Literature DB >> 26253503

Insights into the influence of the cooling profile on the reconstitution times of amorphous lyophilized protein formulations.

Karen E Beech1, James G Biddlecombe2, Christopher F van der Walle2, Lee A Stevens3, Sean P Rigby3, Jonathan C Burley1, Stephanie Allen4.   

Abstract

Lyophilized protein formulations must be reconstituted back into solution prior to patient administration and in this regard long reconstitution times are not ideal. The factors that govern reconstitution time remain poorly understood. The aim of this research was to understand the influence of the lyophilization cooling profile (including annealing) on the resulting cake structure and reconstitution time. Three protein formulations (BSA 50mg/ml, BSA 200mg/ml and IgG1 40mg/ml, all in 7% w/v sucrose) were investigated after cooling at either 0.5°C/min, or quench cooling with liquid nitrogen with/without annealing. Significantly longer reconstitution times were observed for the lower protein concentration formulations following quench cool. Porosity measurements found concomitant increases in the surface area of the porous cake structure but a reduction in total pore volume. We propose that slow reconstitution results from either closed pores or small pores impeding the penetration of water into the lyophilized cake.
Copyright © 2015 The Authors. Published by Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Annealing; Lyophilization; Mercury intrusion porosimetry; Monoclonal antibody; Quench cooling; Reconstitution

Mesh:

Substances:

Year:  2015        PMID: 26253503     DOI: 10.1016/j.ejpb.2015.07.029

Source DB:  PubMed          Journal:  Eur J Pharm Biopharm        ISSN: 0939-6411            Impact factor:   5.571


  3 in total

1.  Simulation, Fabrication and Analysis of Silver Based Ascending Sinusoidal Microchannel (ASMC) for Implant of Varicose Veins.

Authors:  Muhammad Javaid Afzal; Shahzadi Tayyaba; Muhammad Waseem Ashraf; M Khalid Hossain; M Jalal Uddin; Nitin Afzulpurkar
Journal:  Micromachines (Basel)       Date:  2017-09-14       Impact factor: 2.891

2.  The Influence of Moisture Content and Temperature on the Long-Term Storage Stability of Freeze-Dried High Concentration Immunoglobulin G (IgG).

Authors:  Arnold Duralliu; Paul Matejtschuk; Paul Stickings; Laura Hassall; Robert Tierney; Daryl R Williams
Journal:  Pharmaceutics       Date:  2020-03-27       Impact factor: 6.321

3.  Spin Freezing and Its Impact on Pore Size, Tortuosity and Solid State.

Authors:  Joris Lammens; Niloofar Moazami Goudarzi; Laurens Leys; Gust Nuytten; Pieter-Jan Van Bockstal; Chris Vervaet; Matthieu N Boone; Thomas De Beer
Journal:  Pharmaceutics       Date:  2021-12-09       Impact factor: 6.321

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.