Literature DB >> 2628367

Reliability and validity of the Omnitron hydraulic resistance exercise and testing device.

P P Lagassé1, F I Katch, V L Katch, M A Roy.   

Abstract

This study assessed the measurement reliability and validity of the Hydra-Fitness Omnitron, a microprocessor-controlled isokinetic ergometer that provides concentric resistance for dynamic extension and flexion movements as well as resistance for isometric contractions. Maximal peak torque output measured by the Omnitron and strain gauge devices connected to the apparatus were compared in 26 physically active males who were tested over 3 days for isometric knee extension and isokinetic knee flexion/extension at two resistance levels. Maximal torque outputs remained stable on days 2 and 3 (p less than 0.05), and intraclass reliability yielded r = 0.94 to 0.98. There was no difference between the slopes of the regression lines for the different experimental conditions (p less than 0.05). There was significant improvement between day 1 and days 2 and 3 that corresponded to a combination of a training and learning effect. Thus, one practice session was necessary to obtain reliable individual differences. The validity correlations between peak torque output measured from the Omnitron and strain gauges were greater than r = 0.94. There was a small discrepancy (0.44 to 0.88 Nm) between the two measuring devices that can be explained by the difference in shank pad positioning that accommodates for different segment lengths. We conclude that reliability and validity were excellent over a wide range of torque outputs measured during maximal isometric and maximal dynamic double concentric flexion and extension movements.

Entities:  

Mesh:

Year:  1989        PMID: 2628367     DOI: 10.1055/s-2007-1024943

Source DB:  PubMed          Journal:  Int J Sports Med        ISSN: 0172-4622            Impact factor:   3.118


  4 in total

1.  A new approach to rowing ergometry: establishing exercise intensity relative to maximum force output.

Authors:  R L Jensen; F I Katch
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1991

Review 2.  Physiological adaptations to velocity-controlled resistance training.

Authors:  G J Bell; H A Wenger
Journal:  Sports Med       Date:  1992-04       Impact factor: 11.136

3.  Electrical stimulation-induced changes in performance and fiber type proportion of human knee extensor muscles.

Authors:  R Thériault; M R Boulay; G Thériault; J A Simoneau
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1996

4.  Effectiveness of a Home-Based Eccentric-Exercise Program on the Torque-Angle Relationship of the Shoulder External Rotators: A Pilot Study.

Authors:  Timothy L Uhl; Thomas Rice; Brianna Papotto; Timothy A Butterfield
Journal:  J Sport Rehabil       Date:  2017-04       Impact factor: 1.931

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.