Literature DB >> 26269609

A Feasibility Study of a Tilted Head Position in Helical Tomotherapy for Fractionated Stereotactic Radiotherapy of Intracranial Malignancies.

Yoonsun Chung1, Hong In Yoon2, Jin Sook Ha2, Seijoon Kim2, Ik Jae Lee3.   

Abstract

Herein, we evaluated the feasibility of placing patients in a tilted head position as part of routine clinical practice for fractionated stereotactic radiotherapy (FSRT) of intracranial tumors using helical tomotherapy (HT), by assessing its dosimetric benefit and setup accuracy. We reviewed treatment plans of four cases that were to receive FSRT for brain lesions in normal and head-tilted positions. These patients underwent two computed tomography (CT) scans: first in the normal supine position and then in the supine position with the head tilted at a 458 angle. Two separate HT plans for each position were generated in these four patients, using the same planning parameters. Plans were compared for target conformity and dose homogeneity. Maximum and average doses to critical organs, including normal brain, brain stem, optic chiasm, optic nerves, and the eyes, were considered. To evaluate setup accuracy, patient movement during treatment was assessed by post-treatment megavoltage CT scans. Both HT plans achieved similar conformal and homogeneous dose coverage to the target. Head-tilted HT delivered lower average and maximum doses to critical organs in the cases where the tumor was located on the same plane with critical organs, particularly when they were not directly attached. Placement in the head-tilted position without a mouthpiece allowed for increased patient movement during treatment, while use of a mouthpiece reduced patient movement to even less than that observed for normal setup in the supine position. This pilot study showed that placement in a tilted head position for FSRT of intracranial tumors using HT may be of clinical use, but depends on the tumor location.
© The Author(s) 2014.

Entities:  

Keywords:  Fractionated stereotactic radiotherapy; Helical tomotherapy; Intracranial tumors; Patient positioning

Mesh:

Year:  2015        PMID: 26269609     DOI: 10.1177/1533034614500420

Source DB:  PubMed          Journal:  Technol Cancer Res Treat        ISSN: 1533-0338


  2 in total

1.  Practical aspects of the application of helical tomotherapy for craniospinal irradiation.

Authors:  Joongyo Lee; Euidam Kim; Nalee Kim; Hwa Kyung Byun; Chang-Ok Suh; Yoonsun Chung; Hong In Yoon
Journal:  Sci Rep       Date:  2021-03-17       Impact factor: 4.379

2.  Development of a Tongue Immobilization Device Using a 3D Printer for Intensity Modulated Radiation Therapy of Nasopharyngeal Cancer Patients.

Authors:  Sang Gyu Ju; Yong Chan Ahn; Yeong-Bi Kim; Seung Gyu Park; Yoo-Mi Choi; Cho Hee Na; Chae-Seon Hong; Dongryul Oh; Dong Yeol Kwon; Cheol Chong Kim; Dong Hyeon Kim
Journal:  Cancer Res Treat       Date:  2020-09-15       Impact factor: 4.679

  2 in total