Literature DB >> 26319216

Semiautomatic three-dimensional CT ventricular volumetry in patients with congenital heart disease: agreement between two methods with different user interaction.

Hyun Woo Goo1, Sang-Hyub Park2.   

Abstract

To assess agreement between two semi-automatic, three-dimensional (3D) computed tomography (CT) ventricular volumetry methods with different user interactions in patients with congenital heart disease. In 30 patients with congenital heart disease (median age 8 years, range 5 days-33 years; 20 men), dual-source, multi-section, electrocardiography-synchronized cardiac CT was obtained at the end-systolic (n = 22) and/or end-diastolic (n = 28) phase. Nineteen left ventricle end-systolic (LV ESV), 28 left ventricle end-diastolic (LV EDV), 22 right ventricle end-systolic (RV ESV), and 28 right ventricle end-diastolic volumes (RV EDV) were successfully calculated using two semi-automatic, 3D segmentation methods with different user interactions (high in method 1, low in method 2). The calculated ventricular volumes of the two methods were compared and correlated. A P value <0.05 was considered statistically significant. LV ESV (35.95 ± 23.49 ml), LV EDV (88.76 ± 61.83 ml), and RV ESV (46.87 ± 47.39 ml) measured by method 2 were slightly but significantly smaller than those measured by method 1 (41.25 ± 26.94 ml, 92.20 ± 62.69 ml, 53.61 ± 50.08 ml for LV ESV, LV EDV, and RV ESV, respectively; P ≤ 0.02). In contrast, no statistically significant difference in RV EDV (122.57 ± 88.57 ml in method 1, 123.83 ± 89.89 ml in method 2; P = 0.36) was found between the two methods. All ventricular volumes showed very high correlation (R = 0.978, 0.993, 0.985, 0.997 for LV ESV, LV EDV, RV ESV, and RV EDV, respectively; P < 0.001) between the two methods. In patients with congenital heart disease, 3D CT ventricular volumetry shows good agreement and high correlation between the two methods, but method 2 tends to slightly underestimate LV ESV, LV EDV, and RV ESV.

Entities:  

Keywords:  Cardiac CT; Comparative study; Congenital heart disease; Multi-detector row CT; Ventricular volumetry

Mesh:

Year:  2015        PMID: 26319216     DOI: 10.1007/s10554-015-0751-6

Source DB:  PubMed          Journal:  Int J Cardiovasc Imaging        ISSN: 1569-5794            Impact factor:   2.357


  27 in total

1.  Dual-source computed tomography for assessing cardiac function: a phantom study.

Authors:  Andreas H Mahnken; Herbert Bruder; Christoph Suess; Georg Mühlenbruch; Philipp Bruners; Christian Hohl; Rolf W Guenther; Joachim E Wildberger
Journal:  Invest Radiol       Date:  2007-07       Impact factor: 6.016

2.  Cardiac function by MRI in congenital heart disease: impact of consensus training on interinstitutional variance.

Authors:  Philipp Beerbaum; Peter Barth; Siegfried Kropf; Samir Sarikouch; Andrea Kelter-Kloepping; Diana Franke; Matthias Gutberlet; Titus Kuehne
Journal:  J Magn Reson Imaging       Date:  2009-11       Impact factor: 4.813

Review 3.  Cardiac MDCT in children: CT technology overview and interpretation.

Authors:  Hyun Woo Goo
Journal:  Radiol Clin North Am       Date:  2011-09       Impact factor: 2.303

4.  Left ventricle volume measured by cardiac CT in an infant with a small left ventricle: a new and accurate method in determining uni- or biventricular repair.

Authors:  Ho Jin Kim; Hyun Woo Goo; Sang-Hyub Park; Tae-Jin Yun
Journal:  Pediatr Radiol       Date:  2012-08-09

5.  Impact of right ventricular endocardial trabeculae on volumes and function assessed by CMR in patients with tetralogy of Fallot.

Authors:  Hendrik G Freling; Kees van Wijk; Karolien Jaspers; Petronella G Pieper; Karin M Vermeulen; Jeroen M van Swieten; Tineke P Willems
Journal:  Int J Cardiovasc Imaging       Date:  2012-09-04       Impact factor: 2.357

6.  Correlation of trabeculae and papillary muscles with clinical and cardiac characteristics and impact on CMR measures of LV anatomy and function.

Authors:  Michael L Chuang; Philimon Gona; Gilion L T F Hautvast; Carol J Salton; Susan J Blease; Susan B Yeon; Marcel Breeuwer; Christopher J O'Donnell; Warren J Manning
Journal:  JACC Cardiovasc Imaging       Date:  2012-11

7.  Semi-automatic measurement of left ventricular function on dual source computed tomography using five different software tools in comparison with magnetic resonance imaging.

Authors:  G J de Jonge; P A van der Vleuten; J Overbosch; D D Lubbers; M C Jansen-van der Weide; F Zijlstra; P M A van Ooijen; M Oudkerk
Journal:  Eur J Radiol       Date:  2010-11-26       Impact factor: 3.528

8.  Xenon ventilation CT using dual-source and dual-energy technique in children with bronchiolitis obliterans: correlation of xenon and CT density values with pulmonary function test results.

Authors:  Hyun Woo Goo; Dong Hyun Yang; Soo-Jong Hong; Jinho Yu; Byoung-Ju Kim; Joon Beom Seo; Eun Jin Chae; Jeongjin Lee; Bernhard Krauss
Journal:  Pediatr Radiol       Date:  2010-04-22

9.  Coronary CT angiography: automatic cardiac-phase selection for image reconstruction.

Authors:  Balazs Ruzsics; Mulugeta Gebregziabher; Heon Lee; Robin L Brothers; Thomas Allmendinger; Sebastian Vogt; Philip Costello; U Joseph Schoepf
Journal:  Eur Radiol       Date:  2009-03-11       Impact factor: 5.315

10.  Comparison of MRI, 64-slice MDCT and DSCT in assessing functional cardiac parameters of a moving heart phantom.

Authors:  J M Groen; P A van der Vleuten; M J W Greuter; F Zijlstra; M Oudkerk
Journal:  Eur Radiol       Date:  2008-10-25       Impact factor: 5.315

View more
  19 in total

1.  Asian consortium on radiation dose of pediatric cardiac CT (ASCI-REDCARD).

Authors:  Peter K T Hui; Hyun Woo Goo; Jing Du; Janice J K Ip; Suzu Kanzaki; Young Jin Kim; Supika Kritsaneepaiboon; Oktavia Lilyasari; Suvipaporn Siripornpitak
Journal:  Pediatr Radiol       Date:  2017-04-24

2.  Myocardial delayed-enhancement CT: initial experience in children and young adults.

Authors:  Hyun Woo Goo
Journal:  Pediatr Radiol       Date:  2017-05-23

3.  Technical feasibility of semiautomatic three-dimensional threshold-based cardiac computed tomography quantification of left ventricular mass.

Authors:  Hyun Woo Goo
Journal:  Pediatr Radiol       Date:  2018-11-23

4.  Computed tomography pulmonary vascular volume ratio in children and young adults with congenital heart disease: the effect of cardiac phase.

Authors:  Hyun Woo Goo
Journal:  Pediatr Radiol       Date:  2018-03-23

5.  Serial changes in anatomy and ventricular function on dual-source cardiac computed tomography after the Norwood procedure for hypoplastic left heart syndrome.

Authors:  Hyun Woo Goo
Journal:  Pediatr Radiol       Date:  2017-09-06

6.  Pulmonary vascular volume ratio measured by cardiac computed tomography in children and young adults with congenital heart disease: comparison with lung perfusion scintigraphy.

Authors:  Hyun Woo Goo; Sang Hyub Park
Journal:  Pediatr Radiol       Date:  2017-06-23

7.  Cardiac Computed Tomography-Derived Left Atrial Strain and Volume in Pediatric Patients With Congenital Heart Disease: A Comparative Analysis With Transthoracic Echocardiography.

Authors:  Wei-Hui Xie; Li-Jun Chen; Li-Wei Hu; Rong-Zhen Ouyang; Chen Guo; Ai-Min Sun; Qian Wang; Hai-Sheng Qiu; Yu-Qi Zhang; Hao Zhang; Qi-Hua Fu; Yu-Min Zhong
Journal:  Front Cardiovasc Med       Date:  2022-06-20

8.  Combined prospectively electrocardiography- and respiratory-triggered sequential cardiac computed tomography in free-breathing children: success rate and image quality.

Authors:  Hyun Woo Goo
Journal:  Pediatr Radiol       Date:  2018-03-27

9.  Comparison of Chest Pain Protocols for Electrocardiography-Gated Dual-Source Cardiothoracic CT in Children and Adults: The Effect of Tube Current Saturation on Radiation Dose Reduction.

Authors:  Hyun Woo Goo
Journal:  Korean J Radiol       Date:  2018-01-02       Impact factor: 3.500

10.  Optimal Attenuation Threshold for Quantifying CT Pulmonary Vascular Volume Ratio.

Authors:  Hyun Woo Goo; Sang Hyub Park
Journal:  Korean J Radiol       Date:  2020-06       Impact factor: 3.500

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.