Literature DB >> 26265403

Accuracy of CT-based patient-specific guides for total knee arthroplasty in patients with post-traumatic osteoarthritis.

M G M Schotanus1, E H van Haaren2, R P M Hendrickx3, E J P Jansen4, N P Kort5.   

Abstract

Published clinical trials who studied the accuracy of patient-specific guides (PSG) for total knee arthroplasty exclude patients with articular deformity of the knee joint. We prospectively analysed a series of 30 patients with post-traumatic osteoarthritis of the knee joint with use of PSG. At 1 year post-operative, the achieved biomechanical (HKA) axis and varus/valgus of the femur and tibia components were measured on anterior-posterior (AP) long-standing weight-bearing radiographs. Flexion/extension of the femoral and AP slope of the tibia component was measured on standard lateral radiographs. Percentages >3° deviation of the pre-operative planned HKA axis and individual implant components were considered as outliers. Approved and used implant size, median blood loss (ml) and operation time (min) were obtained from the operation records. Pre- and 1-year post-operative patient-reported outcome measures (PROMs) were performed. Eighty-three per cent of the patients had a HKA axis restored <3° of the pre-operative planned alignment. Varus/valgus outliers were 0.0 and 6.7 % for the femoral and tibial components, respectively. Percentages of outliers of flexion/extension were 36.7 % for the femoral component and 10.0 % for the AP slope of the tibial component. Median blood loss was 300 ml (50-700), while operation time was 67 min (44-144). In 20 % of all cases, the approved implant size was changed into one size smaller. One-year post-operative PROMs improved significantly. We conclude that the accuracy of CT-based PSG is not impaired in patients with post-traumatic osteoarthritis and this modality can restore biomechanical limb alignment.

Entities:  

Keywords:  CT-based; Knee alignment; Patient-specific guides; Post-traumatic osteoarthritis; Retained metal hardware; Total knee arthroplasty

Mesh:

Year:  2015        PMID: 26265403     DOI: 10.1007/s00590-015-1677-3

Source DB:  PubMed          Journal:  Eur J Orthop Surg Traumatol        ISSN: 1633-8065


  32 in total

1.  Alignment in total knee arthroplasty. A comparison of computer-assisted surgery with the conventional technique.

Authors:  H Bäthis; L Perlick; M Tingart; C Lüring; D Zurakowski; J Grifka
Journal:  J Bone Joint Surg Br       Date:  2004-07

2.  Computer assisted orthopaedic surgery: present status and future perspectives.

Authors:  Kwok Sui Leun
Journal:  Chin Med J (Engl)       Date:  2010-11       Impact factor: 2.628

Review 3.  Does computer-assisted surgery improve postoperative leg alignment and implant positioning following total knee arthroplasty? A meta-analysis of randomized controlled trials?

Authors:  Tao Cheng; Song Zhao; Xiaochun Peng; Xianlong Zhang
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-07-06       Impact factor: 4.342

4.  The Chitranjan Ranawat award: is neutral mechanical alignment normal for all patients? The concept of constitutional varus.

Authors:  Johan Bellemans; William Colyn; Hilde Vandenneucker; Jan Victor
Journal:  Clin Orthop Relat Res       Date:  2012-01       Impact factor: 4.176

5.  Navigation-assisted total knee arthroplasty in knees with osteoarthritis due to extra-articular deformity.

Authors:  Fabio Catani; Vitantonio Digennaro; Andrea Ensini; Alberto Leardini; Sandro Giannini
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-07-29       Impact factor: 4.342

6.  Is TKA using patient-specific instruments comparable to conventional TKA? A randomized controlled study of one system.

Authors:  Yoon Whan Roh; Tae Woo Kim; Sahnghoon Lee; Sang Cheol Seong; Myung Chul Lee
Journal:  Clin Orthop Relat Res       Date:  2013-08-02       Impact factor: 4.176

7.  Computer-assisted total knee arthroplasty for arthritis with extra-articular deformity.

Authors:  Arun Mullaji; Gautam M Shetty
Journal:  J Arthroplasty       Date:  2009-07-04       Impact factor: 4.757

8.  Total knee arthroplasty with patient-specific instruments improves function and restores limb alignment in patients with extra-articular deformity.

Authors:  Emmanuel Thienpont; Frederic Paternostre; Martin Pietsch; Mahmoud Hafez; Stephen Howell
Journal:  Knee       Date:  2013-07-27       Impact factor: 2.199

9.  Total knee arthroplasty using computer-assisted navigation in patients with deformities of the femur and tibia.

Authors:  Gregg R Klein; Matthew S Austin; Eric B Smith; William J Hozack
Journal:  J Arthroplasty       Date:  2006-02       Impact factor: 4.757

10.  Patient-specific guide for revision of medial unicondylar knee arthroplasty to total knee arthroplasty: beneficial first results of a new operating technique performed on 10 patients.

Authors:  Bart Kerens; Bert Boonen; Martijn Schotanus; Nanne Kort
Journal:  Acta Orthop       Date:  2013-03-15       Impact factor: 3.717

View more
  3 in total

1.  Revision of partial knee to total knee arthroplasty with use of patient-specific instruments results in acceptable femoral rotation.

Authors:  Martijn G M Schotanus; Elke Thijs; B Boonen; B Kerens; B Jong; Nanne P Kort
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2017-08-07       Impact factor: 4.342

Review 2.  Favourable alignment outcomes with MRI-based patient-specific instruments in total knee arthroplasty.

Authors:  Martijn G M Schotanus; Elke Thijs; Marion Heijmans; Rein Vos; Nanne P Kort
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2017-07-11       Impact factor: 4.342

Review 3.  3D-printing techniques in a medical setting: a systematic literature review.

Authors:  Philip Tack; Jan Victor; Paul Gemmel; Lieven Annemans
Journal:  Biomed Eng Online       Date:  2016-10-21       Impact factor: 2.819

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.