Literature DB >> 26256395

The Ex Vivo Eye Irritation Test as an alternative test method for serious eye damage/eye irritation.

Felix Spöler1, Oya Kray2, Stefan Kray1, Claudia Panfil2, Norbert F Schrage3.   

Abstract

Ocular irritation testing is a common requirement for the classification, labelling and packaging of chemicals (substances and mixtures). The in vivo Draize rabbit eye test (OECD Test Guideline 405) is considered to be the regulatory reference method for the classification of chemicals according to their potential to induce eye injury. In the Draize test, chemicals are applied to rabbit eyes in vivo, and changes are monitored over time. If no damage is observed, the chemical is not categorised. Otherwise, the classification depends on the severity and reversibility of the damage. Alternative test methods have to be designed to match the classifications from the in vivo reference method. However, observation of damage reversibility is usually not possible in vitro. Within the present study, a new organotypic method based on rabbit corneas obtained from food production is demonstrated to close this gap. The Ex Vivo Eye Irritation Test (EVEIT) retains the full biochemical activity of the corneal epithelium, epithelial stem cells and endothelium. This permits the in-depth analysis of ocular chemical trauma beyond that achievable by using established in vitro methods. In particular, the EVEIT is the first test to permit the direct monitoring of recovery of all corneal layers after damage. To develop a prediction model for the EVEIT that is comparable to the GHS system, 37 reference chemicals were analysed. The experimental data were used to derive a three-level potency ranking of eye irritation and corrosion that best fits the GHS categorisation. In vivo data available in the literature were used for comparison. When compared with GHS classification predictions, the overall accuracy of the three-level potency ranking was 78%. The classification of chemicals as irritating versus non-irritating resulted in 96% sensitivity, 91% specificity and 95% accuracy. 2015 FRAME.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 26256395     DOI: 10.1177/026119291504300306

Source DB:  PubMed          Journal:  Altern Lab Anim        ISSN: 0261-1929            Impact factor:   1.303


  4 in total

Review 1.  In vitro reconstructed 3D corneal tissue models for ocular toxicology and ophthalmic drug development.

Authors:  Yulia Kaluzhny; Mitchell Klausner
Journal:  In Vitro Cell Dev Biol Anim       Date:  2021-02-05       Impact factor: 2.416

2.  Development of a novel ex vivo equine corneal model.

Authors:  Todd L Marlo; Elizabeth A Giuliano; Ajay Sharma; Rajiv R Mohan
Journal:  Vet Ophthalmol       Date:  2016-07-29       Impact factor: 1.644

3.  An in vitro depth of injury prediction model for a histopathologic classification of EPA and GHS eye irritants.

Authors:  Stewart Lebrun; Yilu Xie; Sara Chavez; Roxanne Chan; James V Jester
Journal:  Toxicol In Vitro       Date:  2019-08-13       Impact factor: 3.500

4.  Defining corneal chemical burns: A novel exact and adjustable ocular model.

Authors:  Markus Glaudo; Claudia Panfil; Norbert F Schrage
Journal:  Toxicol Rep       Date:  2021-06-08
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.