Literature DB >> 26309770

Clinical application of low-dose phase contrast breast CT: methods for the optimization of the reconstruction workflow.

S Pacilè1, F Brun1, C Dullin2, Y I Nesterest3, D Dreossi4, S Mohammadi5, M Tonutti6, F Stacul6, D Lockie7, F Zanconati8, A Accardo9, G Tromba4, T E Gureyev10.   

Abstract

Results are presented of a feasibility study of three-dimensional X-ray tomographic mammography utilising in-line phase contrast. Experiments were performed at SYRMEP beamline of Elettra synchrotron. A specially designed plastic phantom and a mastectomy sample containing a malignant lesion were used to study the reconstructed image quality as a function of different image processing operations. Detailed evaluation and optimization of image reconstruction workflows have been carried out using combinations of several advanced computed tomography algorithms with different pre-processing and post-processing steps. Special attention was paid to the effect of phase retrieval on the diagnostic value of the reconstructed images. A number of objective image quality indices have been applied for quantitative evaluation of the results, and these were compared with subjective assessments of the same images by three experienced radiologists and one pathologist. The outcomes of this study provide practical guidelines for the optimization of image processing workflows in synchrotron-based phase-contrast mammo-tomography.

Keywords:  (100.5070) Phase retrieval; (110.3000) Image quality assessment; (170.3010) Image reconstruction techniques; (170.3830) Mammography; (170.3880) Medical and biological imaging; (170.6960) Tomography; (170.7440) X-ray imaging; (340.6720) Synchrotron radiation

Year:  2015        PMID: 26309770      PMCID: PMC4541534          DOI: 10.1364/BOE.6.003099

Source DB:  PubMed          Journal:  Biomed Opt Express        ISSN: 2156-7085            Impact factor:   3.732


  27 in total

1.  Image quality assessment: from error visibility to structural similarity.

Authors:  Zhou Wang; Alan Conrad Bovik; Hamid Rahim Sheikh; Eero P Simoncelli
Journal:  IEEE Trans Image Process       Date:  2004-04       Impact factor: 10.856

2.  Cone-beam CT for breast imaging: Radiation dose, breast coverage, and image quality.

Authors:  Avice O'Connell; David L Conover; Yan Zhang; Posy Seifert; Wende Logan-Young; Chuen-Fu Linda Lin; Lawrence Sahler; Ruola Ning
Journal:  AJR Am J Roentgenol       Date:  2010-08       Impact factor: 3.959

3.  Contrast-enhanced dedicated breast CT: initial clinical experience.

Authors:  Nicolas D Prionas; Karen K Lindfors; Shonket Ray; Shih-Ying Huang; Laurel A Beckett; Wayne L Monsky; John M Boone
Journal:  Radiology       Date:  2010-09       Impact factor: 11.105

4.  Embedded foveation image coding.

Authors:  Z Wang; A C Bovik
Journal:  IEEE Trans Image Process       Date:  2001       Impact factor: 10.856

5.  Compensation of ring artefacts in synchrotron tomographic images.

Authors:  Mirko Boin; Astrid Haibel
Journal:  Opt Express       Date:  2006-12-11       Impact factor: 3.894

6.  Benefit of screening mammography in women aged 40-49: a new meta-analysis of randomized controlled trials.

Authors:  R E Hendrick; R A Smith; J H Rutledge; C R Smart
Journal:  J Natl Cancer Inst Monogr       Date:  1997

7.  Algebraic reconstruction techniques (ART) for three-dimensional electron microscopy and x-ray photography.

Authors:  R Gordon; R Bender; G T Herman
Journal:  J Theor Biol       Date:  1970-12       Impact factor: 2.691

8.  Cone beam breast CT with multiplanar and three dimensional visualization in differentiating breast masses compared with mammography.

Authors:  Binghui Zhao; Xiaohua Zhang; Weixing Cai; David Conover; Ruola Ning
Journal:  Eur J Radiol       Date:  2014-07-15       Impact factor: 3.528

9.  The mammography project at the SYRMEP beamline.

Authors:  D Dreossi; A Abrami; F Arfelli; P Bregant; K Casarin; V Chenda; M A Cova; R Longo; R-H Menk; E Quai; E Quaia; L Rigon; T Rokvic; D Sanabor; M Tonutti; G Tromba; A Vascotto; F Zanconati; E Castelli
Journal:  Eur J Radiol       Date:  2008-07-09       Impact factor: 3.528

10.  Visualizing typical features of breast fibroadenomas using phase-contrast CT: an ex-vivo study.

Authors:  Susanne Grandl; Marian Willner; Julia Herzen; Anikó Sztrókay-Gaul; Doris Mayr; Sigrid D Auweter; Alexander Hipp; Lorenz Birnbacher; Mathias Marschner; Michael Chabior; Maximilian Reiser; Franz Pfeiffer; Fabian Bamberg; Karin Hellerhoff
Journal:  PLoS One       Date:  2014-05-13       Impact factor: 3.240

View more
  7 in total

1.  Dose and diagnostic performance comparison between phase-contrast mammography with synchrotron radiation and digital mammography: a clinical study report.

Authors:  Christian Fedon; Luigi Rigon; Fulvia Arfelli; Diego Dreossi; Elisa Quai; Maura Tonutti; Giuliana Tromba; Maria Assunta Cova; Renata Longo
Journal:  J Med Imaging (Bellingham)       Date:  2018-02-01

2.  Comparison of propagation-based CT using synchrotron radiation and conventional cone-beam CT for breast imaging.

Authors:  Seyedamir Tavakoli Taba; Patrycja Baran; Yakov I Nesterets; Serena Pacile; Susanne Wienbeck; Christian Dullin; Konstantin Pavlov; Anton Maksimenko; Darren Lockie; Sheridan C Mayo; Harry M Quiney; Diego Dreossi; Fulvia Arfelli; Giuliana Tromba; Sarah Lewis; Timur E Gureyev; Patrick C Brennan
Journal:  Eur Radiol       Date:  2020-01-23       Impact factor: 5.315

Review 3.  Review of quantitative multiscale imaging of breast cancer.

Authors:  Michael A Pinkert; Lonie R Salkowski; Patricia J Keely; Timothy J Hall; Walter F Block; Kevin W Eliceiri
Journal:  J Med Imaging (Bellingham)       Date:  2018-01-22

4.  SYRMEP Tomo Project: a graphical user interface for customizing CT reconstruction workflows.

Authors:  Francesco Brun; Lorenzo Massimi; Michela Fratini; Diego Dreossi; Fulvio Billé; Agostino Accardo; Roberto Pugliese; Alessia Cedola
Journal:  Adv Struct Chem Imaging       Date:  2017-01-19

5.  Advanced 3D Imaging of Uterine Leiomyoma's Morphology by Propagation-based Phase-Contrast Microtomography.

Authors:  Alessandra Giuliani; Stefania Greco; Serena Pacilè; Alessandro Zannotti; Giovanni Delli Carpini; Giuliana Tromba; Stefano Raffaele Giannubilo; Andrea Ciavattini; Pasquapina Ciarmela
Journal:  Sci Rep       Date:  2019-07-22       Impact factor: 4.379

6.  Free propagation phase-contrast breast CT provides higher image quality than cone-beam breast-CT at low radiation doses: a feasibility study on human mastectomies.

Authors:  S Pacilè; C Dullin; P Baran; M Tonutti; C Perske; U Fischer; J Albers; F Arfelli; D Dreossi; K Pavlov; A Maksimenko; S C Mayo; Y I Nesterets; S Tavakoli Taba; S Lewis; P C Brennan; T E Gureyev; G Tromba; S Wienbeck
Journal:  Sci Rep       Date:  2019-09-24       Impact factor: 4.379

7.  Motion artifacts assessment and correction using optical tracking in synchrotron radiation breast CT.

Authors:  Luca Brombal; Lucia Mariel Arana Peña; Fulvia Arfelli; Renata Longo; Francesco Brun; Adriano Contillo; Francesca Di Lillo; Giuliana Tromba; Vittorio Di Trapani; Sandro Donato; Ralf Hendrik Menk; Luigi Rigon
Journal:  Med Phys       Date:  2021-07-29       Impact factor: 4.506

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.