Literature DB >> 26318787

Immobilization of aptamer-modified gold nanoparticles on BiOCl nanosheets: Tunable peroxidase-like activity by protein recognition.

Chia-Lun Hsu1, Chia-Wen Lien1, Chia-Wei Wang1, Scott G Harroun1, Chih-Ching Huang2, Huan-Tsung Chang3.   

Abstract

A self-assembled nanocomposite is prepared from an aqueous mixture of aptamer-modified gold nanoparticles (Apt-Au NPs), bismuth ions and chloride ions. The Apt-Au NPs are immobilized on bismuth oxychloride (BiOCl) nanosheets in situ to form Apt-Au NPs/BiOCl nanocomposites. The as-prepared nanocomposites exhibit high peroxidase-like activity for the catalytic conversion of Amplex Red (AR) to fluorescent resorufin in the presence of H2O2. The catalytic activity of Apt-Au NPs/BiOCl nanocomposites is at least 90-fold higher than that of Apt-Au NPs or BiOCl nanosheets, revealing synergistic effects on their activity. The catalytic activity of Apt-Au NPs/BiOCl nanocomposites is suppressed by vascular endothelial growth factor-A165 (VEGF-A165) molecules that specifically interact with the aptamer units (Del-5-1 and v7t-1) on the nanocomposite surface. The AR/H2O2-Apt-Au NPs/BiOCl nanocomposites probe shows high selectivity (>1000-fold over other proteins) and sensitivity (detection limit ~0.5nM) for the detection of VEGF-A165. Furthermore, the probe is employed for the detection of VEGF isoforms and for the study of interactions between VEGF and VEGF receptors. The practicality of this simple, rapid, cost-effective probe is validated by the analysis of VEGF-A165 in cell culture media, showing its great potential for the analysis of VEGF in biological samples.
Copyright © 2015 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Aptamers; Enzyme; Nanoparticles; Self-assembly; Synergistic effects

Mesh:

Substances:

Year:  2015        PMID: 26318787     DOI: 10.1016/j.bios.2015.08.049

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  3 in total

1.  [A colorimetric method for vascular endothelial growth factor detection based on aptamer and magnetic beads].

Authors:  Jing-Rong Liu; Yun-Ling Pan; Yan-Ping Zhao; Mei-Cen Liu; Jing-Hua Chen; Chun-Yan Li
Journal:  Nan Fang Yi Ke Da Xue Xue Bao       Date:  2016-02-20

Review 2.  Carbon dots as artificial peroxidases for analytical applications.

Authors:  Shih-Chun Wei; Yang-Wei Lin; Huan-Tsung Chang
Journal:  J Food Drug Anal       Date:  2020-12-15       Impact factor: 6.157

3.  Enhanced sensitivity of VEGF detection using catalase-mediated chemiluminescence immunoassay based on CdTe QD/H2O2 system.

Authors:  Fahimeh Ghavamipour; Hossein Rahmani; Maryam Shanehsaz; Khosro Khajeh; Manouchehr Mirshahi; Reza H Sajedi
Journal:  J Nanobiotechnology       Date:  2020-06-17       Impact factor: 10.435

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.