Dosimetric Comparison Between 3-Dimensional Conformal and Robotic SBRT Treatment Plans for Accelerated Partial Breast Radiotherapy.

L M Goggin1, M Descovich2, C McGuinness2, S Shiao2, J Pouliot2, C Park2.   

Abstract

Accelerated partial breast irradiation is an attractive alternative to conventional whole breast radiotherapy for selected patients. Recently, CyberKnife has emerged as a possible alternative to conventional techniques for accelerated partial breast irradiation. In this retrospective study, we present a dosimetric comparison between 3-dimensional conformal radiotherapy plans and CyberKnife plans using circular (Iris) and multi-leaf collimators. Nine patients who had undergone breast-conserving surgery followed by whole breast radiation were included in this retrospective study. The CyberKnife planning target volume (PTV) was defined as the lumpectomy cavity + 10 mm + 2 mm with prescription dose of 30 Gy in 5 fractions. Two sets of 3-dimensional conformal radiotherapy plans were created, one used the same definitions as described for CyberKnife and the second used the RTOG-0413 definition of the PTV: lumpectomy cavity + 15 mm + 10 mm with prescription dose of 38.5 Gy in 10 fractions. Using both PTV definitions allowed us to compare the dose delivery capabilities of each technology and to evaluate the advantage of CyberKnife tracking. For the dosimetric comparison using the same PTV margins, CyberKnife and 3-dimensional plans resulted in similar tumor coverage and dose to critical structures, with the exception of the lung V5%, which was significantly smaller for 3-dimensional conformal radiotherapy, 6.2% when compared to 39.4% for CyberKnife-Iris and 17.9% for CyberKnife-multi-leaf collimator. When the inability of 3-dimensional conformal radiotherapy to track motion is considered, the result increased to 25.6%. Both CyberKnife-Iris and CyberKnife-multi-leaf collimator plans demonstrated significantly lower average ipsilateral breast V50% (25.5% and 24.2%, respectively) than 3-dimensional conformal radiotherapy (56.2%). The CyberKnife plans were more conformal but less homogeneous than the 3-dimensional conformal radiotherapy plans. Approximately 50% shorter treatment times and 50% lower number of delivered monitor units (MU) were achievable with CyberKnife-multi-leaf collimator than with CyberKnife-Iris. The CyberKnife-multi-leaf collimator treatment times were comparable to 3-dimensional conformal radiotherapy, however, the number of MU delivered was approximately 2.5 times larger. The suitability of 10 + 2 mm margins warrants further investigation.
© The Author(s) 2015.

Entities:  

Keywords:  3D-conformal radiotherapy; breast cancer; robotic; stereotactic body radiation therapy; stereotactic radiotherapy

Mesh:

Year:  2015        PMID: 26335703     DOI: 10.1177/1533034615601280

Source DB:  PubMed          Journal:  Technol Cancer Res Treat        ISSN: 1533-0338


  5 in total

1.  Radiotoxicity in robotic radiosurgery: proposing a new quality index for optimizing the treatment planning of brain metastases.

Authors:  Alexandra Hellerbach; Klaus Luyken; Mauritius Hoevels; Andreas Gierich; Daniel Rueß; Wolfgang W Baus; Martin Kocher; Maximilian I Ruge; Harald Treuer
Journal:  Radiat Oncol       Date:  2017-08-17       Impact factor: 3.481

2.  Partial breast irradiation with CyberKnife after breast conserving surgery: a pilot study in early breast cancer.

Authors:  Laura Lozza; Laura Fariselli; Marco Sandri; Mario Rampa; Valentina Pinzi; Maria Carmen De Santis; Marzia Franceschini; Giovanna Trecate; Ilaria Maugeri; Luisa Fumagalli; Francesca Bonfantini; Giulia Bianchi; Emanuele Pignoli; Elena De Martin; Roberto Agresti
Journal:  Radiat Oncol       Date:  2018-03-23       Impact factor: 3.481

3.  Conventionally fractionated large volume head and neck re-irradiation using multileaf collimator-based robotic technique: A feasibility study.

Authors:  Houda Bahig; Catherine Wang; Sweet Ping Ng; Jack Phan
Journal:  Clin Transl Radiat Oncol       Date:  2020-07-02

4.  Multicatheter interstitial brachytherapy versus stereotactic radiotherapy with CyberKnife for accelerated partial breast irradiation: a comparative treatment planning study with respect to dosimetry of organs at risk.

Authors:  András Herein; Gábor Stelczer; Csilla Pesznyák; Georgina Fröhlich; Viktor Smanykó; Norbert Mészáros; Csaba Polgár; Tibor Major
Journal:  Radiol Oncol       Date:  2021-03-25       Impact factor: 2.991

5.  CyberKnife versus multicatheter interstitial brachytherapy for accelerated partial breast irradiation: a dosimetrical assessment with focus on organs at risk.

Authors:  András Herein; Gábor Stelczer; Csilla Pesznyák; Georgina Fröhlich; Viktor Smanykó; Norbert Mészáros; Csaba Polgár; Zoltán Takácsi-Nagy; Tibor Major
Journal:  Rep Pract Oncol Radiother       Date:  2022-03-22