Clinical Outcomes After Implantation of a Trifocal Toric Intraocular Lens.

Florian T A Kretz, Detlev Breyer, Karsten Klabe, Phillipp Hagen, Hakan Kaymak, Michael J Koss, Matthias Gerl, Matthias Mueller, Ralf H Gerl, Gerd U Auffarth.   

Abstract

PURPOSE: To evaluate the visual, refractive, and contrast sensitivity outcomes, as well as the level of photic phenomena, after cataract surgery with implantation of a trifocal diffractive toric intraocular lens (IOL).
METHODS: This prospective study included 56 eyes with corneal astigmatism of 1.00 diopters (D) or greater of 28 patients (age: 23 to 78 years) undergoing cataract surgery with implantation of the trifocal toric IOL AT LISA tri toric 939MP (Carl Zeiss Meditec, Jena, Germany). Monocular and binocular visual outcomes, refractive changes, contrast sensitivity, and photic phenomena perception (Halo & Glare Simulator; Eyeland-Design Network GmbH, Vreden, Germany) were evaluated at 3 months postoperatively.
RESULTS: Mean 3-month postoperative monocular uncorrected distance (UDVA), intermediate (UIVA), and near (UNVA) visual acuities were 0.13±0.15, 0.08±0.15, and 0.13±0.18 logMAR, respectively. Binocular postoperative CDVA, DCIVA, and DCNVA values were 0.10 logMAR or better in all cases. A total of 88.2%, 88.2%, and 95.5% of eyes achieved binocular UDVA, UIVA, and UNVA values of 0.20 logMAR or better, respectively. Postoperative refractive cylinder was 0.50 D or less and 1.00 D or less in 78.6% and 98.2% of eyes, respectively. Photopic contrast sensitivity was significantly better than mesopic values for the spatial frequencies of 6 (P=.007), 12 (P=.005), and 18 cycles/degree (P=.011). Mean size and intensity of halos were 50.67±15.69 and 54.89±17.86, respectively. Mean glare size and intensity were 39.67±3.51 and 44.67±15.01, respectively.
CONCLUSIONS: The evaluated trifocal diffractive toric IOL provides an effective restoration of the distance, intermediate, and near vision after cataract surgery with good levels of visual quality and minimal photic phenomena. Copyright 2015, SLACK Incorporated.

Entities:  

Mesh:

Year:  2015        PMID: 26274516     DOI: 10.3928/1081597X-20150622-01

Source DB:  PubMed          Journal:  J Refract Surg        ISSN: 1081-597X            Impact factor:   3.573


  12 in total

1.  [Optical quality of three trifocal intraocular lens models : An optical bench comparison].

Authors:  R Khoramnia; T M Yildirim; T Tandogan; S Liebing; G Łabuz; C Y Choi; G Auffarth
Journal:  Ophthalmologe       Date:  2018-01       Impact factor: 1.059

2.  Comparison of trifocal toric and bifocal toric intraocular lens implantation in patients with cataract and high corneal astigmatism.

Authors:  Merve Bozkurt Gencer; Hikmet Basmak; Erdogan Yasar; Ozkan Onal
Journal:  Int J Ophthalmol       Date:  2021-12-18       Impact factor: 1.779

3.  Visual performance, reading ability and patient satisfaction after implantation of a diffractive trifocal intraocular lens.

Authors:  Rita Mencucci; Eleonora Favuzza; Orsola Caporossi; Stanislao Rizzo
Journal:  Clin Ophthalmol       Date:  2017-11-13

4.  Visual and refractive outcomes following implantation of a new trifocal intraocular lens.

Authors:  Michael Lawless; Chris Hodge; Joe Reich; Lewis Levitz; Uday K Bhatt; Colm McAlinden; Kate Roberts; Timothy V Roberts
Journal:  Eye Vis (Lond)       Date:  2017-04-04

5.  Influence of the level of monovision on visual outcome with an extended range of vision intraocular lens.

Authors:  Béatrice Cochener
Journal:  Clin Ophthalmol       Date:  2018-11-12

Review 6.  Current Trends in Modern Visual Intraocular Lens Enhancement Surgery in Stable Keratoconus: A Synopsis of Do's, Don'ts and Pitfalls.

Authors:  Iraklis Vastardis; Despoina Sagri; Sofia Fili; Peter Wölfelschneider; Markus Kohlhaas
Journal:  Ophthalmol Ther       Date:  2019-10-11

7.  Visual outcomes and patient satisfaction after bilateral implantation of a new trifocal diffractive intraocular lens.

Authors:  Abdulmohsen K Almulhim; Khalid M Alarfaj; Abdulaziz A Altaisan; Arwa Z Alromaih; Razan A Aldawod
Journal:  Saudi J Ophthalmol       Date:  2018-09-17

8.  Rotational stability and visual performance 3 months after bilateral implantation of a new toric extended range of vision intraocular lens.

Authors:  Kjell Gunnar Gundersen
Journal:  Clin Ophthalmol       Date:  2018-07-18

9.  Comparison of clinical performance between trifocal and bifocal intraocular lenses: A meta-analysis.

Authors:  Zequan Xu; Danmin Cao; Xu Chen; Song Wu; Xin Wang; Qiang Wu
Journal:  PLoS One       Date:  2017-10-26       Impact factor: 3.240

10.  Multicenter Evaluation of Time, Operational, and Economic Efficiencies of a New Preloaded Intraocular Lens Delivery System versus Manual Intraocular Lens Delivery.

Authors:  Javier Mendicute; Lucia Bascarán; Luis Pablo; Cédric Schweitzer; Laurent Velasque; Christine Bouchet; Aldo A Martinez
Journal:  Clin Ophthalmol       Date:  2021-02-16
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.