Literature DB >> 26244855

Factors Affecting Dental Implant Stability Measured Using the Ostell Mentor Device: A Systematic Review.

Francisco J Manzano-Moreno1, Francisco J Herrera-Briones, Tala Bassam, Manuel F Vallecillo-Capilla, Candela Reyes-Botella.   

Abstract

OBJECTIVES: The aim of this study was to review the literature on factors that may affect dental implant stability as measured with the Ostell mentor device.
MATERIALS AND METHODS: A systematic search of the literature was performed in Pubmed, Scopus, and Cochrane databases using dental implants, stability, and resonance frequency analysis as key words.
RESULTS: The most relevant randomized controlled trials and clinical trials (n = 39) were selected from among 264 articles.
CONCLUSIONS: Many factors can affect dental implant stability as measured with the Ostell mentor device. This may be a useful instrument for deciding the timing of implant loading, but additional research is required to establish the reliability and predictability of resonance frequency analysis for the future osseointegration of dental implants, which remains controversial.

Mesh:

Substances:

Year:  2015        PMID: 26244855     DOI: 10.1097/ID.0000000000000308

Source DB:  PubMed          Journal:  Implant Dent        ISSN: 1056-6163            Impact factor:   2.454


  7 in total

1.  The Use of Cone Beam Computed Tomography in Assessing the Insertion of Bone Conduction Hearing Implants.

Authors:  Tim George Ate Calon; Martin Lars Johansson; Elske Larissa van den Burg; Anna Maria Louisa Janssen; Marc van Hoof; Robert Jan Stokroos
Journal:  Front Surg       Date:  2017-07-24

2.  Effects of smoking on the bone alkaline phosphatase in peri-implant crevicular fluid and implant stability quotient around implants before loading.

Authors:  Gulay Tuter; Arzu Zeynep Yildirim; Ayse Nurcan Duman; Behruz Aliyev; Aysegul Atak-Yucel; Nihan Oruklu; Elifcan Kivrak
Journal:  Odontology       Date:  2022-01-06       Impact factor: 2.885

3.  A Radiographic and Clinical Comparison of Immediate vs. Early Loading (4 Weeks) of Implants with a New Thermo-Chemically Treated Surface: A Randomized Clinical Trial.

Authors:  Matteo Albertini; Federico Herrero-Climent; Carmen María Díaz-Castro; Jose Nart; Ana Fernández-Palacín; José Vicente Ríos-Santos; Mariano Herrero-Climent
Journal:  Int J Environ Res Public Health       Date:  2021-01-29       Impact factor: 3.390

Review 4.  Autogenous teeth used for bone grafting: A systematic review.

Authors:  P Gual-Vaqués; C Polis-Yanes; A Estrugo-Devesa; R Ayuso-Montero; A Mari-Roig; J López-López
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2018-01-01

5.  Relationship between cortical bone thickness and implant stability at the time of surgery and secondary stability after osseointegration measured using resonance frequency analysis.

Authors:  Kenko Tanaka; Irena Sailer; Ryosuke Iwama; Kensuke Yamauchi; Shinnosuke Nogami; Nobuhiro Yoda; Tetsu Takahashi
Journal:  J Periodontal Implant Sci       Date:  2018-12-27       Impact factor: 2.614

6.  Minimally Invasive Ponto Surgery Versus the Linear Incision Technique With Soft Tissue Preservation for Bone Conduction Hearing Implants: A Multicenter Randomized Controlled Trial.

Authors:  Tim G A Calon; Martin L Johansson; Arthur J G de Bruijn; Herbert van den Berge; Mariet Wagenaar; Edwin Eichhorn; Miranda M L Janssen; Janny R Hof; Jan-Wouter Brunings; Manuela A Joore; Sofia Jonhede; Joost van Tongeren; Marcus Holmberg; Robert-Jan Stokroos
Journal:  Otol Neurotol       Date:  2018-08       Impact factor: 2.311

7.  The Effects of Polyphenol, Tannic Acid, or Tannic Acid in Combination with Pamidronate on Human Osteoblast Cell Line Metabolism.

Authors:  Hermizi Hapidin; Nor Munira Hashim; Mohamad Zahid Kasiram; Hasmah Abdullah
Journal:  Molecules       Date:  2022-01-11       Impact factor: 4.411

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.