Literature DB >> 26327207

Comparison, association, and risk assessment of phthalates in floor dust at different indoor environments in Delaware, USA.

Xiaolong Bi1,2, Shoujun Yuan3, Xiaojun Pan2, Cherese Winstead1, Qiquan Wang1.   

Abstract

This study aimed to compare and assess phthalate contamination in various indoor environments. In this study, 44 floor dust samples from different indoor environments in Delaware, USA were collected and analyzed for 14 phthalates using gas chromatography-mass spectrometry. Phthalates were detected in all dust samples with the total concentration ranging from 84 to 7117 mg kg(-1). DEHP (di-2-ethylhexyl phthalate), BzBP (benzylbutyl phthalate), DBP (dibutyl phthalate), and DiBP (di-isobutyl phthalate) were both the most frequently and abundantly detected phthalates. The average concentration of total phthalates in dust from offices, student dorms, gyms, stores, and daycare centers was found to be significantly or insignificantly (P = 0.05) higher than that in dust from houses and apartments. Plastic flooring materials and the application of floor care chemical products were positively associated with total phthalate concentration in floor dust. Toxicological risk assessment indicated that an investigated daycare center in this study was the only indoor environment that may cause the intake amount of DEHP of infants, toddlers, and children via dust ingestion to exceed the reference dose established by the U.S. Environmental Protection Agency (USEPA). Regular monitoring on phthalate contamination in sensitive indoor environments is recommended.

Entities:  

Keywords:  Floor dust; GC-MS; indoor environment; phthalate; plasticizer; risk assessment

Mesh:

Substances:

Year:  2015        PMID: 26327207     DOI: 10.1080/10934529.2015.1074482

Source DB:  PubMed          Journal:  J Environ Sci Health A Tox Hazard Subst Environ Eng        ISSN: 1093-4529            Impact factor:   2.269


  2 in total

1.  Concentration of phthalate esters in indoor and outdoor dust in Kocaeli, Turkey: implications for human exposure and risk.

Authors:  Bilgehan Başaran; Gizem Nur Soylu; Mihriban Yılmaz Civan
Journal:  Environ Sci Pollut Res Int       Date:  2019-11-22       Impact factor: 4.223

2.  A Noncontact Dibutyl Phthalate Sensor Based on a Wireless-Electrodeless QCM-D Modified with Nano-Structured Nickel Hydroxide.

Authors:  Daqi Chen; Xiyang Sun; Kaihuan Zhang; Guokang Fan; You Wang; Guang Li; Ruifen Hu
Journal:  Sensors (Basel)       Date:  2017-07-21       Impact factor: 3.576

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.