Literature DB >> 26266652

Resin Bonding to a Hybrid Ceramic: Effects of Surface Treatments and Aging.

F Campos, C S Almeida, M P Rippe, R M de Melo, L F Valandro, M A Bottino.   

Abstract

The aim of this study was to verify the effects of different surface treatments on the microtensile bond strength between resin cement and a hybrid ceramic. Thirty-two hybrid ceramic slices (8 × 10 × 3 mm) were produced and allocated among four groups according to the surface treatment: Cont = no treatment, HA = 10% hydrofluoric acid applied for 60 seconds, PA = 37% phosphoric acid applied for 60 seconds and CJ = air abrasion with silica particle coated alumina (Cojet Sand, 3M ESPE, 30 μm/2.8 bar). As a control group, eight blocks of feldspathic ceramic (8 × 10 × 3 mm) were etched by hydrofluoric acid for 60 seconds (VMII). After the surface treatments, the ceramic slices were silanized (except the Cont group) and adhesively cemented to composite resin blocks (8 × 10 × 3 mm ) with a load of 750 g (polymerized for 40 seconds each side). The cemented blocks were cut into beams (bonded surface area of ∼1 mm(2)). Half of the beams were aged (thermocycling of 5°C-55°C/6000 cycles + water storage at 37°C/60 days), and the other half were tested immediately after being cut. Data were analyzed by Kruskal-Wallis and Dunn tests (non-aged groups) and by one-way analysis of variance and Tukey test (aged groups; α=0.05%). The mode of failure was classified by stereomicroscopy. The surface treatment significantly affected the bond strength in each set of groups: non-aged (p=0.001) and aged (p=0.001). Before being aged, samples in the CJ, HA, and PA groups achieved the highest bond strength values. However, after being aged, only those in the HA group remained with the highest bond strength values. Adhesive failure was found most often. In conclusion, hydrofluoric acid etching should be used for surface conditioning of the studied hybrid ceramic.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 26266652     DOI: 10.2341/15-057-L

Source DB:  PubMed          Journal:  Oper Dent        ISSN: 0361-7734            Impact factor:   2.440


  10 in total

1.  In Vitro Evaluation of the Effect of Different Surface Treatments of a Hybrid Ceramic on the Microtensile Bond Strength to a Luting Resin Cement.

Authors:  Fariba Motevasselian; Zahra Amiri; Nasim Chiniforush; Mansoreh Mirzaei; Van Thompson
Journal:  J Lasers Med Sci       Date:  2019-10-01

Review 2.  Cement selection criteria for full coverage restorations: A comprehensive review of literature.

Authors:  Safoura Ghodsi; Sarah Arzani; Mina Shekarian; MohammadMostafa Aghamohseni
Journal:  J Clin Exp Dent       Date:  2021-11-01

Review 3.  Effectiveness of current adhesive systems when bonding to CAD/CAM indirect resin materials: A review of 32 publications.

Authors:  Atsushi Mine; Tomoshige Kabetani; Asuka Kawaguchi-Uemura; Mami Higashi; Yuko Tajiri; Ryosuke Hagino; Dai Imai; Masahiro Yumitate; Shintaro Ban; Mariko Matsumoto; Hirofumi Yatani
Journal:  Jpn Dent Sci Rev       Date:  2018-11-23

4.  Effect of surface treatments and universal adhesive application on the microshear bond strength of CAD/CAM materials.

Authors:  Soner Şişmanoğlu; Aliye Tuğçe Gürcan; Zuhal Yıldırım-Bilmez; Rana Turunç-Oğuzman; Burak Gümüştaş
Journal:  J Adv Prosthodont       Date:  2020-02-20       Impact factor: 1.904

5.  Effect of Bonding Protocols on the Performance of Luting Agents Applied to CAD-CAM Composites.

Authors:  Bruna Hilgemberg; Fabiana Suelen Figuerêdo de Siqueira; Andres Felipe Millan Cardenas; Josiane Loch Ribeiro; Andrés Dávila-Sánchez; Salvatore Sauro; Alessandro Dourado Loguercio; Cesar Augusto Galvao Arrais
Journal:  Materials (Basel)       Date:  2022-08-31       Impact factor: 3.748

6.  Microtensile bond strength of CAD/CAM-fabricated polymer-ceramics to different adhesive resin cements.

Authors:  Leyla Sadighpour; Farideh Geramipanah; Zahra Ghasri; Mehrnoosh Neshatian
Journal:  Restor Dent Endod       Date:  2018-09-03

7.  A Comparative Study on the Mechanical Properties of a Polymer-Infiltrated Ceramic-Network Material Used for the Fabrication of Hybrid Abutment.

Authors:  Salim Ongun; Sevcan Kurtulmus-Yilmaz; Gökçe Meriç; Mutahhar Ulusoy
Journal:  Materials (Basel)       Date:  2018-09-11       Impact factor: 3.623

8.  Effect of universal adhesives on microtensile bond strength to hybrid ceramic.

Authors:  Mohamed M Awad; Lamees Albedaiwi; Ahmed Almahdy; Rawaiz Khan; Nick Silikas; Muhanad M Hatamleh; Fahad M Alkhtani; Ali Alrahlah
Journal:  BMC Oral Health       Date:  2019-08-06       Impact factor: 2.757

9.  Marginal gap and fracture resistance of CAD/CAM ceramill COMP and cerasmart endocrowns for restoring endodontically treated molars bonded with two adhesive protocols: an in vitro study.

Authors:  Israa Atif Kassem; Ibrahim Elsebai Farrag; Samir Mahmoud Zidan; Jylan Fouad ElGuindy; Reham Said Elbasty
Journal:  Biomater Investig Dent       Date:  2020-02-25

10.  Evaluation of the Surface Characteristics of Dental CAD/CAM Materials after Different Surface Treatments.

Authors:  Konstantinos Papadopoulos; Kimon Pahinis; Kyriaki Saltidou; Dimitrios Dionysopoulos; Effrosyni Tsitrou
Journal:  Materials (Basel)       Date:  2020-02-22       Impact factor: 3.623

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.