Literature DB >> 19572867

The dual role of implantable loop recorder in patients with potentially arrhythmic symptoms: a retrospective single-center study.

Rajesh Kabra1, Rakesh Gopinathannair, Chirag Sandesara, Catherine Messinger, Brian Olshansky.   

Abstract

BACKGROUND: Unexplained and potentially arrhythmic symptoms often lead to electrophysiology referral for evaluation. Implantable loop recorder (ILR) correlation of the symptom to the rhythm can secure a definitive arrhythmic diagnosis after a standard, yet nondiagnostic workup.
METHODS: This large single-center retrospective study sought to assess the role of ILR in the evaluation of potentially arrhythmic symptoms, both in terms of diagnosis of an arrhythmia as well as to rule out an arrhythmic cause. Clinical data, indications for ILR, interrogation reports, and further management strategies were collected in all 86 patients who received ILR from June 1999 to April 2008 at the University of Iowa Hospitals and Clinics. The indications for ILR were unexplained syncope (76%), palpitations (14%), and presyncope or dizziness (10%).
RESULTS: During a mean follow-up period of 10 +/- 7 months, 53 patients (62%) had recurrent symptoms after ILR placement with the mean time to recurrence of 12 +/- 17 weeks. Of these, an arrhythmic diagnosis was established in 12 patients (14%). Forty-one patients (48%) did not have any arrhythmia during their symptoms. These patients were discharged from the electrophysiology clinic. Thirty-three patients (38%) did not have any symptoms following ILR placement. Out of these, device was explanted in 10 patients, while the rest are still being followed.
CONCLUSIONS: In patients with potentially arrhythmic symptoms, ILR plays an important role not only in diagnosing an arrhythmia, but also to rule out an arrhythmic cause.

Entities:  

Mesh:

Year:  2009        PMID: 19572867     DOI: 10.1111/j.1540-8159.2009.02407.x

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  8 in total

1.  New real-time loop recorder diagnosis of symptomatic arrhythmia via telemedicine.

Authors:  Eran Leshem-Rubinow; Michael Berger; Jacob Shacham; Edo Y Birati; Nomi Malov; Mira Tamari; Michal Golovner; Arie Roth
Journal:  Clin Cardiol       Date:  2011-05-25       Impact factor: 2.882

Review 2.  Tilt table test today - state of the art.

Authors:  Nicholay Teodorovich; Moshe Swissa
Journal:  World J Cardiol       Date:  2016-03-26

3.  Feasibility and accuracy of a new mobile electrocardiography device, ER-2000(®), in the diagnosis of arrhythmia.

Authors:  Yae Min Park; Dae In Lee; Hwan Cheol Park; Jaemin Shim; Jong-Il Choi; Hong Euy Lim; Sang Weon Park; Young-Hoon Kim
Journal:  J Arrhythm       Date:  2015-01-13

4.  Improved quality of life after treatment of prolonged asystole during breath holding spells with a cardiac pacemaker.

Authors:  Bruno Kolterer; Roman Antonin Gebauer; Jan Janousek; Ingo Dähnert; Frank Thomas Riede; Christian Paech
Journal:  Ann Pediatr Cardiol       Date:  2015 May-Aug

Review 5.  Implantable Cardiac Monitors: Evolution Through Disruption.

Authors:  Chirag M Sandesara; Rakesh Gopinathannair; Brian Olshansky
Journal:  J Innov Card Rhythm Manag       Date:  2017-09-15

6.  Changes in R-wave amplitude at implantation are associated with gender and orientation of insertable cardiac monitor: observations from the confirm Rx™ body posture and physical activity study.

Authors:  Matthew Swale; Vincent Paul; Sinny Delacroix; Glenn Young; Luke McSpadden; Kyungmoo Ryu; David Di Fiore; Maria Santos; Isabel Tan; Andre Conradie; MyNgan Duong; Nisha Schwarz; Stephen Worthley; Stephen Pavia
Journal:  BMC Cardiovasc Disord       Date:  2022-10-08       Impact factor: 2.174

7.  Financial impact of adopting implantable loop recorder diagnostic for unexplained syncope compared with conventional diagnostic pathway in Portugal.

Authors:  Rui Providência; Rui Candeias; Carlos Morais; Hipólito Reis; Luís Elvas; Vitor Sanfins; Sara Farinha; Simon Eggington; Stelios Tsintzos
Journal:  BMC Cardiovasc Disord       Date:  2014-05-06       Impact factor: 2.298

8.  Diagnostic value of implantable loop recorders in patients with unexplained syncope or palpitations.

Authors:  Nikola N Radovanović; Siniša U Pavlović; Bratislav Kirćanski; Nemanja Branković; Nikola Vujadinović; Vojislav Sajić; Ana Milašinović; Vesna Bisenić; Mirjana Živković; Goran Milašinović
Journal:  Ann Noninvasive Electrocardiol       Date:  2021-06-07       Impact factor: 1.468

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.