Literature DB >> 26286004

Patient dose evaluation for the whole-body low-dose multidetector CT (WBLDMDCT) skeleton study in multiple myeloma (MM).

Fabiola Cretti1, Giovanna Perugini2.   

Abstract

OBJECTIVE: This study aimed at estimating the patient effective dose during whole-body low-dose multi detector computed tomography with a scanner Philips Brillance 64, and to compare it with those reported in literature for the same procedure and with the dose of the conventional X-ray examination in our institution.
MATERIALS AND METHODS: WBLDMDCT effective dose was evaluated for 29 MM patients, using Dose Length Product values. Conventional X-ray examination dose was estimated using a Rando Phantom and Dose Area Product indexes. ICRP Publication 103 based coefficients were used.
RESULTS: Mean WBLDMDCT effective dose values-estimated using sex-specific conversion coefficients and body weight factors-were 3.6 and 2.8 mSv for females and males, respectively. The effective dose for the conventional method was 1.2 mSv for Rando phantom.
CONCLUSION: The WBLDMDCT effective dose in our institution is consistent with the values reported in previous studies. Such a dose is about 2.5- to 3-fold higher than the mean radiation dose of the conventional X-ray study. Nevertheless, considering the improved diagnostic accuracy of the CT investigation, the comfort of the patient and the old age of the MM population, dose/quality ratio can be considered favourable.

Entities:  

Keywords:  Computed tomography patient dose; Multiple myeloma (MM); Skeleton X-ray conventional examination; Whole-body low-dose multidetector CT (WBLDMDCT)

Mesh:

Year:  2015        PMID: 26286004     DOI: 10.1007/s11547-015-0573-6

Source DB:  PubMed          Journal:  Radiol Med        ISSN: 0033-8362            Impact factor:   3.469


  26 in total

Review 1.  Hematopoietic tumors and metastases involving bone.

Authors:  Sung H Kim; Stacy E Smith; Michael E Mulligan
Journal:  Radiol Clin North Am       Date:  2011-11       Impact factor: 2.303

Review 2.  Iterative reconstruction methods in X-ray CT.

Authors:  Marcel Beister; Daniel Kolditz; Willi A Kalender
Journal:  Phys Med       Date:  2012-02-10       Impact factor: 2.685

3.  The 2007 Recommendations of the International Commission on Radiological Protection. ICRP publication 103.

Authors: 
Journal:  Ann ICRP       Date:  2007

Review 4.  Conversion coefficients for use in radiological protection against external radiation. Adopted by the ICRP and ICRU in September 1995.

Authors: 
Journal:  Ann ICRP       Date:  1996

5.  Whole-body low-dose multidetector row-CT in the diagnosis of multiple myeloma: an alternative to conventional radiography.

Authors:  Marius Horger; Claus D Claussen; Ulrike Bross-Bach; Reinhard Vonthein; Tobias Trabold; Martin Heuschmid; Christina Pfannenberg
Journal:  Eur J Radiol       Date:  2005-05       Impact factor: 3.528

Review 6.  Imaging in multiple myeloma.

Authors:  Stefan Delorme; Andrea Baur-Melnyk
Journal:  Eur J Radiol       Date:  2009-03-09       Impact factor: 3.528

7.  Hyperattenuating bone marrow abnormalities in myeloma patients using whole-body non-enhanced low-dose MDCT: correlation with haematological parameters.

Authors:  M Horger; P Pereira; C D Claussen; L Kanz; R Vonthein; B Denecke; C Driessen
Journal:  Br J Radiol       Date:  2008-05       Impact factor: 3.039

8.  Managing patient dose in multi-detector computed tomography(MDCT). ICRP Publication 102.

Authors:  J Valentin
Journal:  Ann ICRP       Date:  2007

9.  Radiation risks potentially associated with low-dose CT screening of adult smokers for lung cancer.

Authors:  David J Brenner
Journal:  Radiology       Date:  2004-05       Impact factor: 11.105

10.  Accuracy of whole-body low-dose multidetector CT (WBLDCT) versus skeletal survey in the detection of myelomatous lesions, and correlation of disease distribution with whole-body MRI (WBMRI).

Authors:  T G Gleeson; J Moriarty; C P Shortt; J P Gleeson; P Fitzpatrick; B Byrne; J McHugh; M O'Connell; P O'Gorman; S J Eustace
Journal:  Skeletal Radiol       Date:  2008-11-14       Impact factor: 2.199

View more
  2 in total

1.  Whole Body Low Dose Computed Tomography Using Third-Generation Dual-Source Multidetector With Spectral Shaping: Protocol Optimization and Literature Review.

Authors:  Dario Baldi; Liberatore Tramontano; Vincenzo Alfano; Bruna Punzo; Carlo Cavaliere; Marco Salvatore
Journal:  Dose Response       Date:  2020-12-29       Impact factor: 2.658

2.  Whole Body Low Dose Computed Tomography (WBLDCT) Can Be Comparable to Whole-Body Magnetic Resonance Imaging (WBMRI) in the Assessment of Multiple Myeloma.

Authors:  Davide Ippolito; Teresa Giandola; Cesare Maino; Davide Gandola; Maria Ragusi; Pietro Andrea Bonaffini; Sandro Sironi
Journal:  Diagnostics (Basel)       Date:  2021-05-11
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.