Literature DB >> 26330583

Metal-on-polyethylene versus metal-on-metal bearing surfaces in total hip arthroplasty: a prospective randomised study investigating metal ion levels and chromosomal aberrations in peripheral lymphocytes.

T W R Briggs1, S A Hanna2, B Kayani1, S Tai3, R C Pollock1, S R Cannon1, G W Blunn4, R W J Carrington1.   

Abstract

The long term biological effects of wear products following total hip arthroplasty (THA) are unclear. However, the indications for THA are expanding, with increasingly younger patients undergoing the procedure. This prospective, randomised study compared two groups of patients undergoing THA after being randomised to receive one of two different bearing surfaces: metal-on-polyethylene (MoP) n = 22 and metal-on-metal (MoM) n = 23. We investigated the relationship between three variables: bearing surface (MoP vs MoM), whole blood levels of chromium (Cr) and cobalt (Co) and chromosomal aberrations in peripheral lymphocyte pre-operatively and at one, two and five years post-surgery. Our results demonstrated significantly higher mean cobalt and chromium (Co and Cr) blood levels in the MoM group at all follow-up points following surgery (p < 0.01), but there were no significant differences in the chromosomal aberration indices between MoM and MoP at two or five years (two years: p = 0.56, p = 0.08, p = 0.91, p = 0.51 and five years: p = 0.086, p = 0.73, p = 0.06, p = 0.34) for translocations, breaks, loss and gain of chromosomes respectively. Regression analysis showed a strong linear relationship between Cr levels and the total chromosomal aberration indices in the MoM group (R(2) = 0.90016), but this was not as strong for Co (R(2) = 0.68991). In the MoP group, the analysis revealed a poor relationship between Cr levels and the total chromosomal aberration indices (R(2) = 0.23908) but a slightly stronger relationship for Co (R(2) = 0.64292). Across both groups, Spearman's correlation detected no overall association between Co and Cr levels and each of the studied chromosomal aberrations. There remains no clear indication which THA bearing couple is the most biocompatible, especially in young active patients. While THA continues to be very successful at alleviating pain and restoring function, the long-term biological implications of the procedure still require further scrutiny. ©2015 The British Editorial Society of Bone & Joint Surgery.

Entities:  

Keywords:  Chromosomes; Hip; Ions; Metal; Polyethylene; Replacement

Mesh:

Substances:

Year:  2015        PMID: 26330583     DOI: 10.1302/0301-620X.97B9.34824

Source DB:  PubMed          Journal:  Bone Joint J        ISSN: 2049-4394            Impact factor:   5.082


  5 in total

1.  High blood metal ion levels in 19 of 22 patients with metal-on-metal hinge knee replacements.

Authors:  Minna Laitinen; Jyrki Nieminen; Aleksi Reito; Toni-Karri Pakarinen; Piia Suomalainen; Konsta Pamilo; Jyrki Parkkinen; Tonis Lont; Antti Eskelinen
Journal:  Acta Orthop       Date:  2017-01-26       Impact factor: 3.717

2.  Psychiatric Disorders and Genotoxicity Following Primary Metal on Polyethylene Total Hip Arthroplasty and Their Correlation to Cobalt/Chromium Levels.

Authors:  Omaima I Abdel Hamid; Mohamed E Attia; Jon M Hirshon; Mohamed El-Shinawi; Moustafa El-Hussaini; Maged El-Setouhy
Journal:  Drug Healthc Patient Saf       Date:  2022-07-18

3.  Nickel contamination after minimally-invasive repair of pectus excavatum persists after bar removal.

Authors:  Caroline Fortmann; Thomas Goeen; Norman Zinne; Soeren Wiesner; Benno M Ure; Claus Petersen; Joachim F Kuebler
Journal:  PLoS One       Date:  2022-10-10       Impact factor: 3.752

Review 4.  Increased Mortality in Metal-on-Metal versus Non-Metal-on-Metal Primary Total Hip Arthroplasty at 10 Years and Longer Follow-Up: A Systematic Review and Meta-Analysis.

Authors:  B G Pijls; J M T A Meessen; J W Schoones; M Fiocco; H J L van der Heide; A Sedrakyan; R G H H Nelissen
Journal:  PLoS One       Date:  2016-06-13       Impact factor: 3.240

5.  No association between blood count levels and whole-blood cobalt and chromium levels in 1,900 patients with metal-on-metal hip arthroplasty.

Authors:  Noora Honkasaari; Olli Lainiala; Outi Laine; Aleksi Reito; Antti Eskelinen
Journal:  Acta Orthop       Date:  2020-10-02       Impact factor: 3.717

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.