Literature DB >> 18969233

Hydride generation atomic absorption spectrometry with different flow systems and in-atomizer trapping for determination of cadmium in water and urine-overview of existing data on cadmium vapour generation and evaluation of critical parameters.

Leonardo Lampugnani1, Claudia Salvetti, Dimiter L Tsalev.   

Abstract

An overview of literature data on vapour generation techniques for cadmium and comparison with own experiments by means of several different types of hydride generation-electrothermal atomic absorption spectrometric systems (HG-ETAAS) (batch, semi-batch (SB), continuous-flow (CF) and flow-injection (FI) as well as different gas-liquid separators (GLS) exhibits apparent variations and inconsistency. However, if data for optimal chemical conditions are re-plotted in another coordinates: C(HCl) (mol l(-1)) vs. the ratio of reductant-to-acid molar input rates (i.e. millimoles per minute), [BH(4)(-)]:[H(+)], much better consistency of data is revealed: more than half of data are clustered around 0.2-0.3 mol l(-1) HCl which appears an optimal acidity at moderate BH(4)(-) concentrations; the tetrahydroborate molar input rates should always be in excess versus the H(+) molar input rates (1.1 to tenfold); relatively high flow rates of argon purge gas are required (>/=120 ml min(-1)); special attention to the blank control at ng l(-1) levels as well as to the construction of gas-liquid separator and vapour transfer lines should be paid. 'Milder' conditions for HG could be provided with some of the examined systems and GLSs, thus minimizing reagent consumption, blanks, vigorous reactions, foaming, aerosol production and drift in measurements: e.g. 0.4 mol l(-1) HCl-3% m/v NaBH(4) with the semi-batch system and 0.25 mol l(-1) HCl-2% m/v NaBH(4) in continuous flow mode. Experimental system is based on the Transversely Heated Graphite Atomizer coupled with flow injection system FIAS 400. Integrated platforms are treated for permanent modification with Zr (110 mug) or W (240 mug) and then with Ir (8 mug). Temperatures of trapping, pyrolysis and atomization are 350, 500 and 1300 degrees C, respectively. The best overall efficiency of HG, transportation and trapping is 41%. The characteristic mass for peak area measurements is m(o)=2.8 pg and the limit of detection is 0.002 mug l(-1). The long-term stability of characteristic mass (within-day, 8 h) is m(o)=2.8+/-0.1 pg (R.S.D. 4.0%, n=8), whereas the corresponding between-day figures (1 mo) are m(o)=2.8+/-0.2 pg (R.S.D. 6.6%, n=6). The linear range is 0.002-0.12 mug l(-1) with a sample loop of 1.8 ml, being strongly impaired with smaller sample volumes in FI mode. The sample throughput rate is 10 h(-1) with the semi-batch system. Applications to real human and bovine urine samples and CRMs of sea water (CASS-3), river water (SLRS-1 and SLRS-3) and urine (SRM 2670) are presented.

Entities:  

Year:  2003        PMID: 18969233     DOI: 10.1016/S0039-9140(03)00324-2

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  4 in total

1.  On-line chemical vapour generation of cadmium in the presence of hexacyanochromate(III) for determination by inductively coupled plasma mass spectrometry (ICP-MS).

Authors:  Vedat Yilmaz; Lakeysha Rose; Zikri Arslan; Maria D Little
Journal:  J Anal At Spectrom       Date:  2012-11-01       Impact factor: 4.023

2.  Cyanovanadate(III) complexes as novel additives for efficient generation of volatile cadmium species in complex samples prior to determinations by inductively coupled plasma mass spectrometry (ICP-MS).

Authors:  Vedat Yilmaz; Zikri Arslan; LaKeysha Rose; Maria D Little
Journal:  Talanta       Date:  2013-10-15       Impact factor: 6.057

3.  Efficient generation of volatile cadmium species using Ti(III) and Ti(IV) and application to determination of cadmium by cold vapor generation inductively coupled plasma mass spectrometry (CVG-ICP-MS).

Authors:  Zikri Arslan; Vedat Yilmaz; LaKeysha Rose
Journal:  Microchem J       Date:  2015-11-01       Impact factor: 4.821

4.  Toxic Effect of Cadmium Assay in Contaminated Soil Earthworm Cell Using Modified Sensor.

Authors:  Suw Young Ly; Lee Kyung; Chae Hwa Kim; Roma Seo; Soo Youn Lee; Lina Kim; Su Min Chae; Sung Wook Choi; Ji Yoon Kim
Journal:  Toxicol Res       Date:  2015-06
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.