Francisco Contijoch1, Walter R T Witschey2, Kelly Rogers1, Joseph Gorman3, Robert C Gorman3, Victor Ferrari4, Yuchi Han4. 1. Department of Bioengineering, University of Pennsylvania, PA, Pennsylvania, USA. 2. Hospital of the University of Pennsylvania, Department of Radiology, Philadelphia, Pennsylvania, USA. 3. Hospital of the University of Pennsylvania, Department of Surgery, Philadelphia, Pennsylvania, USA. 4. Hospital of the University of Pennsylvania, Cardiovascular Division, Philadelphia, Pennsylvania, USA.
Abstract
PURPOSE: To evaluate the impact of end-diastolic (ED) and end-systolic (ES) cardiac phase selection methods, since task force recommendations have neither provided quantitative evidence nor explored errors introduced by clinical shortcuts. MATERIALS AND METHODS: Multislice, short-axis cine images were collected in 60 clinical patients on a 1.5T scanner. User-initialized active contour segmentation software quantified global left ventricular (LV) volume across all cardiac phases. Different approaches for selection of ED and ES phase were evaluated by quantification of temporal and volumetric errors. RESULTS: For diastole, the mid-ventricular maximum slice volume coincided with maximum global volume in 82.1% of patients with ejection fraction (EF) ≥55% (P = 0.66) and 71.9% of patients with EF <55% (P = 0.28) and is an accurate approximation of maximum global volume while the first and last phases in a retrospectively electrocardiogram (ECG)-gated acquisition introduced differences in cardiac phase selection (P < 0.001) which led to large errors in measured volume in some patients (12.7 and 10.1 mL, respectively). For systole, post-systolic shortening occurred in a significantly higher number of patients with EF <55% (18.9%) compared to 3.6% of patients with EF ≥55% (P = 0.001), which differentially impacted end-systolic volume estimation. CONCLUSION: For end-diastolic phase selection, our results indicated that the use of the mid-ventricular slice volume maximum provided accurate volume estimates, while selection of the first or last cardiac phase introduced differences in measured volume. For end-systolic phase, patients with EF <55% had a higher prevalence of post-systolic shortening, which suggests aortic valve closure should be used to estimate end-systolic volume.
PURPOSE: To evaluate the impact of end-diastolic (ED) and end-systolic (ES) cardiac phase selection methods, since task force recommendations have neither provided quantitative evidence nor explored errors introduced by clinical shortcuts. MATERIALS AND METHODS: Multislice, short-axis cine images were collected in 60 clinical patients on a 1.5T scanner. User-initialized active contour segmentation software quantified global left ventricular (LV) volume across all cardiac phases. Different approaches for selection of ED and ES phase were evaluated by quantification of temporal and volumetric errors. RESULTS: For diastole, the mid-ventricular maximum slice volume coincided with maximum global volume in 82.1% of patients with ejection fraction (EF) ≥55% (P = 0.66) and 71.9% of patients with EF <55% (P = 0.28) and is an accurate approximation of maximum global volume while the first and last phases in a retrospectively electrocardiogram (ECG)-gated acquisition introduced differences in cardiac phase selection (P < 0.001) which led to large errors in measured volume in some patients (12.7 and 10.1 mL, respectively). For systole, post-systolic shortening occurred in a significantly higher number of patients with EF <55% (18.9%) compared to 3.6% of patients with EF ≥55% (P = 0.001), which differentially impacted end-systolic volume estimation. CONCLUSION: For end-diastolic phase selection, our results indicated that the use of the mid-ventricular slice volume maximum provided accurate volume estimates, while selection of the first or last cardiac phase introduced differences in measured volume. For end-systolic phase, patients with EF <55% had a higher prevalence of post-systolic shortening, which suggests aortic valve closure should be used to estimate end-systolic volume.
Authors: Khaled Alfakih; Sven Plein; Holger Thiele; Tim Jones; John P Ridgway; Mohan U Sivananthan Journal: J Magn Reson Imaging Date: 2003-03 Impact factor: 4.813
Authors: Paul A Yushkevich; Joseph Piven; Heather Cody Hazlett; Rachel Gimpel Smith; Sean Ho; James C Gee; Guido Gerig Journal: Neuroimage Date: 2006-03-20 Impact factor: 6.556
Authors: Shunsuke Natori; Shenghan Lai; J Paul Finn; Antoinette S Gomes; W Gregory Hundley; Michael Jerosch-Herold; Gregory Pearson; Shantanu Sinha; Andrew Arai; Joao A C Lima; David A Bluemke Journal: AJR Am J Roentgenol Date: 2006-06 Impact factor: 3.959
Authors: Walter R T Witschey; Francisco Contijoch; Jeremy R McGarvey; Victor A Ferrari; Michael S Hansen; Madonna E Lee; Satoshi Takebayashi; Chikashi Aoki; Julio A Chirinos; Paul A Yushkevich; Joseph H Gorman; James J Pilla; Robert C Gorman Journal: Ann Thorac Surg Date: 2014-03-12 Impact factor: 4.330
Authors: Francisco Contijoch; Walter R T Witschey; Kelly Rogers; Hannah Rears; Michael Hansen; Paul Yushkevich; Joseph Gorman; Robert C Gorman; Yuchi Han Journal: J Cardiovasc Magn Reson Date: 2015-05-21 Impact factor: 5.364
Authors: Francisco Contijoch; Srikant Kamesh Iyer; James J Pilla; Paul Yushkevich; Joseph H Gorman; Robert C Gorman; Harold Litt; Yuchi Han; Walter R T Witschey Journal: Magn Reson Med Date: 2016-08-31 Impact factor: 4.668
Authors: Antonildes Nascimento Assuncao-Jr; Roberto Nery Dantas-Jr; Renata Margarida do Val; Priscilla Gianotto; Angela Dos Santos Marin; Mark Golden; Marco Antonio Gutierrez; Jose Rodrigues Parga; Cesar Higa Nomura Journal: Insights Imaging Date: 2019-06-13