Literature DB >> 26280956

Efficacy of hip resurfacing arthroplasty: 6 year results from an international multisurgeon prospective cohort study.

Tajeshwar S Aulakh, Narlaka Jayasekera, Rohit Singh, Amit Patel, Nick Roulahamin, Jan H Kuiper, James B Richardson.   

Abstract

Metal-on-metal hip resurfacing is undertaken worldwide. This procedure helps preserve femoral bone stock and allows patients to return to high activity sports. Most outcome studies are individual surgeon case series from single centers where the results and outcomes are evaluated by the same surgeon. One method of increasing the external validity of a follow-up study is to have a multi-centre study design with independent assessment of the outcomes. We present an independent assessment of eleven year follow-up of hip resurfacing outcomes from an international hip resurfacing register. The purpose of this study was to assess: Implant survival at maximum follow-up for revision due to any reason, implant survival at maximum follow-up for revision due to major causes of failure, hip function following hip resurfacing and factors affecting hip function, effect of gender and age on hip function and implant survival, effect of femoral component size on hip function and implant survival. 4535 patients (5000 hips) entered into the registry during 1997-2002 were studied. In summary, at a maximum follow-up of 11 years hip resurfacing has a good implant survival of 96.2% and excellent post-operative function. This is excellent given the international and multisurgeon nature of this cohort where majority of the surgeons were in their learning curve.

Entities:  

Mesh:

Year:  2015        PMID: 26280956

Source DB:  PubMed          Journal:  Acta Orthop Belg        ISSN: 0001-6462            Impact factor:   0.500


  3 in total

Review 1.  Hip replacement in femoral head osteonecrosis: current concepts.

Authors:  Michelangelo Scaglione; Luca Fabbri; Fabio Celli; Francesco Casella; Giulio Guido
Journal:  Clin Cases Miner Bone Metab       Date:  2016-04-07

2.  Current indications for hip resurfacing arthroplasty in 2016.

Authors:  Robert Sershon; Rishi Balkissoon; Craig J Della Valle
Journal:  Curr Rev Musculoskelet Med       Date:  2016-03

3.  Biomimetic Multispiked Connecting Ti-Alloy Scaffold Prototype for Entirely-Cementless Resurfacing Arthroplasty Endoprostheses-Exemplary Results of Implantation of the Ca-P Surface-Modified Scaffold Prototypes in Animal Model and Osteoblast Culture Evaluation.

Authors:  Ryszard Uklejewski; Piotr Rogala; Mariusz Winiecki; Renata Tokłowicz; Piotr Ruszkowski; Maria Wołuń-Cholewa
Journal:  Materials (Basel)       Date:  2016-06-29       Impact factor: 3.623

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.