang Weon Park2, Young-Hoon Kim2.   

Abstract

BACKGROUND: We performed this study to evaluate the feasibility and accuracy of a new mobile electrocardiography (ECG) device, ER-2000(®), in detecting cardiac arrhythmia, by comparing it to a 12-lead ECG used as the gold standard.
METHODS: Mode 1 of ER-2000(®) was recorded using three electrodes with cables attached to the anterior chest wall, and mode 2 was recorded using the side chest channel and finger channel. Standard 12-lead ECG was used to record with a speed of 25 mm/s, simultaneously.
RESULTS: Seventeen patients with complaints of palpitation were enrolled. Twelve-lead ECG revealed normal sinus rhythm in three patients, sinus tachycardia in one, atrial fibrillation (AF) in two, atrial tachycardia (AT) in one, first degree atrioventricular block in one, pacing rhythm in two patients who underwent permanent pacemaker implantation, AF with intermittent ventricular pacing in one, complete right bundle branch block in one, J-wave elevation in one, narrow QRS tachycardia in one, atrial premature beat (APB) in one, ventricular premature beat (VPB) in one, and narrow QRS tachycardia with intermittent aberrant conduction in one. Rhythm diagnosis obtained by the two different modes of ER-2000(®) was correlated with that obtained by the 12-lead ECG in all patients except in one in whom ER-2000(®) showed one APB while 12-lead ECG showed sinus rhythm. R-R interval was accurately recorded despite the detailed morphology of QRS, and T-wave was somewhat modified with the use of ER-2000(®). A pacing blip detected by 12-lead ECG was not detected by ER-2000(®) despite a similar wide QRS duration in the paced QRS.
CONCLUSIONS: A rhythm strip obtained using ER-2000(®) is accurate in diagnosing arrhythmia, despite some differences in the detailed morphology of the QRS and T-wave, and the pacing spike compared to those obtained by the 12-lead ECG.

Entities:  

Keywords:  12-Lead electrocardiogram (ECG); Arrhythmia; ER-2000®

Year:  2015        PMID: 26336560      PMCID: PMC4555462          DOI: 10.1016/j.joa.2014.12.003

Source DB:  PubMed          Journal:  J Arrhythm        ISSN: 1880-4276


  7 in total

1.  Wireless remote monitoring of atrial fibrillation using reconstructed 12-lead ECGs.

Authors:  Dejan Vukajlovic; Bosko Bojovic; Ljupco Hadzievski; Samuel George; Ihor Gussak; Dorin Panescu
Journal:  Annu Int Conf IEEE Eng Med Biol Soc       Date:  2010

2.  Utility of patient-activated cardiac event recorders in general clinical practice.

Authors:  P Zimetbaum; K Y Kim; K K Ho; J Zebede; M E Josephson; A L Goldberger
Journal:  Am J Cardiol       Date:  1997-02-01       Impact factor: 2.778

3.  Prevalence and predictors of paroxysmal atrial fibrillation on Holter monitor in patients with stroke or transient ischemic attack.

Authors:  Osama Alhadramy; Thomas J Jeerakathil; Sumit R Majumdar; Emad Najjar; Jonathan Choy; Maher Saqqur
Journal:  Stroke       Date:  2010-10-14       Impact factor: 7.914

4.  Value of cardiac monitoring and echocardiography in TIA and stroke patients.

Authors:  J A Rem; V C Hachinski; D R Boughner; H J Barnett
Journal:  Stroke       Date:  1985 Nov-Dec       Impact factor: 7.914

5.  The dual role of implantable loop recorder in patients with potentially arrhythmic symptoms: a retrospective single-center study.

Authors:  Rajesh Kabra; Rakesh Gopinathannair; Chirag Sandesara; Catherine Messinger; Brian Olshansky
Journal:  Pacing Clin Electrophysiol       Date:  2009-07       Impact factor: 1.976

6.  Holter monitoring in patients with transient and focal ischemic attacks of the brain.

Authors:  P J Koudstaal; J van Gijn; A P Klootwijk; F G van der Meche; L J Kappelle
Journal:  Stroke       Date:  1986 Mar-Apr       Impact factor: 7.914

7.  Outpatient cardiac telemetry detects a high rate of atrial fibrillation in cryptogenic stroke.

Authors:  Daniel J Miller; Muhib A Khan; Lonni R Schultz; Jennifer R Simpson; Angelos M Katramados; Andrew N Russman; Panayiotis D Mitsias
Journal:  J Neurol Sci       Date:  2012-10-24       Impact factor: 3.181

  7 in total
  1 in total

1.  Testing MD-Link, a Low-Cost Mobile Electrocardiography Monitoring Device, in Patients With Irregular Heartbeat: Protocol for a Cross-Sectional Study.

Authors:  Precious J Kilimo; Tai Le; Ngoc T Phan; Huy-Dung Han; Hoc T Hoang; Nguyen C Vu; Nga Tt Pham; Hung Cao; Cuong K Nguyen
Journal:  JMIR Res Protoc       Date:  2019-01-31
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.