Literature DB >> 26263044

Effects of stress relaxation in beta-titanium orthodontic loops: Part II.

Roberto S S Júnior1, Sergei G F R Caldas2, Lídia P Martins3, Renato P Martins4.   

Abstract

OBJECTIVE: To determine which regions of beta-titanium T-loop springs (TLSs) are more affected by the stress relaxation over a 12-week period.
MATERIALS AND METHODS: Fifty TLS were previously activated by concentrated bends and divided into five groups of 10 each according to their evaluation periods: immediate assessment (G0), 24 hours (G1), 48 hours (G2), 1 week (G3), and 12 weeks (G4). Groups 1 to 4 were mounted into a structure simulating a clinical situation. After the experimental periods, the springs were scanned for measurement of their angles and numbered from 1 to 9. A two-way analysis of variance was used to detect differences among the angles measured and differences caused by time and also to detect interactions between those two factors. Tukey's test was used to find differences among the groups.
RESULTS: Time influenced the angulations of the TLSs (P < .001). Tukey post hoc test showed that G0 (84.1°) presented a different profile, whereas G1 (90.2°), G2 (90.7°), and G3 (91.1°) had similar profiles among each other, with G4 (92.6°) showing a mean value different from all other groups. A significant interaction was detected between activation time and angular deformation in the TLSs (P < .01).
CONCLUSION: Stress relaxation was observed in the TLSs. It was greatest within 24 hours and gradually increased up to 12 weeks. Two regions were identified as responsible for the relaxation of the TLSs: one at the bend between the vertical extensions of the springs and the base arch and the other at the preactivation bends made in the base arch.

Entities:  

Keywords:  Biomechanics; Orthodontics; Titanium

Mesh:

Substances:

Year:  2015        PMID: 26263044     DOI: 10.2319/112614-846.1

Source DB:  PubMed          Journal:  Angle Orthod        ISSN: 0003-3219            Impact factor:   2.079


  2 in total

1.  Stability of beta-titanium T-loop springs preactivated by gradual curvature.

Authors:  Sergei Godeiro Fernandes Rabelo Caldas; Renato Parsekian Martins; Marcela Emílio de Araújo; Marília Regalado Galvão; Roberto Soares da Silva Júnior; Lídia Parsekian Martins
Journal:  Dental Press J Orthod       Date:  2017 Nov-Dec

2.  Effects of stress relaxation in beta-titanium cantilevers used in orthodontic mechanics.

Authors:  Helder B Jacob; Ariane S Gonzaga; Brittany Trinh; Erik T LE; Jeryl D English
Journal:  Dental Press J Orthod       Date:  2021-12-15
  2 in total