Literature DB >> 26273750

Xenon Anesthesia: A Systematic Review and Meta-Analysis of Randomized Controlled Trials.

Lawrence Siu-Chun Law1, Elaine Ah-Gi Lo, Tong Joo Gan.   

Abstract

BACKGROUND: Xenon anesthesia has been studied for decades. However, no meta-analysis of randomized controlled trials (RCTs) on xenon anesthesia has been conducted. The aim of this study was to systematically review all available evidence from RCTs comparing xenon and other inhaled and IV anesthetics on anesthetic outcomes. Our meta-analysis attempted to quantify the effects of xenon anesthesia on clinical outcomes in relation to other anesthetics.
METHODS: We found 43 RCTs from PubMed, MEDLINE, CENTRAL, EMBASE, and CINAHL (until January 2015). A total of 31 studies comparing xenon (841 patients) with other inhaled agents (836 patients) and 12 studies comparing xenon (373 patients) with propofol (360 patients) were found. We evaluated clinical outcomes, such as intraoperative hemodynamics, emergence, and postoperative nausea and vomiting (PONV).
RESULTS: Patients undergoing xenon anesthesia had a lower heart rate and higher mean arterial pressure (MAP) intraoperatively than those receiving volatile anesthesia (mean difference = -6 min⁻¹ [99% confidence interval {99% CI} -10.0 to -2.3]; mean difference = 9 mm Hg [99% CI 3.1-14.4]) and propofol anesthesia (mean difference = -10 min⁻¹ [99% CI -12.4 to -6.6]; mean difference = 7 mm Hg [99% CI 0.85-13.2]). Compared with baseline, intraoperative MAP remained relatively stable (change < 5.5%, 99% CI within ±20% of the baseline) under xenon anesthesia, but MAP decreased by ≥15% under volatile (mean difference = -17 mm Hg [99% CI -29.5 to - 4.9], percentage change = -17.5%) and propofol (mean difference = -14 mm Hg [99% CI -26.1 to -2.5], percentage change = -15.0%) anesthesia. Patients had faster emergence from xenon than from volatile anesthesia: eyes opening (versus all volatile agents: mean 4 vs 7 minutes, percentage change = -49.8% [99% CI -55.1% to -44.0%]), tracheal extubation (versus all volatile agents: mean 4 vs 8 minutes percentage change = -44.6% [99% CI -57.3% to -28.1%]), orientation (versus sevoflurane: mean 5 vs 10 minutes, percentage change = -45.1% [99% CI -58.5% to -28.1%]), countdown (versus sevoflurane: mean 6 vs 10 minutes, percentage change = -41.7% [99% CI -50.3% to -31.6%]; versus isoflurane: mean 6 vs 14 minutes, percentage change = -57.7% [99% CI -65.7% to -48.3%]), and reaction on demand (versus sevoflurane: mean 4 vs 8 minutes, percentage change = -53.2% [99% CI -65.7% to -35.6%]). However, xenon anesthesia increased the risks of PONV (incidence 34.4% vs 19.9%; risk ratio = 1.72 [99% CI 1.10-2.69], risk difference = 0.19 [99% CI 0.04-0.33]).
CONCLUSIONS: Xenon anesthesia provides relatively more stable intraoperative blood pressure, lower heart rate, and faster emergence from anesthesia than volatile and propofol anesthesia. However, xenon is associated with a higher incidence of PONV.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 26273750     DOI: 10.1213/ANE.0000000000000914

Source DB:  PubMed          Journal:  Anesth Analg        ISSN: 0003-2999            Impact factor:   5.108


  17 in total

Review 1.  Perioperative neurocognitive disorders: A narrative review focusing on diagnosis, prevention, and treatment.

Authors:  Hao Kong; Long-Ming Xu; Dong-Xin Wang
Journal:  CNS Neurosci Ther       Date:  2022-06-01       Impact factor: 7.035

2.  Xenon Anesthesia and CT: Noninvasive Measures of Brain Anesthetic Concentration.

Authors:  Andrew McKinstry-Wu; Charles W Carspecken; Alex Proekt; Max B Kelz
Journal:  Methods Enzymol       Date:  2018-03-03       Impact factor: 1.600

Review 3.  Neuroprotective Properties of Xenon.

Authors:  Mervyn Maze; Timo Laitio
Journal:  Mol Neurobiol       Date:  2019-11-22       Impact factor: 5.590

4.  Pulmonary static inflation with 50% xenon attenuates decline in tissue factor in patients undergoing Stanford type A acute aortic dissection repair.

Authors:  Xudong Pan; Jiakai Lu; Weiping Cheng; Yanwei Yang; Junming Zhu; Mu Jin
Journal:  J Thorac Dis       Date:  2018-07       Impact factor: 2.895

5.  [Inhalational anesthetics].

Authors:  Jan Jedlicka; Philipp Groene; Julia Linhart; Elisabeth Raith; Da Vy Mu Stapha; Peter Conzen
Journal:  Anaesthesist       Date:  2021-04       Impact factor: 1.041

6.  Protection of xenon against postoperative oxygen impairment in adults undergoing Stanford Type-A acute aortic dissection surgery: Study protocol for a prospective, randomized controlled clinical trial.

Authors:  Mu Jin; Yi Cheng; Yanwei Yang; Xudong Pan; Jiakai Lu; Weiping Cheng
Journal:  Medicine (Baltimore)       Date:  2017-08       Impact factor: 1.889

7.  Renal function following xenon anesthesia for partial nephrectomy-An explorative analysis of a randomized controlled study.

Authors:  Ana Stevanovic; Patrick Schaefer; Mark Coburn; Rolf Rossaint; Christian Stoppe; Peter Boor; David Pfister; Axel Heidenreich; Hildegard Christ; Martin Hellmich; Astrid V Fahlenkamp
Journal:  PLoS One       Date:  2017-07-18       Impact factor: 3.240

8.  Effects of pulmonary static inflation with 50% xenon on oxygen impairment during cardiopulmonary bypass for stanford type A acute aortic dissection: A pilot study.

Authors:  Mu Jin; Yanwei Yang; Xudong Pan; Jiakai Lu; Zhiquan Zhang; Weiping Cheng
Journal:  Medicine (Baltimore)       Date:  2017-03       Impact factor: 1.889

9.  Argon does not affect cerebral circulation or metabolism in male humans.

Authors:  Frank Grüne; Stephan Kazmaier; Sanne Elisabeth Hoeks; Robert Jan Stolker; Marc Coburn; Andreas Weyland
Journal:  PLoS One       Date:  2017-02-16       Impact factor: 3.240

10.  Anaesthesia for open wrist fracture surgery in adults/elderly.

Authors:  Irene Sellbrandt; Metha Brattwall; Margareta Warrén Stomberg; Pether Jildenstål; Jan G Jakobsson
Journal:  F1000Res       Date:  2017-11-13
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.