P Machi1, V Costalat2, K Lobotesis3, C Ruiz2, Y B Cheikh2, O Eker2, G Gascou2, F Danière2, C Riquelme2, A Bonafé2. 1. From the Centre Hospitalier Universitaire Gui de Chauliac (P.M., V.C., C.R., Y.B.C., O.E., G.G., F.D., C.R., A.B.), Montpellier, France paolo.machi@gmail.com. 2. From the Centre Hospitalier Universitaire Gui de Chauliac (P.M., V.C., C.R., Y.B.C., O.E., G.G., F.D., C.R., A.B.), Montpellier, France. 3. Imperial College Healthcare (K.L.), London, UK.
Abstract
BACKGROUND AND PURPOSE: We report our preliminary results in terms of safety and efficacy in using the low-profile LEO Baby stent for the treatment of large-neck and complex intracranial aneurysms with balloon-then-stent-assisted coiling and single- or dual-stent-assisted coiling. MATERIALS AND METHODS: Clinical and radiologic data of all consecutive patients treated at our institution from September 2012 to October 2013 for an intracranial aneurysm by using a LEO Baby stent were retrospectively analyzed. Immediate and midterm clinical and anatomic follow-up of each patient is reported. RESULTS: Twenty-nine patients with 29 aneurysms were treated with LEO Baby stents at our institution. The mean age of patients was 48 years; 20 patients were women (71%). One patient was treated in the acute phase of a subarachnoid hemorrhage. In 8 procedures, a double-lumen-catheter balloon was used for balloon-then-stent-assisted coiling. In 3 cases, a LEO Baby stent was used in a Y-, T-, and telescopic dual-stent configuration. In 18 cases, a single LEO Baby stent was used. In 2 cases, technical failure to deploy the stent resulted in acute parent artery thrombosis. In 3 further cases, thromboembolic complications occurred intraoperatively. MR imaging and angiographic midterm follow-up showed complete aneurysm occlusion for 96% of the followed patients (27/29). Clinical outcome was favorable for all patients followed up. CONCLUSIONS: Results obtained in our study by using the LEO Baby stent for balloon-then-stent and single- or dual-stent-assisted coiling of complex and distally located intracranial aneurysms are encouraging. Incomplete or inadequate opening of the device is a potential cause of laminar blood flow alteration and thrombus formation.
BACKGROUND AND PURPOSE: We report our preliminary results in terms of safety and efficacy in using the low-profile LEO Baby stent for the treatment of large-neck and complex intracranial aneurysms with balloon-then-stent-assisted coiling and single- or dual-stent-assisted coiling. MATERIALS AND METHODS: Clinical and radiologic data of all consecutive patients treated at our institution from September 2012 to October 2013 for an intracranial aneurysm by using a LEO Baby stent were retrospectively analyzed. Immediate and midterm clinical and anatomic follow-up of each patient is reported. RESULTS: Twenty-nine patients with 29 aneurysms were treated with LEO Baby stents at our institution. The mean age of patients was 48 years; 20 patients were women (71%). One patient was treated in the acute phase of a subarachnoid hemorrhage. In 8 procedures, a double-lumen-catheter balloon was used for balloon-then-stent-assisted coiling. In 3 cases, a LEO Baby stent was used in a Y-, T-, and telescopic dual-stent configuration. In 18 cases, a single LEO Baby stent was used. In 2 cases, technical failure to deploy the stent resulted in acute parent artery thrombosis. In 3 further cases, thromboembolic complications occurred intraoperatively. MR imaging and angiographic midterm follow-up showed complete aneurysm occlusion for 96% of the followed patients (27/29). Clinical outcome was favorable for all patients followed up. CONCLUSIONS: Results obtained in our study by using the LEO Baby stent for balloon-then-stent and single- or dual-stent-assisted coiling of complex and distally located intracranial aneurysms are encouraging. Incomplete or inadequate opening of the device is a potential cause of laminar blood flow alteration and thrombus formation.
Authors: David Fiorella; Felipe C Albuquerque; Vivek R Deshmukh; Henry H Woo; Peter A Rasmussen; Thomas J Masaryk; Cameron G McDougall Journal: Neurosurgery Date: 2006-08 Impact factor: 4.654
Authors: Hannes Luecking; Tobias Struffert; Philipp Goelitz; Tobias Engelhorn; Sebastian Brandner; Joji B Kuramatsu; Stefan Lang; Manuel Schmidt; Arnd Doerfler Journal: Clin Neuroradiol Date: 2020-05-08 Impact factor: 3.649
Authors: Peter Voigt; Stefan Schob; Robert Jantschke; Ulf Nestler; Matthias Krause; David Weise; Donald Lobsien; Karl-Titus Hoffmann; Ulf Quäschling Journal: Front Neurol Date: 2017-11-14 Impact factor: 4.003
Authors: Edgar A Samaniego; Aldo A Mendez; Thanh N Nguyen; Vladimir Kalousek; Waldo R Guerrero; Sudeepta Dandapat; Guilherme Dabus; Italo Linfante; Ameer E Hassan; Alexander Drofa; Evgueni Kouznetsov; David Leedahl; David Hasan; Alberto Maud; Santiago Ortega-Gutierrez Journal: Interv Neurol Date: 2018-04-03