Atmospheric-pressure chemical ionization tandem mass spectrometry (APGC/MS/MS) an alternative to high-resolution mass spectrometry (HRGC/HRMS) for the determination of dioxins.

Bert van Bavel1, Dawei Geng1, Laura Cherta2, Jaime Nácher-Mestre2, Tania Portolés2, Manuela Ábalos1,3, Jordi Sauló3, Esteban Abad3, Jody Dunstan4, Rhys Jones4, Alexander Kotz5, Helmut Winterhalter5, Rainer Malisch5, Wim Traag6, Jessika Hagberg1, Ingrid Ericson Jogsten1, Joaquim Beltran2, Félix Hernández2.   

Abstract

The use of a new atmospheric-pressure chemical ionization source for gas chromatography (APGC) coupled with a tandem quadrupole mass spectrometry (MS/MS) system, as an alternative to high-resolution mass spectrometry (HRMS), for the determination of PCDDs/PCDFs is described. The potential of using atmospheric-pressure chemical ionization (APCI) coupled to a tandem quadrupole analyzer has been validated for the identification and quantification of dioxins and furans in different complex matrices. The main advantage of using the APCI source is the soft ionization at atmospheric pressure, which results in very limited fragmentation. APCI mass spectra are dominated by the molecular ion cluster, in contrast with the high energy ionization process under electron ionization (EI). The use of the molecular ion as the precursor ion in MS/MS enhances selectivity and, consequently, sensitivity by increasing the signal-to-noise ratios (S/N). For standard solutions of 2,3,7,8-TCDD, injections of 10 fg in the splitless mode on 30- or 60-m-length, 0.25 mm inner diameter (id), and 25 μm film thickness low-polarity capillary columns (DB5MS type), signal-to-noise (S/N) ratios of >10:1 were routinely obtained. Linearity was achieved in the region (correlation coefficient of r(2) > 0.998) for calibration curves ranging from 100 fg/μL to 1000 pg/μL. The results from a wide variety of complex samples, including certified and standard reference materials and samples from several QA/QC studies, which were previously analyzed by EI HRGC/HRMS, were compared with the results from the APGC/MS/MS system. Results between instruments showed good agreement both in individual congeners and toxic equivalence factors (TEQs). The data show that the use of APGC in combination with MS/MS for the analysis of dioxins has the same potential, in terms of sensitivity and selectivity, as the traditional HRMS instrumentation used for this analysis. However, the APCI/MS/MS system, as a benchtop system, is much easier to use.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 26267710     DOI: 10.1021/acs.analchem.5b02264

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  6 in total

Review 1.  Quantitative mass spectrometry methods for pharmaceutical analysis.

Authors:  Glenn Loos; Ann Van Schepdael; Deirdre Cabooter
Journal:  Philos Trans A Math Phys Eng Sci       Date:  2016-10-28       Impact factor: 4.226

2.  Determination of 2,3,7,8-tetrachlorodibenzo-p-dioxin based on SERS substrates composited of Au nanoparticles supported on twice-oxidized graphene oxide.

Authors:  Jie Cheng; Mengdie Fan; Peilong Wang; Xiao-Ou Su
Journal:  Mikrochim Acta       Date:  2020-04-21       Impact factor: 5.833

3.  Analysis of Grape Volatiles Using Atmospheric Pressure Ionization Gas Chromatography Mass Spectrometry-Based Metabolomics.

Authors:  Manoj Ghaste; Fulvio Mattivi; Giuseppe Astarita; Vladimir Shulaev
Journal:  Methods Mol Biol       Date:  2022

Review 4.  Identification of small molecules using accurate mass MS/MS search.

Authors:  Tobias Kind; Hiroshi Tsugawa; Tomas Cajka; Yan Ma; Zijuan Lai; Sajjan S Mehta; Gert Wohlgemuth; Dinesh Kumar Barupal; Megan R Showalter; Masanori Arita; Oliver Fiehn
Journal:  Mass Spectrom Rev       Date:  2017-04-24       Impact factor: 10.946

5.  Atmospheric Pressure Chemical Ionization Gas Chromatography Mass Spectrometry for the Analysis of Selected Emerging Brominated Flame Retardants in Foods.

Authors:  Surong Lv; Yumin Niu; Jing Zhang; Bing Shao; Zhenxia Du
Journal:  Sci Rep       Date:  2017-03-10       Impact factor: 4.379

6.  Ascertaining Hydrogen-Abstraction Reaction Efficiencies of Halogenated Organic Compounds in Electron Impact Ionization Processes by Gas Chromatography-High-Resolution Mass Spectrometry.

Authors:  Caiming Tang; Jianhua Tan; Yujuan Fan; Xianzhi Peng
Journal:  ACS Omega       Date:  2020-04-08
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.