Literature DB >> 26313264

Comparison of invasive and noninvasive blood pressure measurements in anaesthetized horses using the Surgivet V9203.

Eleanor A Drynan1, Mara Schier1, Anthea L Raisis1.   

Abstract

OBJECTIVES: To determine the bias and precision of noninvasive versus invasive blood pressure measurements obtained using the Surgivet V9203 in anaesthetized horses; to compare these with the current American College of Veterinary Internal Medicine Hypertension Consensus Panel (AHCP) and Veterinary Blood Pressure Society (VBPS) recommendations; and to investigate whether noninvasive blood pressure monitoring could be a clinically useful alternative to invasive blood pressure monitoring in anaesthetized horses. STUDY
DESIGN: Prospective clinical study in a university teaching hospital. ANIMALS: Forty-three horses with an average weight of 485 ± 90 kg and a mean age of 103.4 ± 57.6 months.
METHODS: Arterial blood pressure (BP) was measured noninvasively (NIBP) via a cuff placed over either the ventral coccygeal artery or the metacarpal artery, and invasively (IBP) via a catheter in either the facial artery or the metatarsal artery. A total of 143 paired readings were obtained. Comparison of measurements was carried out using the Bland-Altman method. Analysis was performed using all the data, and these data were subdivided according to the position of the horse and the magnitude of the pressure measurement. To determine the accuracy of the noninvasive measurements, the calculated precision and bias were compared with AHCP and VBPS guidelines.
RESULTS: For all categories, NIBP measurements were generally lower than IBP measurements. For pooled data, the bias and precision for systolic arterial pressure (SAP) were 6.8 and 11.9 mmHg; for mean arterial pressure (MAP) the values were 1.9 and 10.0 mmHg; and for diastolic arterial pressure (DAP) they were 5.7 and 10.8 mmHg. The bias and precision for MAP and DAP measurements were within the recommended guidelines defined by the AHCP and VBPS. CONCLUSIONS AND CLINICAL RELEVANCE: These results suggests that systolic, mean and diastolic NIBP measured using the Surgivet V9203 are a clinically acceptable alternative to IBP measurements in anaesthetized horses undergoing routine elective surgeries.
© 2015 Association of Veterinary Anaesthetists and the American College of Veterinary Anesthesia and Analgesia.

Entities:  

Keywords:  agreement; blood pressure; horse; hypotension; mean arterial pressure

Mesh:

Year:  2015        PMID: 26313264     DOI: 10.1111/vaa.12297

Source DB:  PubMed          Journal:  Vet Anaesth Analg        ISSN: 1467-2987            Impact factor:   1.648


  3 in total

1.  A Comparison of the Efficacy and Cardiopulmonary Effects of 3 Different Sedation Protocols in Otolemur garnettii.

Authors:  Kelsey R Finnie; Carissa P Jones; William D Dupont; Kenneth J Salleng; Katherine A Shuster
Journal:  J Am Assoc Lab Anim Sci       Date:  2020-07-21       Impact factor: 1.232

2.  Comparison of oscillometric, Doppler and invasive blood pressure measurement in anesthetized goats.

Authors:  Olga Szaluś-Jordanow; Michał Czopowicz; Agata Moroz; Marcin Mickiewicz; Magdalena Garncarz; Emilia Bagnicka; Tadeusz Frymus; Jarosław Kaba
Journal:  PLoS One       Date:  2018-05-23       Impact factor: 3.240

3.  Bias Associated with Peripheral Non-Invasive Compared to Invasive Arterial Blood Pressure Monitoring in Healthy Anaesthetised and Standing Horses Using the Bionet BM7Vet.

Authors:  Shaun Pratt; Tamsin S Barnes; Nicholas Cowling; Karla de Klerk; Joanne Rainger; Albert Sole-Guitart; Solomon Woldeyohannes; Wendy Goodwin
Journal:  Vet Sci       Date:  2022-01-28
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.