Literature DB >> 26251554

Efficient generation of volatile cadmium species using Ti(III) and Ti(IV) and application to determination of cadmium by cold vapor generation inductively coupled plasma mass spectrometry (CVG-ICP-MS).

Zikri Arslan1, Vedat Yilmaz2, LaKeysha Rose1.   

Abstract

In this study, a highly efficient chemical vapor generation (CVG) approach is reported for determination of cadmium (Cd). Titanium (III) and titanium (IV) were investigated for the first time as catalytic additives along with thiourea, L-cysteine and potassium cyanide (KCN) for generation of volatile Cd species. Both Ti(III) and Ti(IV) provided the highest enhancement with KCN. The improvement with thiourea was marginal (ca. 2-fold), while L-cysteine enhanced signal slightly only with Ti(III) in H2SO4. Optimum CVG conditions were 4% (v/v) HCl + 0.03 M Ti(III) + 0.16 M KCN and 2% (v/v) HNO3 + 0.03 M Ti(IV) + 0.16 M KCN with a 3% (m/v) NaBH4 solution. The sensitivity was improved about 40-fold with Ti(III) and 35-fold with Ti(IV). A limit of detection (LOD) of 3.2 ng L-1 was achieved with Ti(III) by CVG-ICP-MS. The LOD with Ti(IV) was 6.4 ng L-1 which was limited by the blank signals in Ti(IV) solution. Experimental evidence indicated that Ti(III) and Ti(IV) enhanced Cd vapor generation catalytically; for best efficiency mixing prior to reaction with NaBH4 was critical. The method was highly robust against the effects of transition metal ions. No significant suppression was observed in the presence of Co(II), Cr(III), Cu(II), Fe(III), Mn(II), Ni(II) and Zn(II) up to 1.0 μg mL-1. Among the hydride forming elements, no interference was observed from As(III) and Se(IV) at 0.5 μg mL-1 level. The depressive effects from Pb(II) and Sb(III) were not significant at 0.1 μg mL-1 while those from Bi(III) and Sn(II) were marginal. The procedures were validated with determination of Cd by CVG-ICP-MS in a number certified reference materials, including Nearshore seawater (CASS-4), Bone ash (SRM 1400), Dogfish liver (DOLT-4), Mussel tissue (SRM 2976) and Domestic Sludge (SRM 2781).

Entities:  

Keywords:  Cadmium; Chemical vapor generation; Inductively coupled plasma mass spectrometry; Titanium (III); Titanium (IV)

Year:  2015        PMID: 26251554      PMCID: PMC4522934          DOI: 10.1016/j.microc.2015.06.006

Source DB:  PubMed          Journal:  Microchem J        ISSN: 0026-265X            Impact factor:   4.821


  12 in total

1.  Generation of atomic and molecular cadmium species from aqueous media.

Authors:  Yong-Lai Feng; Ralph E Sturgeon; Joseph W Lam
Journal:  Anal Chem       Date:  2003-02-01       Impact factor: 6.986

2.  On-line chemical vapour generation of cadmium in the presence of hexacyanochromate(III) for determination by inductively coupled plasma mass spectrometry (ICP-MS).

Authors:  Vedat Yilmaz; Lakeysha Rose; Zikri Arslan; Maria D Little
Journal:  J Anal At Spectrom       Date:  2012-11-01       Impact factor: 4.023

3.  Hydride generation atomic absorption spectrometry with different flow systems and in-atomizer trapping for determination of cadmium in water and urine-overview of existing data on cadmium vapour generation and evaluation of critical parameters.

Authors:  Leonardo Lampugnani; Claudia Salvetti; Dimiter L Tsalev
Journal:  Talanta       Date:  2003-12-04       Impact factor: 6.057

4.  An automated on-line minicolumn preconcentration cold vapour atomic absorption spectrometer: application to determination of cadmium in water samples.

Authors:  Serkan Sahan; Uğur Sahin
Journal:  Talanta       Date:  2011-11-28       Impact factor: 6.057

5.  Cyanovanadate(III) complexes as novel additives for efficient generation of volatile cadmium species in complex samples prior to determinations by inductively coupled plasma mass spectrometry (ICP-MS).

Authors:  Vedat Yilmaz; Zikri Arslan; LaKeysha Rose; Maria D Little
Journal:  Talanta       Date:  2013-10-15       Impact factor: 6.057

6.  Determination of cadmium in environmental samples by hydride generation with in situ concentration and atomic absorption detection.

Authors:  H Matusiewicz; M Kopras; R E Sturgeon
Journal:  Analyst       Date:  1997-04       Impact factor: 4.616

7.  Determination of cadmium by flow injection-chemical vapor generation-atomic absorption spectrometry.

Authors:  C Vargas-Razo; J F Tyson
Journal:  Fresenius J Anal Chem       Date:  2000-01

8.  Ultratrace determination of cadmium by cold vapor atomic absorption spectrometry after preconcentration with a simplified cloud point extraction methodology.

Authors:  Jamshid L Manzoori; Hossein Abdolmohammad-Zadeh; Mohammad Amjadi
Journal:  Talanta       Date:  2006-06-08       Impact factor: 6.057

9.  Vapor generation atomic absorption spectrometric determination of cadmium in environmental samples with in-line anion exchange separation.

Authors:  Samuel B Adeloju; Yanlin Zhang
Journal:  Anal Chem       Date:  2009-06-01       Impact factor: 6.986

10.  Chemical vapor generation of arsane in the presence of L-cysteine. Mechanistic studies and their analytical feedback.

Authors:  Emanuela Pitzalis; Delè Ajala; Massimo Onor; Roberto Zamboni; Alessandro D'Ulivo
Journal:  Anal Chem       Date:  2007-07-18       Impact factor: 6.986

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.