Literature DB >> 26313230

Fluoroscopic Views for a More Accurate Placement of Iliosacral Screws: An Experimental Study.

Ji Wan Kim1, Juan C Quispe, Jiandong Hao, Benoit Herbert, Mark Hake, Cyril Mauffrey.   

Abstract

OBJECTIVES: Misperception on the fluoroscopic image showing a well-placed iliosacral (IS) screw can occur, when the screw is in reality misplaced. The purpose of this study was to demonstrate and highlight examples of misperception and suggest alternative inlet and outlet views to confirm adequate IS screw placement.
METHODS: We used 9 different pelvic plastic models. In 8 of those models, IS screws were purposely misplaced: exiting anterior at the midportion of the S1 body, exiting at the lateral aspect of the anterior S1 body, abutting posterior to S1 body, exiting posterior to the S1 body, exiting superior to the far-side of the sacral ala, exiting superior to the S1 body, exiting partially in the S1 foramen, exiting completely in the S1 foramen. One model was used as control with correct screw placement. Different outlet and inlet views were tested to accurately detect important anatomic landmarks and avoid fake phenomenon (FP) using 3 different angles.
RESULTS: Misperception occurred in 3 models: (1) penetration at the midportion of the anterior border of S1, (2) penetration of the superior sacrum ala, and (3) partial penetration of S1 foramen. In the first situation, misperception could be avoided when the "anterior inlet view" was obtained. In the other 2 situations, misperception could be avoided using specific outlet views herein described.
CONCLUSIONS: Our findings highlight that misperception can occur using standard inlet and outlet views. We suggest using 2 variations of the inlet views and 3 variations of the outlet views to avoid misperception in clinical practice.

Mesh:

Year:  2016        PMID: 26313230     DOI: 10.1097/BOT.0000000000000426

Source DB:  PubMed          Journal:  J Orthop Trauma        ISSN: 0890-5339            Impact factor:   2.512


  3 in total

1.  Posterior pelvic ring bone density with implications for percutaneous screw fixation.

Authors:  Jonathan G Eastman; Trevor J Shelton; Milton Lee Chip Routt; Mark R Adams
Journal:  Eur J Orthop Surg Traumatol       Date:  2020-09-09

2.  Percutaneous posterior transiliac plate versus iliosacral screw fixation for posterior fixation of Tile C-type pelvic fractures: a retrospective comparative study.

Authors:  Chul-Ho Kim; Jung Jae Kim; Ji Wan Kim
Journal:  BMC Musculoskelet Disord       Date:  2022-06-16       Impact factor: 2.562

3.  A novel patient-specific three-dimensional-printed external template to guide iliosacral screw insertion: a retrospective study.

Authors:  Fan Yang; Sheng Yao; Kai-Fang Chen; Feng-Zhao Zhu; Ze-Kang Xiong; Yan-Hui Ji; Ting-Fang Sun; Xiao-Dong Guo
Journal:  BMC Musculoskelet Disord       Date:  2018-11-13       Impact factor: 2.362

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.