Literature DB >> 26330584

Revision total hip arthroplasty after removal of a fractured well-fixed extensively porous-coated femoral component using a trephine.

D F Amanatullah1, H Siman2, G D Pallante2, D B Haber3, R J Sierra2, R T Trousdale2.   

Abstract

When fracture of an extensively porous-coated femoral component occurs, its removal at revision total hip arthroplasty (THA) may require a femoral osteotomy and the use of a trephine. The remaining cortical bone after using the trephine may develop thermally induced necrosis. A retrospective review identified 11 fractured, well-fixed, uncemented, extensively porous-coated femoral components requiring removal using a trephine with a minimum of two years of follow-up. The mean time to failure was 4.6 years (1.7 to 9.1, standard deviation (sd) 2.3). These were revised using a larger extensively porous coated component, fluted tapered modular component, a proximally coated modular component, or a proximal femoral replacement. The mean clinical follow-up after revision THA was 4.9 years (2 to 22, sd 3.1). The mean diameter of the femoral component increased from 12.7 mm (sd 1.9) to 16.2 mm (sd 3.4; p > 0.001). Two revision components had radiographic evidence of subsidence that remained radiographically stable at final follow-up. The most common post-operative complication was instability affecting six patients (54.5%) on at least one occasion. A total of four patients (36.4%) required further revision: three for instability and one for fracture of the revision component. There was no statistically significant difference in the mean Harris hip score before implant fracture (82.4; sd 18.3) and after trephine removal and revision THA (81.2; sd 14.8, p = 0.918). These findings suggest that removal of a fractured, well-fixed, uncemented, extensively porous-coated femoral component using a trephine does not compromise subsequent fixation at revision THA and the patient's pre-operative level of function can be restored. However, the loss of proximal bone stock before revision may be associated with a high rate of dislocation post-operatively. ©2015 The British Editorial Society of Bone & Joint Surgery.

Entities:  

Keywords:  Femoral component fracture; Porous-coated; Revision THA; Trephine; Uncemented

Mesh:

Substances:

Year:  2015        PMID: 26330584     DOI: 10.1302/0301-620X.97B9.35037

Source DB:  PubMed          Journal:  Bone Joint J        ISSN: 2049-4394            Impact factor:   5.082


  2 in total

1.  Distal non-traumatic fracture of the cementless MP stem: A case report and review of previous reported cases.

Authors:  Hussein Abdelaziz; Christian Ansorge; Thorsten Gehrke; Mustafa Citak
Journal:  J Clin Orthop Trauma       Date:  2019-07-30

2.  Removal of an osteointegrated broken uncemented femoral stem after hip arthroplasty-technical note.

Authors:  Peter Wahl; Theo Solinger; Michel Schläppi; Emanuel Gautier
Journal:  J Orthop Surg Res       Date:  2021-03-26       Impact factor: 2.359

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.